Decreasing the interference of visual-based P300 BCI using facial expression changes

被引:0
作者
Jin, Jing [1 ]
Zhang, Yu [1 ]
Wang, Xingyu [1 ]
Daly, Ian [2 ]
Cichocki, Andrzej [3 ]
机构
[1] East China Univ Sci & Technol, Minist Educ, Key Lab Adv Control & Optimizat Chem Proc, Shanghai 200237, Peoples R China
[2] Univ Reading, Sch Syst Engn, Brain Embodiment Lab, Reading RG6 6AY, Berks, England
[3] RIEKN, Brain Sci Inst, Lab Adv Brain Signal Proc, Wako, Saitama 3510198, Japan
来源
2014 11TH WORLD CONGRESS ON INTELLIGENT CONTROL AND AUTOMATION (WCICA) | 2014年
基金
中国国家自然科学基金;
关键词
Brain computer interface; face expression change; P300; BRAIN-COMPUTER INTERFACE; CLASSIFICATION; COMPONENTS;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Interferences from the spatially adjacent nontarget stimuli evoke ERPs during non-target sub-trials and lead to false positives. This phenomenon is commonly seen in visual attention based BCIs and affects the performance of BCI system. Although, users or subjects tried to focus on the target stimulus, they still could not help being affected by conspicuous changes of the stimuli (flashes or presenting images) which were adjacent to the target stimulus. In view of this case, the aim of this study is to reduce the adjacent interference using new stimulus presentation pattern based on facial expression changes. Positive facial expressions can be changed to negative facial expressions by minor changes to the original facial image. Although the changes are minor, the contrast will be big enough to evoke strong ERPs. In this paper, two different conditions (Pattern_1, Pattern_2) were used to compare across objective measures such as classification accuracy and information transfer rate as well as subjective measures. Pattern_1 was a "flash-only" pattern and Pattern_2 was a facial expression change of a dummy face. In the facial expression change patterns, the background is a positive facial expression and the stimulus is a negative facial expression. The results showed that the interferences from adjacent stimuli could be reduced significantly (P < 0.05) by using the facial expression change patterns. The online performance of the BCI system using the facial expression change patterns was significantly better than that using the "flash-only" patterns in terms of classification accuracy (p < 0.01), bit rate (p < 0.01), and practical bit rate (p < 0.01). Subjects reported that the annoyance and fatigue could be significantly decreased (p < 0.05) using the new stimulus presentation pattern presented in this paper.
引用
收藏
页码:2407 / 2411
页数:5
相关论文
共 50 条
  • [1] An Optimized BCI System based on P300 and Visual Mismatch Negativity
    Zhou, Sijie
    Jin, Jing
    Zhang, Yu
    Wang, Xingyu
    2015 2ND INTERNATIONAL CONFERENCE ON INFORMATION SCIENCE AND CONTROL ENGINEERING ICISCE 2015, 2015, : 622 - 625
  • [2] A Comparison of Navigation System Based on P300 BCI and SSVEP BCI
    Meng, Lijing
    Jin, Jing
    Wang, Xingyu
    PROCEEDINGS OF THE 2012 24TH CHINESE CONTROL AND DECISION CONFERENCE (CCDC), 2012, : 3703 - 3708
  • [3] Effects of Visual Attention on Tactile P300 BCI
    Chen, Zongmei
    Jin, Jing
    Daly, Ian
    Zuo, Cili
    Wang, Xingyu
    Cichocki, Andrzej
    COMPUTATIONAL INTELLIGENCE AND NEUROSCIENCE, 2020, 2020
  • [4] Orthogonal Extreme Learning Machine Based P300 Visual Event-Related BCI
    Kutlu, Yakup
    Yayik, Apdullah
    Yildirim, Esen
    Yildirim, Serdar
    NEURAL INFORMATION PROCESSING, PT II, 2015, 9490 : 284 - 291
  • [5] Cognitask: BCI system based on P300 for cognitive therapies
    Barreto, Facundo S.
    Carrere, L. Carolina
    Tabernig, Carolina B.
    IEEE LATIN AMERICA TRANSACTIONS, 2022, 20 (06) : 884 - 890
  • [6] Synchronous P300 Based BCI To Control Home Appliances
    Bentabet, Nebia
    Berrached, Nasr-Eddine
    PROCEEDINGS OF 2016 8TH INTERNATIONAL CONFERENCE ON MODELLING, IDENTIFICATION & CONTROL (ICMIC 2016), 2016, : 835 - 838
  • [7] P300 Detection based on Extraction and Classification in online BCI
    Hutagalung, Sutrisno Salomo
    Turnip, Arjon
    Munandar, Aris
    2013 3RD INTERNATIONAL CONFERENCE ON INSTRUMENTATION CONTROL AND AUTOMATION (ICA 2013), 2013, : 35 - 38
  • [8] An Asynchronous P300 BCI With SSVEP-Based Control State Detection
    Panicker, Rajesh C.
    Puthusserypady, Sadasivan
    Sun, Ying
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2011, 58 (06) : 1781 - 1788
  • [9] A new hybrid BCI paradigm based on P300 and SSVEP
    Wang, Minjue
    Daly, Ian
    Allison, Brendan Z.
    Jin, Jing
    Zhang, Yu
    Chen, Lanlan
    Wang, Xingyu
    JOURNAL OF NEUROSCIENCE METHODS, 2015, 244 : 16 - 25
  • [10] Efficiency of a BCI system in a visual P300 protocol with different stimulation intervals
    Quitadamo, Lucia Rita
    Abbafati, Manuel
    Saggio, Giovanni
    Cardarilli, Gian Carlo
    Marciani, Maria Grazia
    Bianchi, Luigi
    2009 1ST INTERNATIONAL CONFERENCE ON WIRELESS COMMUNICATION, VEHICULAR TECHNOLOGY, INFORMATION THEORY AND AEROSPACE & ELECTRONIC SYSTEMS TECHNOLOGY, VOLS 1 AND 2, 2009, : 616 - +