3 T contrast-enhanced magnetic resonance angiography for evaluation of the intracranial arteries - Comparison with time-of-flight magnetic resonance angiography and multislice computed tomography angiography

被引:53
|
作者
Villablanca, J. Pablo
Nael, Kambiz
Habibi, Reza
Nael, Ali
Laub, Gerhard
Finn, J. Paul
机构
[1] Univ Calif Los Angeles, David Geffen Sch Med, Dept Radiol Sci, Los Angeles, CA 90095 USA
[2] Siemens Med Solut, Los Angeles, CA USA
关键词
MR angiography; intracranial arteries; CT angiography; high magnetic field or 3 T; parallel acquisition;
D O I
10.1097/01.rli.0000242835.00032.f5
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: We sought to prospectively evaluate the image quality and visualization of the intracranial arteries using high spatial resolution contrast-enhanced magnetic resonance angiography (CE-MRA) at 3 T and to perform intraindividual comparison with time-of-flight (TOF) MRA and multislice CT angiography (CTA). Materials and Methods: Twelve patients (5 men, 7 women, 37-71 years of age) with suspected cerebrovascular disease prospectively underwent MRA and CTA. MRA was performed on a 3 T MR system, including both 3-dimensional (3D) TOF (Voxel dimension: 0.6 X 0.5 X 0.9 mm(3) in 5 minutes and 40 seconds) and 3D CE-MRA (voxel dimension: 0.7 X 0.7 X 0.8 mm(3) in 20 seconds, using parallel acquisition with an acceleration factor of 4). CTA images were acquired on a 16-slice CT scanner (voxel dimension: 0.35 X 0.35 X 0.8 mm(3) in 17 seconds). The image quality and visualization of up to 26 intracranial arterial segments in each study was evaluated by 2 experienced radiologists. The arterial diameter for selective intracranial arteries was measured independently on each of the 3 studies, and statistical analysis and comparative correlation was performed. Results: A total of 312 arterial segments were examined by CE-MRA, TOF-MRA, and CTA. The majority of intracranial arteries (87%) were visualized with diagnostic image quality on CE-MRA with a significant correlation to TOF (R values = 0.84; 95% confidence interval 0.79-0.86, P < 0.0001), and to CTA (R values = 0.74; 95% confidence interavl 0.68-0.78, P < 0.001). The image quality for small intracranial arteries, including the anterior-inferior cerebellar artery, the posterior communicating artery, and the M3 branch of the middle cerebral artery, was significantly lower on CE-MRA compared with TOF and CTA (P < 0.03). There was a significant correlation for the dimensional measurements of arterial diameters at CE-MRA with TOF (r = 0.88, 95% confidence interval 0.81-0.93), and CTA (r = 0.83, 95% confidence interval 0.73-0.90). Conclusion: The described 3 T CE-MRA protocol, spanning from the cervical to the intracranial vessels, visualized and characterized the majority of intracranial arteries with image quality comparable with that obtained using TOF-MRA and CTA. Further clinical studies are required to establish the accuracy of the technique in a broader clinical setting.
引用
收藏
页码:799 / 805
页数:7
相关论文
共 50 条
  • [1] Contrast-enhanced Magnetic Resonance Angiography in Stroke Diagnostics Additional Information Compared with Time-of-Flight Magnetic Resonance Angiography?
    Alfke, K.
    Jensen, U.
    Pool, C.
    Rohr, A.
    Bruening, R.
    Weber, J.
    Bartsch, T.
    Stingele, R.
    Jansen, O.
    CLINICAL NEURORADIOLOGY, 2011, 21 (01) : 5 - 10
  • [2] Contrast-enhanced magnetic resonance angiography carotid arteries
    U-King-Im, J
    Trivedi, R
    Gillard, JH
    STROKE, 2003, 34 (05) : E15 - E15
  • [3] Contrast-enhanced MR angiography at 3T in the evaluation of intracranial aneurysms: A comparison with time-of-flight MR angiography
    Nael, K.
    Villablanca, J. P.
    Saleh, R.
    Pope, W.
    Nael, A.
    Laub, G.
    Finn, J. P.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2006, 27 (10) : 2118 - 2121
  • [4] Visualisation of lenticulostriate arteries using contrast-enhanced time-of-flight magnetic resonance angiography at 7 Tesla
    Osuafor, Christopher N.
    Rua, Catarina
    Mackinnon, Andrew D.
    Egle, Marco
    Benjamin, Philip
    Tozer, Daniel J.
    Rodgers, Christopher T.
    Markus, Hugh S.
    SCIENTIFIC REPORTS, 2022, 12 (01):
  • [5] Visualisation of lenticulostriate arteries using contrast-enhanced time-of-flight magnetic resonance angiography at 7 Tesla
    Christopher N. Osuafor
    Catarina Rua
    Andrew D. Mackinnon
    Marco Egle
    Philip Benjamin
    Daniel J. Tozer
    Christopher T. Rodgers
    Hugh S. Markus
    Scientific Reports, 12 (1)
  • [6] Vessel contrast at three Tesla in time-of-flight magnetic resonance angiography of the intracranial and carotid arteries
    Al-Kwifi, O
    Emery, DJ
    Wilman, AH
    MAGNETIC RESONANCE IMAGING, 2002, 20 (02) : 181 - 187
  • [7] Follow-up of coiled cerebral aneurysms: Comparison of three-dimensional time-of-flight magnetic resonance angiography at 3 tesla with three-dimensional time-of-flight magnetic resonance angiography and contrast-enhanced magnetic resonance angiography at 1.5 tesla
    Anzalone, Nicoletta
    Scomazzoni, Francesco
    Cirillo, Mario
    Cadioli, Marcello
    Iadanza, Antonella
    Kirchin, Miles A.
    Scotti, Giuseppe
    INVESTIGATIVE RADIOLOGY, 2008, 43 (08) : 559 - 567
  • [8] Contrast-Enhanced Magnetic Resonance Angiography
    Chandra, Tushar
    Pukenas, Bryan
    Mohan, Suyash
    Melhem, Elias
    MAGNETIC RESONANCE IMAGING CLINICS OF NORTH AMERICA, 2012, 20 (04) : 687 - +
  • [9] Contrast-Enhanced Magnetic Resonance Angiography
    Vasile, Julie V.
    Newman, Tiffany M.
    Prince, Martin R.
    Rusch, David G.
    Greenspun, David T.
    Allen, Robert J.
    Levine, Joshua L.
    CLINICS IN PLASTIC SURGERY, 2011, 38 (02) : 263 - +
  • [10] Contrast-enhanced magnetic resonance angiography
    Roditi, G
    BRITISH JOURNAL OF SURGERY, 2002, 89 (07) : 817 - 820