The Impact of Torso Signal Processing on Noninvasive Electrocardiographic Imaging Reconstructions

被引:15
作者
Bear, Laura R. [1 ,2 ]
Dogrusoz, Yesim Serinagaoglu [3 ]
Good, Wilson [4 ,5 ]
Svehlikova, Jana [6 ]
Coll-Font, Jaume [7 ]
van Dam, Eelco [8 ]
MacLeod, Rob [4 ,5 ]
机构
[1] Univ Bordeaux, Fondat Bordeaux Univ, IHU LIRYC, F-33000 Bordeaux, France
[2] INSERM, CRCTB U1045, F-33000 Bordeaux, France
[3] Elect & Elect Engn Dept, Ankara, Turkey
[4] Univ Utah, Dept Biomed Engn, Salt Lake City, UT 84112 USA
[5] Univ Utah, SCI Inst, Salt Lake City, UT 84112 USA
[6] Slovak Acad Sci, Inst Measurement Sci, Bratislava, Slovakia
[7] Childrens Hosp, Computat Radiol Lab, 300 Longwood Ave, Boston, MA 02115 USA
[8] Peacs BV, Nieuwerbrug Aan Den Rijn, Netherlands
关键词
Finite impulse response filters; IIR filters; Torso; Band-pass filters; Electrodes; Image reconstruction; ECGI; inverse problem; PVC; Signal processing; Torso Tank;
D O I
10.1109/TBME.2020.3003465
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Goal: To evaluate state-of-the-art signal processing methods for epicardial potential-based noninvasive electrocardiographic imaging reconstructions of single-site pacing data. Methods: Experimental data were obtained from two torso-tank setups in which Langendorff-perfused hearts (n = 4) were suspended and potentials recorded simultaneously from torso and epicardial surfaces. 49 different signal processing methods were applied to torso potentials, grouped as i) high-frequency noise removal (HFR) methods ii) baseline drift removal (BDR) methods and iii) combined HFR+BDR. The inverse problem was solved and reconstructed electrograms and activation maps compared to those directly recorded. Results: HFR showed no difference compared to not filtering in terms of absolute differences in reconstructed electrogram amplitudes nor median correlation in QRS waveforms (p > 0.05). However, correlation and mean absolute error of activation times and pacing site localization were improved with all methods except a notch filter. HFR applied post-reconstruction produced no differences compared to pre-reconstruction. BDR and BDR+HFR significantly improved absolute and relative difference, and correlation in electrograms (p < 0.05). While BDR+HFR combined improved activation time and pacing site detection, BDR alone produced significantly lower correlation and higher localization errors (p < 0.05). Conclusion: BDR improves reconstructed electrogram morphologies and amplitudes due to a reduction in lambda value selected for the inverse problem. The simplest method (resetting the isoelectric point) is sufficient to see these improvements. HFR does not impact electrogram accuracy, but does impact post-processing to extract features such as activation times. Removal of line noise is insufficient to see these changes. HFR should be applied post-reconstruction to ensure over-filtering does not occur.
引用
收藏
页码:436 / 447
页数:12
相关论文
共 24 条
[1]   Application of robust Generalised Cross-Validation to the inverse problem of electrocardiology [J].
Barnes, Josef P. ;
Johnston, Peter R. .
COMPUTERS IN BIOLOGY AND MEDICINE, 2016, 69 :213-225
[2]   How Accurate Is Inverse Electrocardiographic Mapping? A Systematic In Vivo Evaluation [J].
Bear, Laura R. ;
LeGrice, Ian J. ;
Sands, Gregory B. ;
Lever, Nigel A. ;
Loiselle, Denis S. ;
Paterson, David J. ;
Cheng, Leo K. ;
Smaill, Bruce H. .
CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2018, 11 (05) :e006108
[3]   Cardiac electrical dyssynchrony is accurately detected by noninvasive electrocardiographic imaging [J].
Bear, Laura R. ;
Huntjens, Peter R. ;
Walton, Richard D. ;
Bernus, Olivier ;
Coronel, Ruben ;
Dubois, Remi .
HEART RHYTHM, 2018, 15 (07) :1058-1069
[4]   Single-Beat Noninvasive Imaging of Ventricular Endocardial and Epicardial Activation in Patients Undergoing CRT [J].
Berger, Thomas ;
Pfeifer, Bernhard ;
Hanser, Friedrich F. ;
Hintringer, Florian ;
Fischer, Gerald ;
Netzer, Michael ;
Trieb, Thomas ;
Stuehlinger, Markus ;
Dichtl, Wolfgang ;
Baumgartner, Christian ;
Pachinger, Otmar ;
Seger, Michael .
PLOS ONE, 2011, 6 (01)
[5]   Effects of material properties and geometry on electrocardiographic forward simulations [J].
Bradley, CP ;
Pullan, AJ ;
Hunter, PJ .
ANNALS OF BIOMEDICAL ENGINEERING, 2000, 28 (07) :721-741
[6]   Effects of experimental and modeling errors on electrocardiographic inverse formulations [J].
Cheng, LK ;
Bodley, JM ;
Pullan, AJ .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2003, 50 (01) :23-32
[7]  
Cluitmans Matthijs J M, 2017, JACC Clin Electrophysiol, V3, P232, DOI 10.1016/j.jacep.2016.11.012
[8]   Non-invasive cardiac mapping in clinical practice: Application to the ablation of cardiac arrhythmias [J].
Dubois, Remi ;
Shah, Ashok J. ;
Hocini, Meleze ;
Denis, Arnaud ;
Derval, Nicolas ;
Cochet, Hubert ;
Sacher, Frederic ;
Bear, Laura ;
Duchateau, Josselin ;
Jais, Pierre ;
Haissaguerre, Michel .
JOURNAL OF ELECTROCARDIOLOGY, 2015, 48 (06) :966-974
[9]  
Duchateau J., IEEE T BIOMED ENG, V64, P1
[10]   Performance and limitations of noninvasive cardiac activation mapping [J].
Duchateau, Josselin ;
Sacher, Frederic ;
Pambrun, Thomas ;
Derval, Nicolas ;
Chamorro-Servent, Judit ;
Denis, Arnaud ;
Ploux, Sylvain ;
Hocini, Meleze ;
Jais, Pierre ;
Bernus, Olivier ;
Haissaguerre, Michel ;
Dubois, Remi .
HEART RHYTHM, 2019, 16 (03) :435-442