Clinical utility of ultrasound to prospectively monitor distraction of magnetically controlled growing rods

被引:35
作者
Cheung, Jason PuiYin [1 ]
Bow, Cora [1 ]
Samartzis, Dino [1 ]
Ganal-Antonio, Anne Kathleen B. [2 ]
Cheung, Kenneth Man Chee [1 ]
机构
[1] Univ Hong Kong, Queen Mary Hosp, Dept Orthopaed & Traumatol, Pokfulam Rd, Hong Kong, Hong Kong, Peoples R China
[2] Makati Med Ctr, Dept Orthoped, Makati, Philippines
关键词
Controlled; Correlation; Distraction; Growing; Magnetically; Rod; Ultrasound; EARLY-ONSET SCOLIOSIS; IONIZING-RADIATION EXPOSURE; CANCER-MORTALITY; SURGERY; COMPLICATIONS; DEFORMITIES; AGREEMENT; SPINE;
D O I
10.1016/j.spinee.2015.10.044
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND CONTEXT: Growing rods are commonly used for surgical treatment of skeletally immature patients with scoliosis, but require repeated surgeries for distractions and are fraught with complications. As an alternative, the use of magnetically controlled growing rods (MCGR) allows for more frequent non-invasive distractions to mimic normal growth. However, more plain radiographs are needed to monitor increased distraction frequency, thereby increasing ionizing radiation exposure to the developing child. The use of ultrasound, which emits no radiation, has been found in a cross-sectional study to be reliable in measuring MCGR distractions. PURPOSE: The study aims to address the prospective clinical utility of ultrasound compared with plain radiographs for assessing MCGR distractions. STUDY DESIGN: This is a prospective study. PATIENT SAMPLE: The study includes patients with early-onset scoliosis undergoing distractions after MCGR implant. OUTCOME MEASURES: The distraction length on plain radiographs and ultrasound was measured. METHODS: This is a prospective study of patients treated with MCGR. Patients with both single- and dual-rod systems were included. Outpatient distractions were performed at monthly intervals, targeting 2 mm of distraction on each occasion. Assessment of distraction length was monitored by ultrasound at each visit; plain radiographs were taken every 6 months and were compared with ultrasound measurements. RESULTS: Nine patients (5 female, 4 male), with a mean of 29 distractions (standard deviation [SD] +/- 14.3), were recruited. The mean distracted length per 6 months was 5.7 mm (SD +/- 3.6 mm) on plain radiographs and 5.2 mm (SD +/- 3.9 mm) on ultrasound for the concave rod, and 6.1 mm (SD +/- 3.6 mm) on plain radiographs and 5.9 mm (SD +/- 3.8 mm) on ultrasound for the convex rod. Excellent inter-and intra-rater reliabilities were observed for radiographic and ultrasound measurements. An excellent correlation was noted between the two imaging modalities (r=0.93; p<.0001). CONCLUSIONS: This is the first prospective study to validate that ultrasound assessment of MCGR distraction lengths was highly comparable with that of plain radiographs. The present study has verified that ultrasound can be used to document length changes by distraction over time and that it had high clinical utility. Ultrasound can be a reliable alternative to plain radiographs, thereby avoiding radiation exposure and its potential detrimental sequelae in the developing child. (C) 2015 The Authors. Published by Elsevier Inc.
引用
收藏
页码:204 / 209
页数:6
相关论文
共 34 条
[31]   Comparison of single and dual growing rod techniques followed through definitive surgery - A preliminary study [J].
Thompson, GH ;
Akbarnia, BA ;
Kostial, P ;
Poe-Kochert, C ;
Armstrong, DG ;
Roh, J ;
Lowe, R ;
Asher, MA ;
Marks, DS .
SPINE, 2005, 30 (18) :2039-2044
[32]   Applying concepts of generalizability theory on clinical trial data to investigate sources of variation and their impact on reliability [J].
Vangeneugden, T ;
Laenen, A ;
Geys, H ;
Renard, D ;
Molenberghs, G .
BIOMETRICS, 2005, 61 (01) :295-304
[33]  
Wick Jane M, 2012, AORN J, V96, P163, DOI 10.1016/j.aorn.2012.05.008
[34]   POSTERIOR SPINAL ARTHRODESIS FOR CONGENITAL SCOLIOSIS - AN ANALYSIS OF THE CASES OF 290 PATIENTS, 5 TO 19 YEARS OLD [J].
WINTER, RB ;
MOE, JH ;
LONSTEIN, JE .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1984, 66A (08) :1188-1197