Latest Advances in the Treatment of Bicuspid Aortic Valve

被引:0
作者
Della Corte, Alessandro [1 ,2 ]
Lo Presti, Federica [2 ]
机构
[1] Univ Campania L Vanvitelli, Dept Translat Med Sci, Naples, Italy
[2] Casa Cura San Michele, Heart & Vessels Dept, Cardiac Surg Unit, Maddaloni, Italy
来源
SURGICAL TECHNOLOGY INTERNATIONAL-INTERNATIONAL DEVELOPMENTS IN SURGERY AND SURGICAL RESEARCH | 2020年 / 37卷
关键词
WALL SHEAR-STRESS; KNOWLEDGE GAPS; REPLACEMENT; TRANSCATHETER; AORTOPATHY; STENOSIS; DISEASE; ANNULOPLASTY; DURABILITY; OUTCOMES;
D O I
暂无
中图分类号
R61 [外科手术学];
学科分类号
摘要
Bicuspid aortic valve (BAV) is the most frequent congenital cardiac defect, and affects 0.5-2% of live births. Almost half of BAV subjects develop different degrees of valvular dysfunction during their lifetime. In both echocardiographic cohorts and surgical series, pure aortic regurgitation is significantly less common than stenosis. BAV also carries a higher risk of aortic aneurysm, aortic dissection or aortic valve endocarditis compared to the general population. Once aortic insufficiency reaches threshold criteria for surgical treatment, the valve has to be replaced (conventional aortic valve replacement, the outcomes of which are well established) or repaired. Repair techniques for regurgitant BAVs and valve-sparing surgery for BAV-related aneurysms have evolved remarkably over the past several decades. Improvements in our understanding of the mechanisms of normal and pathological BAV function and the development of criteria and techniques to address all the pathologic components of valve and root have supported better repair results. The more frequent stenotic BAV is treated by prosthetic valve replacement or, in recent years, by trans-catheter prosthetic replacement (TAVR), the application of which in the BAV setting is increasing, as with tricuspid aortic valve (TAV) stenosis, especially since indications are extended to medium-risk patients. It has been reported that the risk of paravalvular leak and/or prosthesis malposition is higher in BAV than in TAV stenosis, due to the more elliptical annulus and the calcified raphe of the bicuspid valve. New-generation balloon-expandable devices seem to be capable of lowering the rates of these complications. As research in this field keeps filling in the gaps in current knowledge about bicuspid malformation and its common complications, further advancements in their treatment are awaited.
引用
收藏
页数:6
相关论文
共 69 条
[1]   Valve Configuration Determines Long-Term Results After Repair of the Bicuspid Aortic Valve [J].
Aicher, Diana ;
Kunihara, Takashi ;
Abou Issa, Omar ;
Brittner, Brigitte ;
Graeber, Stefan ;
Schaefers, Hans-Joachim .
CIRCULATION, 2011, 123 (02) :178-185
[2]   Aortic valve repair leads to a low incidence of valve-related complications [J].
Aicher, Diana ;
Fries, Roland ;
Rodionycheva, Svetlana ;
Schmidt, Kathrin ;
Langer, Frank ;
Schaefers, Hans-Joachim .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2010, 37 (01) :127-132
[3]   Comparison of Outcomes and Presentation in Men-Versus-Women With Bicuspid Aortic Valves Undergoing Aortic Valve Replacement [J].
Andrei, Adin-Cristian ;
Yadlapati, Ajay ;
Malaisrie, S. Chris ;
Puthumana, Jyothy J. ;
Li, Zhi ;
Rigolin, Vera H. ;
Mendelson, Marla ;
Clennon, Colleen ;
Kruse, Jane ;
Fedak, Paul W. M. ;
Thomas, James D. ;
Higgins, Jennifer A. ;
Rinewalt, Daniel ;
Bonow, Robert O. ;
McCarthy, Patrick M. .
AMERICAN JOURNAL OF CARDIOLOGY, 2015, 116 (02) :250-255
[4]   Bicuspid Aortic Valve Is Associated With Altered Wall Shear Stress in the Ascending Aorta [J].
Barker, Alex J. ;
Markl, Michael ;
Buerk, Jonas ;
Lorenz, Ramona ;
Bock, Jelena ;
Bauer, Simon ;
Schulz-Menger, Jeanette ;
von Knobelsdorff-Brenkenhoff, Florian .
CIRCULATION-CARDIOVASCULAR IMAGING, 2012, 5 (04) :457-466
[5]  
Baumgartner H, 2018, EUR HEART J, V39, P1980, DOI [10.1093/eurheartj/ehx636, 10.1093/eurheartj/ehx391]
[6]   Aortic Dilation in Bicuspid Aortic Valve Disease Flow Pattern Is a Major Contributor and Differs With Valve Fusion Type [J].
Bissell, Malenka M. ;
Hess, Aaron T. ;
Biasiolli, Luca ;
Glaze, Steffan J. ;
Loudon, Margaret ;
Pitcher, Alex ;
Davis, Anne ;
Prendergast, Bernard ;
Markl, Michael ;
Barker, Alex J. ;
Neubauer, Stefan ;
Myerson, Saul G. .
CIRCULATION-CARDIOVASCULAR IMAGING, 2013, 6 (04) :499-507
[7]   Impact of valve prosthesis-patient mismatch on short-term mortality after aortic valve replacement [J].
Blais, C ;
Dumesnil, JG ;
Baillot, R ;
Simard, S ;
Doyle, D ;
Pibarot, P .
CIRCULATION, 2003, 108 (08) :983-988
[8]   Outcomes of transcatheter aortic valve replacement in bicuspid aortic valve stenosis [J].
Bob-Manuel, Tamunoinemi ;
Heckle, Mark R. ;
Ifedili, Ikechukwu A. ;
Wang, Jiajing ;
Ibebuogu, Uzoma N. .
ANNALS OF TRANSLATIONAL MEDICINE, 2019, 7 (05)
[9]   The American Association for Thoracic Surgery consensus guidelines on bicuspid aortic valve-related aortopathy: Full online-only version [J].
Borger, Michael A. ;
Fedak, Paul W. M. ;
Stephens, Elizabeth H. ;
Gleason, Thomas G. ;
Girdauskas, Evaldas ;
Ikonomidis, John S. ;
Khoynezhad, Ali ;
Siu, Samuel C. ;
Verma, Subodh ;
Hope, Michael D. ;
Cameron, Duke E. ;
Hammer, Donald F. ;
Coselli, Joseph S. ;
Moon, Marc R. ;
Sundt, Thoralf M. ;
Barker, Alex J. ;
Markl, Michael ;
Della Corte, Alessandro ;
Michelena, Hector I. ;
Elefteriades, John A. .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2018, 156 (02) :E41-E74
[10]   Feature Tracking Cardiac MRI Reveals Abnormalities in Ventricular Function in Patients With Bicuspid Aortic Valve and Preserved Ejection Fraction [J].
Burris, Nicholas S. ;
Lima, Ana Paula S. ;
Hope, Michael D. ;
Ordovas, Karen G. .
TOMOGRAPHY, 2018, 4 (01) :26-32