Valgus position of the femoral component causes abnormal kinematics in the presence of medial looseness in total knee arthroplasty: a computer simulation model of TKA for valgus knee osteoarthritis

被引:10
|
作者
Nishitani, Kohei [1 ]
Kuriyama, Shinichi [1 ]
Nakamura, Shinichiro [1 ]
Morita, Yugo [1 ]
Ito, Hiromu [1 ]
Matsuda, Shuichi [1 ]
机构
[1] Kyoto Univ, Grad Sch Med, Dept Orthopaed Surg, 54 Shogoin Kawahara Cho, Kyoto 6068507, Japan
关键词
Total knee arthroplasty; Total knee replacement; TKA; TKR; Valgus knee; Osteoarthritis; Computer simulation; Medial collateral ligament; Implant malposition; SINGLE-RADIUS; IN-VIVO; FLEXION GAP; CONTACT; REPLACEMENT; DEFORMITY; LAXITY;
D O I
10.1007/s00167-018-5264-0
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
PurposeTotal knee arthroplasty (TKA) for valgus knee osteoarthritis is challenging. Although overcorrection in TKA for valgus knee osteoarthritis is recommended, supportive data based on biomechanics have rarely been reported. The purpose of this study was to elucidate whether coronal rotation of the femoral compartment causes abnormal kinematics with or without medial looseness.MethodsMulti- and single-radius posterior-stabilised TKA implants were utilised in a computer simulation. A total of 4mm of slack were provided in the medial collateral ligament (MCL) with varus or valgus position of the femoral component to simulate the context of valgus knee osteoarthritis. Kinematics during gait and squatting activities were evaluated in each condition.ResultsDuring squatting, medial looseness and valgus replacement caused anterior translation of the medial femoral component in mid-flexion in the multi-radius implant. In the worst condition (7 degrees valgus replacement with MCL looseness), there was rapid anterior translation in the multi-radius implant, and moderate anterior translation in the single-radius implant. Although medial looseness alone did not cause abnormal kinematics during gait, the worst condition exhibited an anterior translation to 4.9mm in the multi-radius implant. This worst condition also exhibited a marked lift-off of 8.0 and 2.9mm in the multi- and single-radius implants, respectively. Varus position caused little abnormal kinematics even with MCL looseness.ConclusionValgus, not varus position of the femoral component caused abnormal kinematics with MCL looseness. To avoid valgus position, the safety target angle of femoral component would be slight varus rather than neutral in valgus knee OA.
引用
收藏
页码:2051 / 2060
页数:10
相关论文
共 24 条
  • [1] Valgus position of the femoral component causes abnormal kinematics in the presence of medial looseness in total knee arthroplasty: a computer simulation model of TKA for valgus knee osteoarthritis
    Kohei Nishitani
    Shinichi Kuriyama
    Shinichiro Nakamura
    Yugo Morita
    Hiromu Ito
    Shuichi Matsuda
    Knee Surgery, Sports Traumatology, Arthroscopy, 2019, 27 : 2051 - 2060
  • [2] Is medial pivot total knee arthroplasty suitable for patients with valgus knee osteoarthritis?
    Iwakiri, Kentaro
    Ohta, Yoichi
    Ohyama, Yohei
    Minoda, Yukihide
    Kobayashi, Akio
    Nakamura, Hiroaki
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2022, 32 (03) : 551 - 557
  • [3] Is medial pivot total knee arthroplasty suitable for patients with valgus knee osteoarthritis?
    Kentaro Iwakiri
    Yoichi Ohta
    Yohei Ohyama
    Yukihide Minoda
    Akio Kobayashi
    Hiroaki Nakamura
    European Journal of Orthopaedic Surgery & Traumatology, 2022, 32 : 551 - 557
  • [4] Navigation-Assisted Total Knee Arthroplasty for a Valgus Knee Improves Limb and Femoral Component Alignment
    Lee, Sung-Sahn
    Kwon, Kyeu-Back
    Lee, Yong-In
    Moon, Young-Wan
    ORTHOPEDICS, 2019, 42 (02) : E253 - E259
  • [5] Excessive flexed position of the femoral component causes abnormal kinematics and joint contact/ligament forces in total knee arthroplasty
    Nishitani, Kohei
    Kuriyama, Shinichi
    Nakamura, Shinichiro
    Song, Young Dong
    Morita, Yugo
    Ito, Hiromu
    Matsuda, Shuichi
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [6] Intraoperative femoral rotational kinematics are similar in varus and valgus knees during medial pivot total knee arthroplasty
    Yamagami, Ryota
    Inui, Hiroshi
    Taketomi, Shuji
    Kono, Kenichi
    Kawaguchi, Kohei
    Sameshima, Shin
    Kage, Tomofumi
    Arakawa, Takahiro
    Tanaka, Sakae
    CLINICAL BIOMECHANICS, 2023, 101
  • [7] Partial restoration of knee kinematics in severe valgus deformity using the medial-pivot total knee arthroplasty
    Atsushi Kitagawa
    Kazunari Ishida
    Takaaki Chin
    Nobuhiro Tsumura
    Tetsushiro Iguchi
    Knee Surgery, Sports Traumatology, Arthroscopy, 2014, 22 : 1599 - 1606
  • [8] Partial restoration of knee kinematics in severe valgus deformity using the medial-pivot total knee arthroplasty
    Kitagawa, Atsushi
    Ishida, Kazunari
    Chin, Takaaki
    Tsumura, Nobuhiro
    Iguchi, Tetsushiro
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2014, 22 (07) : 1599 - 1606
  • [9] Total knee arthroplasty using trochlear groove as guide for position of femoral component in severe knee osteoarthritis
    Huang, Gangyong
    Xia, Jun
    Wang, Siqun
    Wei, Yibing
    Wu, Jianguo
    Chen, Feiyan
    Chen, Jie
    Shi, Jingsheng
    BMC SURGERY, 2016, 16
  • [10] The lateral approach for total knee arthroplasty in valgus osteoarthritis provides similar clinical and radiological results compared with the medial approach
    Alsalloum, Maamoun
    Alimy, Assil-Ramin
    Hubert, Jan
    Rolvien, Tim
    Fink, Bernd
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2025, 33 (04) : 1378 - 1386