Excluding venous thromboembolism using point of care D-dimer tests in outpatients: a diagnostic meta-analysis

被引:99
作者
Geersing, G. J. [1 ]
Janssen, K. J. M. [1 ]
Oudega, R. [1 ]
Bax, L. [1 ,2 ]
Hoes, A. W. [1 ]
Reitsma, J. B. [3 ]
Moons, K. G. M. [1 ]
机构
[1] Univ Med Ctr Utrecht, Julius Ctr Hlth Sci & Primary Care, Utrecht, Netherlands
[2] Kitasato Univ, Kitasato Clin Res Ctr, Tokyo, Japan
[3] Univ Amsterdam, Acad Med Ctr, Dept Clin Epidemiol & Biostat, NL-1105 AZ Amsterdam, Netherlands
来源
BMJ-BRITISH MEDICAL JOURNAL | 2009年 / 339卷
关键词
DEEP-VEIN THROMBOSIS; SUSPECTED PULMONARY-EMBOLISM; CLINICAL PROBABILITY; PATIENT; SENSITIVITY; REVIEWS; ASSAY; BIAS;
D O I
10.1136/bmj.b2990
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective To review the evidence on the diagnostic accuracy of the currently available point of care D-dimer tests for excluding venous thromboembolism. Design Systematic review of research on the accuracy of point of care D-dimer tests, using bivariate regression to examine sources of variation and to estimate sensitivity and specificity. Data sources Studies on the diagnostic accuracy of point of care D-dimer tests published between January 1995 and September 2008 and available in either Medline or Embase. Review methods The analysis included studies that compared point of care D-dimer tests with predefined reference criteria for venous thromboembolism, enrolled consecutive outpatients, and allowed for construction of a 2 x 2 table. Results 23 studies (total number of patients 13 959, range in mean age 38-65 years, range of venous thromboembolism prevalence 4-51%) were included in the meta-analysis. The studies reported two qualitative point of care D-dimer tests (SimpliRED D-dimer (n=12) and Clearview Simplify D-dimer (n=7)) and two quantitative point of care D-dimer tests (Cardiac D-dimer (n=4) and Triage D-dimer (n=2)). Overall sensitivity ranged from 0.85 (95% confidence interval 0.78 to 0.90) to 0.96 (0.91 to 0.98) and overall specificity from 0.48 (0.33 to 0.62) to 0.74 (0.69 to 0.78). The two quantitative tests Cardiac D-dimer and Triage D-dimer scored most favourably. Conclusions In outpatients suspected of venous thromboembolism, point of care D-dimer tests can contribute important information and guide patient management, notably in low risk patients (that is, those patients with a low score on a clinical decision rule).
引用
收藏
页数:9
相关论文
共 26 条
  • [1] Does this patient have pulmonary embolism?
    Chunilal, SD
    Eikelboom, JW
    Attia, J
    Miniati, M
    Panju, AA
    Simel, DL
    Ginsberg, JS
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2003, 290 (21): : 2849 - 2858
  • [2] Embolus location affects the sensitivity of a rapid quantitative D-dimer assay in the diagnosis of pulmonary embolism
    De Monyé, W
    Sanson, BJ
    Mac Gillavry, MR
    Pattynama, PMT
    Büller, HR
    van den Berg-Huysmans, AA
    Huisman, MV
    [J]. AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2002, 165 (03) : 345 - 348
  • [3] A methodological review of how heterogeneity has been examined in systematic reviews of diagnostic test accuracy
    Dinnes, J
    Deeks, J
    Kirby, J
    Roderick, P
    [J]. HEALTH TECHNOLOGY ASSESSMENT, 2005, 9 (12) : 1 - +
  • [4] Dwamena B., 2007, MIDAS COMPUTATIONAL
  • [5] Combined use of rapid D-dimer testing and estimation of clinical probability in the diagnosis of deep vein thrombosis: systematic review
    Fancher, TL
    White, RH
    Kravitz, RL
    [J]. BMJ-BRITISH MEDICAL JOURNAL, 2004, 329 (7470): : 821 - 824C
  • [6] Which diagnostic tests are most useful in a chest pain unit protocol?
    Goodacre S.
    Locker T.
    Arnold J.
    Angelini K.
    Morris F.
    [J]. BMC Emergency Medicine, 5 (1)
  • [7] Harbord R, 2008, METANDI: stata module to perform meta-analysis of diagnostic accuracy
  • [8] D-dimer testing for deep venous thrombosis: A metaanalysis
    Heim, SW
    Schectman, JM
    Siadaty, MS
    Philbrick, JT
    [J]. CLINICAL CHEMISTRY, 2004, 50 (07) : 1136 - 1147
  • [9] Direction and impact of language bias in meta-analyses of controlled trials:: empirical study
    Jüni, P
    Holenstein, F
    Sterne, J
    Bartlett, C
    Egger, M
    [J]. INTERNATIONAL JOURNAL OF EPIDEMIOLOGY, 2002, 31 (01) : 115 - 123
  • [10] Can causes of false-normal D-dimer test [SimpliREDS®] results be identified?
    Kraaijenhagen, RA
    Wallis, J
    Koopman, MMW
    de Groot, MR
    Piovella, F
    Prandoni, P
    Büller, HR
    [J]. THROMBOSIS RESEARCH, 2003, 111 (03) : 155 - 158