摘要
New software methods that incorporate iterative reconstruction, resolution recovery, and noise compensation now provide the ability to maintain or improve myocardial perfusion SPECT image quality with conventional sodium iodide cameras. Despite lower image counting statistics associated with significantly decreased injected radiopharmaceutical doses or shortened acquisition times or both, image quality is preserved or even improved compared with conventional processing methods. The ability to prescribe a desired myocardial count density by preselecting a SPECT acquisition time now avoids additional patient radiation exposure associated with "weight-based" dosing. More recent advancements, including temporal correlation among the gated perfusion frames and higher resolution SPECT acquisitions, hold promise to further improve image quality and diagnostic accuracy. Phase analysis of gated perfusion SPECT provides the ability to assess cardiac dyssynchrony and to select those patients who will most benefit from resynchronization therapy. In combination with the higher counting statistics afforded by the new solid-state dedicated cardiac cameras, these software advancements allow for even further decreased patient radiation doses or acquisition times or both. List-mode software allows for refinement of myocardial perfusion SPECT by interrogating particular data from selected cardiac cycles. Rejection of frames degraded by arrhythmic cardiac cycles or excessive extracardiac uptake can be excluded for reconstruction. Respiratory gating, which diminishes cardiac motion and potentially decreases diaphragmatic attenuation, has been demonstrated to improve diagnostic specificity. With high-count first-pass list-mode acquisitions at rest and during pharmacologic vasodilatation, it may be possible to measure global and regional myocardial perfusion reserve to more accurately diagnose coronary artery disease and avoid false-negative studies owing to balanced ischemia. Semin Nucl Med 44:252-273 (C) 2014 Elsevier Inc. All rights reserved.
引用
收藏
页码:252 / 273
页数:22
相关论文
共 63 条
[1]   Bayesian image reconstruction for emission tomography based on median root prior [J].
Alenius, S ;
Ruotsalainen, U .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1997, 24 (03) :258-265
[2]   Semiqualitative Visual and Quantitative Morphometric Evaluations of Reduced Scan Time and Wide-Beam Reconstruction in Rest-Gated Stress SPECT Myocardial Perfusion Imaging [J].
Basso, Danny ;
Passmore, Gregory ;
Holman, Michael ;
Rogers, Ward ;
Walters, Leslie ;
Zecchin, Thomas ;
Butler, Jayme .
JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY, 2009, 37 (04) :233-239
[3]   Multicenter investigation comparing a highly efficient half-time stress-only attenuation correction approach against standard rest-stress Tc-99m SPECT imaging [J].
Bateman, Timothy M. ;
Heller, Gary V. ;
McGhie, A. Iain ;
Courter, Staci A. ;
Golub, Robert A. ;
Case, James A. ;
Cullom, S. James .
JOURNAL OF NUCLEAR CARDIOLOGY, 2009, 16 (05) :726-735
[4]  
Ben-Haim S, 2006, IEEE NUCL SCI S, P2285
[5]   A fast cardiac gamma camera with dynamic SPECT capabilities: design, system validation and future potential [J].
Bocher, Moshe ;
Blevis, Ira M. ;
Tsukerman, Leonid ;
Shrem, Yigal ;
Kovalski, Gil ;
Volokh, Lana .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2010, 37 (10) :1887-1902
[6]  
Bogdanich W, 2010, NY TIMES, pB7
[7]   Clinical results of a novel wide beam reconstruction method for shortening scan time of Tc-99m cardiac SPECT perfusion studies [J].
Borges-Neto, Salvador ;
Pagnanelli, Robert A. ;
Shaw, Linda K. ;
Honeycutt, Emily ;
Shwartz, Shuli C. ;
Adams, George L. ;
Coleman, Ralph Edward .
JOURNAL OF NUCLEAR CARDIOLOGY, 2007, 14 (04) :555-565
[8]  
Bruyant PP, 2002, J NUCL MED, V43, P1343
[9]   Real-time breath-hold triggering of myocardial perfusion imaging with a novel cadmium-zinc-telluride detector gamma camera [J].
Buechel, Ronny R. ;
Pazhenkottil, Aju P. ;
Herzog, Bernhard A. ;
Husmann, Lars ;
Nkoulou, Rene N. ;
Burger, Irene A. ;
Valenta, Ines ;
Wyss, Christophe A. ;
Ghadri, Jelena R. ;
Kaufmann, Philipp A. .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2010, 37 (10) :1903-1908
[10]   Ultrafast nuclear myocardial perfusion imaging on a new gamma camera with semiconductor detector technique: first clinical validation [J].
Buechel, Ronny R. ;
Herzog, Bernhard A. ;
Husmann, Lars ;
Burger, Irene A. ;
Pazhenkottil, Aju P. ;
Treyer, Valerie ;
Valenta, Ines ;
von Schulthess, Patrick ;
Nkoulou, Rene ;
Wyss, Christophe A. ;
Kaufmann, Philipp A. .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2010, 37 (04) :773-778