Calibration of a liquid scintillation counter to assess tritium levels in various samples

被引:2
作者
Al-Haddad, MN [1 ]
Fayoumi, AH [1 ]
Abu-Jarad, FA [1 ]
机构
[1] King Fahd Univ Petr & Minerals, Ctr Appl Phys Sci, Dhahran 31261, Saudi Arabia
关键词
liquid scintillation counter; calibration; tritium; bioassay; smear; oil;
D O I
10.1016/S0168-9002(99)00272-7
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
An LKB-Wallac 1217 Liquid Scintillation Counter (LSC) was calibrated with a newly adopted cocktail. The LSC was then used to measure tritium levels in various samples to assess the compliance of tritium levels with the recommended international levels, The counter was calibrated to measure both biological and operational samples for personnel and for an accelerator facility at KFUPM. The biological samples include the bioassay (urine), saliva, and nasal tests. The operational samples of the light ion linear accelerator include target cooling water, organic oil, fomblin oil, and smear samples. Sets of standards, which simulate various samples, were fabricated using traceable certified tritium standards. The efficiency of the counter was obtained for each sample. The typical range of the efficiencies varied from 33% for smear samples down to 1.5% far organic oil samples. A quenching curve for each sample is presented. The minimum detectable activity for each sample was established. Typical tritium levels in biological and operational values are presented. All measured values are far below the recommended international limits. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:356 / 361
页数:6
相关论文
共 10 条
[1]   KFUPM FAST-NEUTRON ACTIVATION-ANALYSIS FACILITY [J].
AKSOY, A ;
NAQVI, AA ;
KHIARI, FZ ;
RAASHID, M ;
COBAN, A ;
ABDELAAL, RE ;
ALJUWAIR, H .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1993, 332 (03) :506-510
[2]   350-KEV ACCELERATOR FACILITY FOR THE UNIVERSITY-OF-PETROLEUM-AND-MINERALS [J].
ALJUWAIR, H ;
BLUME, G ;
JAARSMA, RJ ;
MEITZLER, CR ;
PURSER, KH .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1987, 24-5 :810-812
[3]  
*AM NAT STAND I, 1994, HLTH PHYS
[4]  
[Anonymous], 1996, IAEA SAF SER
[5]   A comparison of four aqueous-miscible liquid scintillation cocktails with an alpha/beta discriminating Wallac 1415 liquid scintillation counter [J].
DeVol, TA ;
Brown, DD ;
Leyba, JD ;
Fjeld, RA .
HEALTH PHYSICS, 1996, 70 (01) :41-46
[6]  
DYER A, 1980, LIQUID SCINTILLATION
[7]  
*LKB, LKB WALL OP INSTR RA
[8]  
MEECHAN P, 1979, HLTH PHYS, V73, P808
[9]  
PETERMAN BF, 1982, RADIAT PROT DOSIM, V3, P129
[10]  
SURETTE RA, 1995, FUSION TECHNOL, V28, P958