Valgus position of the femoral component causes abnormal kinematics in the presence of medial looseness in total knee arthroplasty: a computer simulation model of TKA for valgus knee osteoarthritis

被引:10
作者
Nishitani, Kohei [1 ]
Kuriyama, Shinichi [1 ]
Nakamura, Shinichiro [1 ]
Morita, Yugo [1 ]
Ito, Hiromu [1 ]
Matsuda, Shuichi [1 ]
机构
[1] Kyoto Univ, Grad Sch Med, Dept Orthopaed Surg, 54 Shogoin Kawahara Cho, Kyoto 6068507, Japan
关键词
Total knee arthroplasty; Total knee replacement; TKA; TKR; Valgus knee; Osteoarthritis; Computer simulation; Medial collateral ligament; Implant malposition; SINGLE-RADIUS; IN-VIVO; FLEXION GAP; CONTACT; REPLACEMENT; DEFORMITY; LAXITY;
D O I
10.1007/s00167-018-5264-0
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
PurposeTotal knee arthroplasty (TKA) for valgus knee osteoarthritis is challenging. Although overcorrection in TKA for valgus knee osteoarthritis is recommended, supportive data based on biomechanics have rarely been reported. The purpose of this study was to elucidate whether coronal rotation of the femoral compartment causes abnormal kinematics with or without medial looseness.MethodsMulti- and single-radius posterior-stabilised TKA implants were utilised in a computer simulation. A total of 4mm of slack were provided in the medial collateral ligament (MCL) with varus or valgus position of the femoral component to simulate the context of valgus knee osteoarthritis. Kinematics during gait and squatting activities were evaluated in each condition.ResultsDuring squatting, medial looseness and valgus replacement caused anterior translation of the medial femoral component in mid-flexion in the multi-radius implant. In the worst condition (7 degrees valgus replacement with MCL looseness), there was rapid anterior translation in the multi-radius implant, and moderate anterior translation in the single-radius implant. Although medial looseness alone did not cause abnormal kinematics during gait, the worst condition exhibited an anterior translation to 4.9mm in the multi-radius implant. This worst condition also exhibited a marked lift-off of 8.0 and 2.9mm in the multi- and single-radius implants, respectively. Varus position caused little abnormal kinematics even with MCL looseness.ConclusionValgus, not varus position of the femoral component caused abnormal kinematics with MCL looseness. To avoid valgus position, the safety target angle of femoral component would be slight varus rather than neutral in valgus knee OA.
引用
收藏
页码:2051 / 2060
页数:10
相关论文
共 24 条
  • [21] "Grand-piano sign" as a femoral rotational indicator in both varus and valgus knees: a simulation study of anterior resection surface in total knee arthroplasty
    Kokubu, Yasuhiko
    Kawahara, Shinya
    Hamai, Satoshi
    Akasaki, Yukio
    Tsushima, Hidetoshi
    Miyachika, Shinji
    Nakashima, Yasuharu
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2023, 31 (08) : 3259 - 3267
  • [22] “Grand-piano sign” as a femoral rotational indicator in both varus and valgus knees: a simulation study of anterior resection surface in total knee arthroplasty
    Yasuhiko Kokubu
    Shinya Kawahara
    Satoshi Hamai
    Yukio Akasaki
    Hidetoshi Tsushima
    Shinji Miyachika
    Yasuharu Nakashima
    Knee Surgery, Sports Traumatology, Arthroscopy, 2023, 31 : 3259 - 3267
  • [23] Total knee arthroplasty in patients with Ranawat type-II valgus arthritic knee with a marked coronal femoral bowing deformity: comparison between computer-assisted surgery and intra-articular resection
    Tsan-Wen Huang
    Po-Yao Chuang
    Chien-Yin Lee
    Shih-Jie Lin
    Kuo-Chin Huang
    Shih-Hsun Shen
    Yao-Hung Tsai
    Mel S. Lee
    Robert Wen-Wei Hsu
    Journal of Orthopaedic Surgery and Research, 11
  • [24] Femoral Component Malrotation Produces Quadriceps Weakness and Impaired Ambulatory Function following Total Knee Arthroplasty: Results of a Forward-Dynamic Computer Model
    Nettrour, John F.
    Razu, Swithin S.
    Keeney, James A.
    Guess, Trent M.
    JOURNAL OF KNEE SURGERY, 2020, 33 (11) : 1121 - 1127