Improved Isotopic Analysis With a Large Array of Gamma-Ray Microcalorimeters

被引:3
作者
Jethava, N. [1 ]
Ullom, J. N. [1 ]
Bennett, D. A. [1 ]
Doriese, W. B. [1 ]
Beall, J. A. [1 ]
Hilton, G. C. [1 ]
Horansky, R. D. [1 ]
Irwin, K. D. [1 ]
Sassi, E. [1 ]
Vale, L. R. [1 ]
Bacrania, M. K. [2 ]
Hoover, A. S. [2 ]
Karpius, P. J. [2 ]
Rabin, M. W. [2 ]
Rudy, C. R. [2 ]
Vo, D. T. [2 ]
机构
[1] Natl Inst Stand & Technol, Boulder, CO 80305 USA
[2] Los Alamos Natl Lab, Los Alamos, NM 87545 USA
关键词
Gamma-ray microcalorimeter; plutonium isotopics; SQUID multiplexing; transition edge sensor; TRANSITION-EDGE SENSORS; SQUID MULTIPLEXER; RESOLUTION;
D O I
10.1109/TASC.2009.2017945
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We present results from the largest array of gamma-ray microcalorimeters operated to date. The microcalorimeters consist of Mo/Cu transition-edge sensors with attached Sn absorbers. The detector array contains 66 pixels each with an active area 2.25 mm(2). Out of 66 pixels, 55 are active, and 31 were used to acquire a high statistics Pu gamma-ray spectrum. The energy resolution of the best 21 pixels was found to be 120 eV FWHM. The array is read out using time domain SQUID multiplexing. Here, we describe the multiplexing and present a high statistics Pu spectra. Because of the large collecting area of our array, the statistical error in the Pu-240 line intensity is approximately 0.7%, which is comparable to the systematic error in a measurement with a 500 eV germanium sensor. Hence, we have reached an important threshold for demonstrating improved isotopic measurements with microcalorimeter sensors. With straightforward changes, we plan to achieve a resolution of about 50 eV FWHM with 256 multiplexed detectors. Finally, we present early estimates of on-chip heating within our sensor array.
引用
收藏
页码:536 / 539
页数:4
相关论文
共 12 条
[1]   High-resolution gamma-ray spectrometers using bulk absorbers coupled to Mo/Cu multilayer superconducting transition-edge sensors [J].
Chow, DT ;
Loshak, A ;
van den Berg, ML ;
Frank, M ;
Barbee, TW ;
Labov, SE .
HARD X-RAY GAMMA-RAY AND NEUTRON DETECTOR PHYSICS II, 2000, 4141 :67-75
[2]   Progress toward kilopixel arrays: 3.8 eV microcalorimeter resolution in 8-channel SQUID multiplexer [J].
Doriese, WB ;
Beall, JA ;
Duncan, WD ;
Ferreira, L ;
Hilton, GC ;
Irwin, KD ;
Reintsema, CD ;
Ullom, JN ;
Vale, LR ;
Xu, Y .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 559 (02) :808-810
[3]   Time-division multiplexing of high-resolution x-ray microcalorimeters: Four pixels and beyond [J].
Doriese, WB ;
Beall, JA ;
Deiker, S ;
Duncan, WD ;
Ferreira, L ;
Hilton, GC ;
Irwin, KD ;
Reintsema, CD ;
Ullom, JN ;
Vale, LR ;
Xu, Y .
APPLIED PHYSICS LETTERS, 2004, 85 (20) :4762-4764
[4]  
Irwin KD, 2005, TOP APPL PHYS, V99, P63
[5]   In-focal-plane SQUID multiplexer [J].
Irwin, KD ;
Audley, MD ;
Beall, JA ;
Beyer, J ;
Deiker, S ;
Doriese, W ;
Duncan, W ;
Hilton, GC ;
Holland, W ;
Reintsema, CD ;
Ullom, JN ;
Vale, LR ;
Xu, YZ .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 520 (1-3) :544-547
[6]   SQUID multiplexers for transition-edge sensors [J].
Irwin, KD .
PHYSICA C-SUPERCONDUCTIVITY AND ITS APPLICATIONS, 2002, 368 (1-4) :203-210
[7]  
KARPIUS P, 2008, IEEE T NUCL SC UNPUB
[8]   Prototype system for superconducting quantum interference device multiplexing of large-format transition-edge sensor arrays [J].
Reintsema, CD ;
Beyer, J ;
Nam, SW ;
Deiker, S ;
Hilton, GC ;
Irwin, K ;
Martinis, J ;
Ullom, J ;
Vale, LR ;
Macintosh, M .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2003, 74 (10) :4500-4508
[9]  
RUDY C, 2007, P EUR SAF RES DEV AS
[10]   A frequency-domain read-out technique for large microcalorimeter arrays demonstrated using high-resolution γ-ray sensors [J].
Ullom, JN ;
Cunningham, MR ;
Miyazaki, T ;
Labov, SE ;
Clarke, J ;
Lanting, TM ;
Lee, AT ;
Richards, PL ;
Yoon, J ;
Spieler, H .
IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2003, 13 (02) :643-648