Hilbert-huang transform based islanding detection scheme for Distributed generation

被引:0
作者
Chaitanya, B. K. [1 ]
Yadav, Anamika [1 ]
机构
[1] NIT Raipur, Dept Elect Engn, Raipur, CG, India
来源
2018 IEEE 8TH POWER INDIA INTERNATIONAL CONFERENCE (PIICON) | 2018年
关键词
Distributed generation; Hilbert-huang transform; Islanding detection; Non-islanding switching events; Non-detection zone; Noise; PERFORMANCE; RELAYS; ROCOF;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This study presents a passive anti-islanding technique for distributed generation using Hilbert-Huang Transform (HHT). The voltage and current signals measured at point of common coupling of the distributed generator are processed through HHT to detect the islanding. Empirical mode decomposition (EMD) in combination with Hilbert transform can be termed as HHT. First, the EMD decomposes the signal into various intrinsic modes. Hilbert transformation is further performed over the modes extracted through EMD to obtain the analytic signal. Ratio index of voltage and current computed through HUT is used for identifying the islanding condition. Different simulation studies were performed during islanding condition with different power mismatches and also for non-islanding switching events. It is found that there is a reduction in non-detection zone compared to conventional rate of change of frequency (ROCOF) relay.
引用
收藏
页数:5
相关论文
共 22 条
[1]  
[Anonymous], 2011, Integration of Distributed Generation In The Power System
[2]  
[Anonymous], 2004, IEEE PES M
[3]  
Bower W., 2002, Evaluation of islanding detection methods for utility-interactive inverters in photovoltaic systems
[4]  
Dubey Rahul, 2018, IET GENER TRANSCO DI
[5]   Mathematical morphology-based islanding detection for distributed generation [J].
Farhan, Musliyarakath Aneesa ;
Swarup, K. Shanti .
IET GENERATION TRANSMISSION & DISTRIBUTION, 2016, 10 (02) :518-525
[6]   Comparative analysis between ROCOF and vector surge relays for distributed generation applications [J].
Freitas, W ;
Xu, WS ;
Affonso, CM ;
Huang, ZY .
IEEE TRANSACTIONS ON POWER DELIVERY, 2005, 20 (02) :1315-1324
[7]  
Funabashi T., 2003, Power Tech Conference Proceedings, 2003 IEEE Bologna, V2, P6, DOI DOI 10.1109/PTC.2003.1304617
[8]   Microgrid protection using Hilbert-Huang transform based-differential scheme [J].
Gururani, Ashika ;
Mohanty, Soumya R. ;
Mohanta, Jagadish Chandra .
IET GENERATION TRANSMISSION & DISTRIBUTION, 2016, 10 (15) :3707-3716
[9]   Enhancement of islanding-detection of distributed generation systems via wavelet transform-based approaches [J].
Hsieh, Cheng-Tao ;
Lin, Jeu-Min ;
Huang, Shyh-Jier .
INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2008, 30 (10) :575-580
[10]   An islanding detection method for distributed generations using voltage unbalance and total harmonic distortion of current [J].
Jang, SI ;
Kim, KH .
IEEE TRANSACTIONS ON POWER DELIVERY, 2004, 19 (02) :745-752