Source-detector calibration in three-dimensional Bayesian optical diffusion tomography

被引:39
作者
Oh, S
Milstein, AB
Millane, RP
Bouman, CA
Webb, KJ [1 ]
机构
[1] Purdue Univ, Sch Elect & Comp Engn, W Lafayette, IN 47907 USA
[2] Univ Canterbury, Dept Elect & Comp Engn, Christchurch 1, New Zealand
关键词
D O I
10.1364/JOSAA.19.001983
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Optical diffusion tomography is a method for reconstructing three-dimensional optical properties from light that passes through a highly scattering medium. Computing reconstructions from such data requires the solution of a nonlinear inverse problem. The situation is further complicated by the fact that while reconstruction algorithms typically assume exact knowledge of the optical source and detector coupling coefficients, these coupling coefficients are generally not available in practical measurement systems. A new method for estimating these unknown coupling coefficients in the three-dimensional reconstruction process is described. The joint problem of coefficient estimation and three-dimensional reconstruction is formulated in a Bayesian framework, and the resulting estimates are computed by using a variation of iterative coordinate descent optimization that is adapted for this problem. Simulations show that this approach is an accurate and efficient method for simultaneous reconstruction of absorption and diffusion coefficients as well as the coupling coefficients. A simple experimental result validates the approach. (C) 2002 Optical Society of America.
引用
收藏
页码:1983 / 1993
页数:11
相关论文
共 26 条
[11]   Quantitative optical image reconstruction of turbid media by use of direct-current measurements [J].
Iftimia, N ;
Jiang, HB .
APPLIED OPTICS, 2000, 39 (28) :5256-5261
[12]   Optical image reconstruction using DC data: Simulations and experiments [J].
Jiang, HB ;
Paulsen, KD ;
Osterberg, UL .
PHYSICS IN MEDICINE AND BIOLOGY, 1996, 41 (08) :1483-1498
[13]   Improved continuous light diffusion imaging in single- and multi-target tissue-like phantoms [J].
Jiang, HB ;
Paulsen, KD ;
Osterberg, UL ;
Patterson, MS .
PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (03) :675-693
[14]  
LANGE K, 1990, P SOC PHOTO-OPT INS, V1351, P270
[15]   Multispectral near-infrared tomography:: a case study in compensating for water and lipid content in hemoglobin imaging of the breast [J].
McBride, TO ;
Pogue, BW ;
Poplack, S ;
Soho, S ;
Wells, WA ;
Jiang, SD ;
Österberg, UL ;
Paulsen, KD .
JOURNAL OF BIOMEDICAL OPTICS, 2002, 7 (01) :72-79
[16]   Three-dimensional Bayesian optical diffusion tomography with experimental data [J].
Milstein, AB ;
Oh, S ;
Reynolds, JS ;
Webb, KJ ;
Bouman, CA ;
Millane, RP .
OPTICS LETTERS, 2002, 27 (02) :95-97
[17]  
MOHAMMADDJAFARI A, 1996, P IEEE INT C IM PROC, V2, P473
[18]  
MOHAMMADDJAFARI A, 1993, P IEEE INT C AC SPEE, P495
[19]   Contrast-detail analysis for detection and characterization with near-infrared diffuse tomography [J].
Pogue, BW ;
Willscher, C ;
McBride, TO ;
Österberg, UL ;
Paulsen, KD .
MEDICAL PHYSICS, 2000, 27 (12) :2693-2700
[20]   Quantitative hemoglobin tomography with diffuse near-infrared spectroscopy: Pilot results in the breast [J].
Pogue, BW ;
Poplack, SP ;
McBride, TO ;
Wells, WA ;
Osterman, KS ;
Osterberg, UL ;
Paulsen, KD .
RADIOLOGY, 2001, 218 (01) :261-266