A Computational Approach to the "Optimal" Screw Axis Location and Orientation in the Scaphoid Bone

被引:54
作者
Leventhal, Evan L.
Wolfe, Scott W.
Walsh, Eric F.
Crisco, Joseph J.
机构
[1] Brown Univ, Rhode Isl Hosp, Warren Alpert Med Sch, Dept Orthopaed,Bioengn Lab, Providence, RI 02903 USA
[2] Cornell Univ, Hosp Special Surg, Weill Med Coll, Hand & Upper Extrem Ctr, New York, NY 10021 USA
来源
JOURNAL OF HAND SURGERY-AMERICAN VOLUME | 2009年 / 34A卷 / 04期
关键词
Axis; computation; optimization; scaphoid; screw; PERCUTANEOUS INTERNAL-FIXATION; ASSISTED DORSAL APPROACH; CANNULATED SCREW; FRACTURES; KINEMATICS; PLACEMENT; REDUCTION; NONUNION; LUNATE; WRIST;
D O I
10.1016/j.jhsa.2009.01.011
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose The development of small cannulated screws permitted minimally invasive percutaneous fixation of acute scaphoid fractures. There are known mechanical advantages to increased screw length and central screw placement, as well as documented deleterious effects of screw malposition, including articular protrusion, proximal pole fracture, and non-union. The purpose of this study was to compare 2 methods of calculating a screw axis accessible via a volar surgical approach. Methods To prevent screw protrusion through the surface of the scaphoid, we required the central screw axis to be contained completely within a "safe zone," defined as a 3-dimensional region located a fixed distance from the inner cortical surface. Safe zones were calculated based on computed tomography-generated models of the right scaphoid from 10 healthy subjects. Two methods for screw axis calculation were compared: (1) maximum screw length (MSC) within the safe zone and (2) a cylinder best-fit (CYL) to the safe zone. The volar approach was defined as percutaneous screw placement through the scaphoid tubercle without violation of the trapezium. Resultant screw axes were compared between the 2 methods for volar accessibility, screw length, and location of the screw axis. Results The MSL axes were completely accessible without violating the trapezium in all but 2 subjects. The average MSL axes were 11% longer than the CYL axes and passed significantly closer to the scaphoid tubercle than did the CYL axes (1.8 mm vs 6.4 mm). The MSL axes passed significantly farther (1.6 mm) from the bone centroid than did the CYL axes, (0.4 mm). All 10 MSL axes were located in the central one-third of the proximal pole. Conclusions Without violation of the trapezium, MSL axis can be attained via the volar percutaneous approach to the scaphoid. Using this approach, the ideal starting point for maximal screw, length was located 1.7 mm dorsal and 0.2 mm radial to the apex of the scaphoid tubercle. (J Hand Surg 2009;34A:677-684. Copyright (c) 2009 by the American Society for Surgery of the Hand. All rights reserved.)
引用
收藏
页码:677 / 684
页数:8
相关论文
共 28 条
  • [1] TECHNICAL FACTORS RELATED TO HERBERT SCREW FIXATION
    ADAMS, BD
    BLAIR, WF
    REAGAN, DS
    GRUNDBERG, AB
    [J]. JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1988, 13A (06): : 893 - 899
  • [2] Percutaneous screw fixation or cast immobilization for nondisplaced scaphoid fractures
    Bond, CD
    Shin, AY
    McBride, MT
    Dao, KD
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2001, 83A (04) : 483 - 488
  • [3] Complications in dorsal percutaneous cannulated screw fixation of nondisplaced scaphoid waist fractures
    Bushnell, Brandon D.
    McWilliams, Andrew D.
    Messer, Terry M.
    [J]. JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2007, 32A (06): : 827 - 833
  • [4] Central screw placement in percutaneous screw scaphoid fixation: A cadaveric comparison of proximal and distal techniques
    Chan, KW
    McAdams, TR
    [J]. JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2004, 29A (01): : 74 - 79
  • [5] Coordinate systems for the carpal bones of the wrist
    Coburn, James C.
    Upal, Mohammad A.
    Crisco, Joseph J.
    [J]. JOURNAL OF BIOMECHANICS, 2007, 40 (01) : 203 - 209
  • [6] Crisco TJ, 1999, J ORTHOP RES, V17, P96
  • [7] Screw fixation of scaphoid fractures: A biomechanical assessment of screw length and screw augmentation
    Dodds, SD
    Panjabi, MM
    Slade, JF
    [J]. JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2006, 31A (03): : 405 - 413
  • [8] ON GRAY SCALE IMAGE MEASUREMENTS .2. SURFACE-AREA AND VOLUME
    EBERLY, D
    LANCASTER, J
    ALYASSIN, A
    [J]. CVGIP-GRAPHICAL MODELS AND IMAGE PROCESSING, 1991, 53 (06): : 550 - 562
  • [9] Computing moments of objects enclosed by piecewise polynomial surfaces
    Gonzalez-Ochoa, C
    McCammon, S
    Peters, J
    [J]. ACM TRANSACTIONS ON GRAPHICS, 1998, 17 (03): : 143 - 157
  • [10] Acute percutaneous scaphoid fixation - A pilot study
    Haddad, FS
    Goddard, NJ
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1998, 80B (01): : 95 - 99