Assessment of the indoor air quality in copy centres at Aveiro, Portugal

被引:26
|
作者
Vicente, Estela D. [1 ]
Ribeiro, Joao P. [1 ]
Custodio, Danilo [1 ]
Alves, Celia A. [1 ]
机构
[1] Univ Aveiro, Dept Environm & Planning, Ctr Environm & Marine Studies, P-3810193 Aveiro, Portugal
关键词
Indoor air quality; Copy centre; Particulate matter; Ozone; VOLATILE ORGANIC-COMPOUNDS; VENTILATION RATES; OFFICE EQUIPMENT; OZONE; HEALTH; EXPOSURE; POLLUTANTS; PERFORMANCE; BUILDINGS; CONTAMINANTS;
D O I
10.1007/s11869-016-0401-8
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This study presents continuous measurements of size-segregated particulate matter, total volatile organic compounds, ozone, formaldehyde, comfort parameters (temperature and relative humidity), CO and CO2 at two copy centres (A and B) in Aveiro, Portugal. PM10 samples collected with low-volume samplers were used to determine the carbonaceous content (organic and elemental carbon) by a thermo-optical technique. Mean PM10 levels of 55.8 +/- 7.50 mu g m(-3) and 51.3 +/- 9.35 mu g m(-3) were obtained in copy centres A and B, respectively. The 24-h indoor PM10 concentration at both copy centres exceeded the protection limit established by the Portuguese legislation. Around 60 % of the PM10 were composed of particles with sizes below 2.5 mu m. On average, organic carbon accounted for 27.6 % (copy centre A) and 18.6 % (copy centre B) of the PM10 mass indoors, whereas a lower mass fraction of 11.5 % was found for both outdoor spaces. The much higher indoor levels of organic carbon suggest significant contribution by indoor sources. The ozone level increased in both copy centres when the photocopiers started to work. Mean ozone levels (0.055 +/- 0.005 and 0.048 +/- 0.006 ppm in copy centres A and B, respectively) during business hours may exceed the standard recommended for workplaces (0.05 ppm), representing a cause of possible adverse health effects on employees. The indoor-to-outdoor ozone concentration ratios were greater than 1 in both centres, indicating an important contribution of indoor sources. Formaldehyde levels remained always below the World Health Organisation guideline for indoor air (0.1 mg m(-3)). Total concentrations of volatile organic compounds were also relatively low, in general ranging from around 190 to 300 ppb. The indoor-to-outdoor concentration ratios were in the range between 0.70 and 0.76. Results showed that operation of laser printers can lead to high particulate matter and ozone concentration indoors. Pollutants associated with printing equipment have potential to cause adverse health effects if exposures are sufficiently high. Precautions should be taken to minimise the risks of exposed workers.
引用
收藏
页码:117 / 127
页数:11
相关论文
共 50 条
  • [21] A review and comparison of the indoor air quality requirements in selected building standards and certifications
    Wei, Guanqiong
    Yu, Xiyang
    Fang, Lin
    Wang, Qingqin
    Tanaka, Toshio
    Amano, Kenji
    Yang, Xudong
    BUILDING AND ENVIRONMENT, 2022, 226
  • [22] Assessment of the air quality in 20 public indoor swimming pools located in the Northern Region of Portugal
    Gabriel, Marta F.
    Felgueiras, F.
    Mourao, Z.
    Fernandes, E. O.
    ENVIRONMENT INTERNATIONAL, 2019, 133
  • [23] Assessment of indoor air quality in air-conditioned small business units with no mechanical ventilation
    Sankaran, Gayatri
    Tan, Sze Tat
    Shen, Joanna
    Gutierrez, Ramona
    Ng, Lee Ching
    Sim, Shuzhen
    ATMOSPHERIC ENVIRONMENT, 2023, 299
  • [24] Risk Assessment of Indoor Air Quality and Its Association with Subjective Symptoms among Office Workers in Korea
    Jung, Dayoung
    Choe, Youngtae
    Shin, Jihun
    Kim, Eunche
    Min, Gihong
    Kim, Dongjun
    Cho, Mansu
    Lee, Chaekwan
    Choi, Kilyong
    Woo, Byung Lyul
    Yang, Wonho
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2022, 19 (04)
  • [25] Use of the IAQmeter in Indoor Air Quality Monitoring Studies
    Dumala, Slawomira
    Guz, Lukasz
    Badora, Anna
    Skwarczynski, Mariusz
    Gawel, Dariusz
    JOURNAL OF ECOLOGICAL ENGINEERING, 2024, 25 (12): : 287 - 297
  • [26] Consequences of energy renovation on indoor air quality in kindergartens
    Dovjak, Mateja
    Slobodnik, Jan
    Krainer, Ales
    BUILDING SIMULATION, 2020, 13 (03) : 691 - 708
  • [27] Hazard Evaluation of Indoor Air Quality in Bank Offices
    Saidin, Hamidi
    Razak, Azli Abd
    Mohamad, Mohd Faizal
    Ul-Saufie, Ahmad Zia
    Zaki, Sheikh Ahmad
    Othman, Nor'azizi
    BUILDINGS, 2023, 13 (03)
  • [28] INDOOR MATERIALS AND AIR QUALITY ASSESSMENT
    Senitkova, Ingrid
    GEOCONFERENCE ON NANO, BIO AND GREEN - TECHNOLOGIES FOR A SUSTAINABLE FUTURE, VOL II (SGEM 2014), 2014, : 207 - 212
  • [29] Towards an integrative approach of improving indoor air quality
    Bluyssen, Philomena M.
    BUILDING AND ENVIRONMENT, 2009, 44 (09) : 1980 - 1989
  • [30] Indoor air quality monitoring and source apportionment using low-cost sensors
    Higgins, Christina
    Kumar, Prashant
    Morawska, Lidia
    ENVIRONMENTAL RESEARCH COMMUNICATIONS, 2024, 6 (01):