Determination of alkylphenols in water samples using liquid chromatography-tandem mass spectrometry after pre-column derivatization with dansyl chloride

被引:38
作者
Pernica, Marek [1 ]
Poloucka, Petra [1 ]
Seifertova, Marta [1 ]
Simek, Zdenek [1 ]
机构
[1] Masaryk Univ, Fac Sci, Res Ctr Tox Cpds Environm RECETOX, Brno 62500, Czech Republic
关键词
Alkylphenols; Liquid chromatography; Electrospray ionization; Tandem mass spectrometry; Chemical derivatization of alkylphenols; SOLID-PHASE EXTRACTION; BISPHENOL-A; GAS-CHROMATOGRAPHY; PHENOLIC-COMPOUNDS; WASTE-WATER; 4-TERT-OCTYLPHENOL; QUANTIFICATION; QUANTITATION; INJECTION; ALCOHOLS;
D O I
10.1016/j.chroma.2015.09.030
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The present study describes an effect of reaction condition of pre-column derivatization of alkylphenols (APs): bisphenol A (BPA), 4-tert-octylphenol (4-t-OP), 4-octylphenol (4-OP), 4-n-nonylphenol (4-n-NP), and isomers of 4-nonylphenol (iso-NP) with 5-(dimethylamino) naphthalene-l-sulfonyl chloride (dansyl chloride, DNSC) on their LC-ESI-MS/MS determination in water samples. Chemical derivatization improves the sensitivity and selectivity of LC-MS/MS analysis. In principle, alkylphenols can be analyzed by LC-MS/MS without derivatization. However, pre-column derivatization of APs increases the sensitivity up to 1000 times in comparison with the analysis of underivatized alkylphenols. Reaction conditions affecting formation of the DNSC-derivatives, such as various solvent, reaction temperature, reaction time, DNSC concentration and pH values were tested. The most suitable conditions, in terms of achieving a high sensitivity, resulting from this study are: acetonitrile as reaction solvent, 60 min as reaction time, 60 degrees C as reaction temperature, pH values 10.5, 0.5 mg mL(-1) as DNSC concentration. Calibration curves are linear at least in the range of 1-1000 ng mL(-1), limits of detection (LOD) and limits of quantification (LOQ) ranging from 0.02 to 0.25 pg/injection and from 0.08 to 0.83 pg/injection, respectively. The improved procedure was successfully applied for the analysis of APs and BPA in real water samples. The median concentration of BPA and iso-NP obtained in bottled waters was 4.7 ng L-1 and 33.5 ng L-1, respectively. The median concentration of 4-t-OP was 1.3 ng L-1. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:49 / 56
页数:8
相关论文
共 31 条
[1]  
[Anonymous], 2006, The EFSA Journal, V428, P1, DOI DOI 10.2903/J.EFSA.2006.69R
[2]  
[Anonymous], INT RISK INF SYST
[3]  
[Anonymous], 815R09011 EPA
[4]   Solid phase analytical derivatization as a sample preparation method [J].
Atapattu, Sanka N. ;
Rosenfeld, Jack M. .
JOURNAL OF CHROMATOGRAPHY A, 2013, 1296 :204-213
[5]   Determination of alkylphenols and alkylphenol carboxylates in wastewater and river samples by hemimicelle-based extraction and liquid chromatography-ion trap mass spectrometry [J].
Cantero, Manuel ;
Rubio, Soledad ;
Perez-Bendito, Dolores .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1120 (1-2) :260-267
[6]   Alkylphenols and phthalates in bottled waters [J].
Diana, Amiridou ;
Dimitra, Voutsa .
JOURNAL OF HAZARDOUS MATERIALS, 2011, 185 (01) :281-286
[7]   Determination of 4-nonylphenol in water samples using 4-(2,6-dimethylhept-3-yl)phenol as new internal standard [J].
Fischer, Axel R. ;
Lan, Nham Thi Phuong ;
Wiedemann, Cornelia ;
Heide, Petra ;
Werner, Peter ;
Schmidt, Arndt W. ;
Theumer, Gabriele ;
Knoelker, Hans-Joachim .
JOURNAL OF CHROMATOGRAPHY A, 2010, 1217 (17) :2950-2955
[8]   Isolation, purification and determination of 4-n-nonylphenol and 4-tert-octylphenol in aqueous and biological samples [J].
Gadzala-Kopciuch, Renata ;
Filipiak, Anna ;
Buszewski, Boguslaw .
TALANTA, 2008, 74 (04) :655-660
[9]   Determination of alkyl, chloro and mononitrophenols in water by sample-acetylation and automatic on-line solid phase extraction gas chromatography mass spectrometry [J].
Jahr, D .
CHROMATOGRAPHIA, 1998, 47 (1-2) :49-56
[10]   Determination of endocrine-disrupting compounds in environmental samples using gas and liquid chromatography with mass spectrometry [J].
Jeannot, R ;
Sabik, H ;
Sauvard, E ;
Dagnac, T ;
Dohrendorf, K .
JOURNAL OF CHROMATOGRAPHY A, 2002, 974 (1-2) :143-159