Evaluation of a multiplex flow immunoassay versus conventional assays in detecting autoantibodies in systemic lupus erythematosus

被引:8
作者
Au, Elaine Y. L. [1 ]
Ip, W. K. [1 ]
Lau, C. S. [2 ]
Chan, Y. T. [1 ]
机构
[1] Queen Mary Hosp, Dept Pathol, Div Clin Immunol, Pokfulam, Hong Kong, Peoples R China
[2] Univ Hong Kong, Dept Med, Div Rheumatol & Clin Immunol, Pokfulam, Hong Kong, Peoples R China
关键词
EXTRACTABLE NUCLEAR ANTIGENS; ANTINUCLEAR ANTIBODIES; CLINICAL-SIGNIFICANCE; ANA SCREEN; SERA; IMMUNOFLUORESCENCE; RHEUMATOLOGY; DIAGNOSIS; DAMAGE; DNA;
D O I
10.12809/hkmj177007
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Conventional diagnostic assays are being replaced with automated multiplex assays, but their performance needs to be evaluated. We compared a multiplex flow immunoassay with conventional techniques in the detection of antinuclear antibodies (ANAs) and antibodies to specific extractable nuclear antigens (ENAs) in serum samples from patients with systemic lupus erythematosus. Methods: A total of 140 consecutive Chinese patients with systemic lupus erythematosus and 41 healthy controls were included. The automated BioPlex 2200 ANA Screen assay (Bio-Rad Laboratories, Hercules [CA], US) was compared with indirect immunofluorescence. In addition, use of BioPlex 2200 to detect anti-ENA antibodies was compared with in-house assays of countercurrent immunoelectrophoresis (CIEP), enzyme-linked immunosorbent assay (ELISA), and line blot. Results: The sensitivity and specificity of BioPlex in detecting ANAs (91.4% and 95.1%, respectively) were comparable to those of indirect immunofluorescence (90.7% and 85.4%, respectively). Overall, BioPlex achieved the best agreement with ELISA in detecting anti-ENA antibodies: agreement was >90% for most antibody types (kappa=0.79-0.94). In contrast, agreement was poorest with CIEP, ranging from 85.6% (kappa=0.33) for anti-Sm antibodies to 93.9% (kappa=0.88) for anti-Ro antibodies. Overall, BioPlex and ELISA had the highest sensitivity, whereas CIEP had the highest specificity. In terms of disease association, anti-Sm detected by CIEP had the best positive predictive value and specificity for lupus nephritis. Conclusions: In a local lupus cohort, BioPlex showed comparable sensitivity to indirect immunofluorescence in detecting ANAs and comparable performance to ELISA in detecting anti-ENA antibodies. However, CIEP was the best method in terms of disease specificity.
引用
收藏
页码:261 / 269
页数:9
相关论文
共 50 条
  • [21] Autoantibodies against complement components in systemic lupus erythematosus - role in the pathogenesis and clinical manifestations
    Hristova, M. H.
    Stoyanova, V. S.
    [J]. LUPUS, 2017, 26 (14) : 1550 - 1555
  • [22] Cytokines in relation to autoantibodies before onset of symptoms for systemic lupus erythematosus
    Eriksson, C.
    Rantapaa-Dahlqvist, S.
    [J]. LUPUS, 2014, 23 (07) : 691 - 696
  • [23] High frequency of Smith autoantibodies in Omani patients with systemic lupus erythematosus
    Ali A. Al-Jabri
    Amal K. Al-Gahdani
    Ibtisam Al-Shuaili
    [J]. Rheumatology International, 2009, 30 : 51 - 56
  • [24] ANTI-DSDNA AND SM AUTOANTIBODIES IN SYSTEMIC LUPUS-ERYTHEMATOSUS
    MARTINEZCORDERO, E
    MARTINEZMIRANDA, E
    NEGRETEGARCIA, MC
    PADILLA, A
    LEON, DEA
    [J]. CLINICAL RHEUMATOLOGY, 1992, 11 (03) : 341 - 345
  • [25] Is systemic lupus erythematosus linked to Immunoglobulin G4 Autoantibodies?
    Wei, Shu-jun
    Xiong, Qian
    Yao, Huan
    He, Qing-man
    Yu, Peng-long
    [J]. HUMAN IMMUNOLOGY, 2024, 85 (04)
  • [26] Systematic review of infliximab-induced autoantibodies and systemic lupus erythematosus
    Pereira Vaz, Joao Luiz
    Ferreira Andrade, Carlos Augusto
    Pereira, Alessandra Cardoso
    Martins, Maria de Fatima M.
    Levy, Roger Abramino
    [J]. REVISTA BRASILEIRA DE REUMATOLOGIA, 2013, 53 (04) : 358 - 364
  • [27] Serological and clinical associations of autoantibodies in Chinese patients with new-onset systemic lupus erythematosus
    Gong, Muxue
    Dai, Li
    Xie, Zhuobei
    Hong, Dengxiao
    Li, Ning
    Fan, Xiaoyun
    Xie, Changhao
    [J]. SCIENTIFIC REPORTS, 2023, 13 (01)
  • [28] Utility of Antiphosphatidylserine/Prothrombin and IgA Antiphospholipid Assays in Systemic Lupus Erythematosus
    Akhter, Ehtisham
    Shums, Zakera
    Norman, Gary L.
    Binder, Walter
    Fang, Hong
    Petri, Michelle
    [J]. JOURNAL OF RHEUMATOLOGY, 2013, 40 (03) : 282 - 286
  • [29] A subset of systemic sclerosis but not of systemic lupus erythematosus is defined by isolated anti-Ku autoantibodies
    Cavazzana, I.
    Fredi, M.
    Taraborelli, M.
    Quinzanini, M.
    Tincani, A.
    Franceschini, F.
    [J]. CLINICAL AND EXPERIMENTAL RHEUMATOLOGY, 2013, 31 (02) : S118 - S121
  • [30] Microarray analysis of autoantibodies can identify future Systemic Lupus Erythematosus patients
    Brunekreef, Tammo E.
    Reteig, Leon C.
    Limper, Maarten
    Haitjema, Saskia
    Dias, Jorge
    Mathsson-Alm, Linda
    van Laar, Jacob M.
    Otten, Henny G.
    [J]. HUMAN IMMUNOLOGY, 2022, 83 (06) : 509 - 514