Ion temperature and fluctuation in a large-diameter electron-cyclotron-resonance plasma

被引:6
|
作者
Koga, M [1 ]
Yoshizawa, T
Ueda, Y
Yonesu, A
Kawai, Y
机构
[1] Kyushu Univ, Interdisciplinary Grad Sch Engn Sci, Kasuga, Fukuoka 8168580, Japan
[2] Univ Ryukyus, Dept Elect & Elect Engn, Fac Engn, Nishihara, Okinawa 9030213, Japan
关键词
ECR plasma; ion temperature; optical emission spectroscopy; fluctuation;
D O I
10.1016/S0042-207X(02)00139-2
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Using high-resolution optical emission spectroscopy, Ar+ ion temperature in a large-diameter electron cyclotron resonance (ECR) plasma was obtained from Doppler broadenings. It was found that the ion temperature depends on gas pressures and incident microwave powers. The ion temperature at low-pressures was considerably high. When the gas pressure was decreased from 13.0 x 10(-2) to 2.6 x 10(-2) Pa for the incident microwave power of 2.0 kW, the ion temperature increased from 0.03 to 0.56 eV. The amplitude of fluctuations observed in the ECR plasma also increased with decreasing the gas pressure and increasing the incident microwave power. These results suggest that there is a correlation between the ion temperature and fluctuations. The fluctuations were excited by the flute instability. (C) 2002 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:329 / 334
页数:6
相关论文
共 50 条
  • [31] Characteristics of a large diameter reactive ion beam generated by an electron cyclotron resonance microwave plasma source
    Geisler, S
    Brockhaus, A
    Engemann, J
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY A-VACUUM SURFACES AND FILMS, 2001, 19 (02): : 539 - 546
  • [32] ELECTRON AND ION ENERGIES IN PLASMAS GENERATED BY THE ELECTRON-CYCLOTRON-RESONANCE MECHANISM
    UHM, HS
    CHANG, HY
    KIM, JH
    SONG, SK
    PHYSICS OF PLASMAS, 1995, 2 (03) : 991 - 1001
  • [34] LARGE-AREA ELECTRON-CYCLOTRON-RESONANCE PLASMA SOURCE WITH PERMANENT-MAGNETS
    SHIDA, N
    INOUE, T
    KOKAI, H
    SAKAMOTO, Y
    MIYAZAWA, W
    DEN, S
    HAYASHI, Y
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 2-LETTERS, 1993, 32 (11A): : L1635 - L1637
  • [35] Operation of an electron-cyclotron-resonance ion source with supplemental electron injection
    Boscolo, I
    Cialdi, S
    Gammino, S
    Ciavola, G
    PHYSICAL REVIEW SPECIAL TOPICS-ACCELERATORS AND BEAMS, 2003, 6 (07):
  • [36] WAVE-PROPAGATION AND PLASMA UNIFORMITY IN AN ELECTRON-CYCLOTRON-RESONANCE PLASMA
    SAMUKAWA, S
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY A, 1993, 11 (05): : 2572 - 2576
  • [37] SIGE GATE OXIDE PREPARED AT LOW-TEMPERATURE IN AN ELECTRON-CYCLOTRON-RESONANCE PLASMA
    LI, PW
    YANG, ES
    APPLIED PHYSICS LETTERS, 1993, 63 (21) : 2938 - 2940
  • [38] DAMAGE AND CONTAMINATION IN LOW-TEMPERATURE ELECTRON-CYCLOTRON-RESONANCE PLASMA-ETCHING
    WHANG, KW
    LEE, SH
    DOH, HH
    KIM, JS
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY A-VACUUM SURFACES AND FILMS, 1994, 12 (06): : 3091 - 3094
  • [39] THE SUPERCONDUCTING ELECTRON-CYCLOTRON-RESONANCE 6.4 GHZ HIGH-B MODE AND FREQUENCY SCALING IN ELECTRON-CYCLOTRON-RESONANCE ION SOURCES
    ANTAYA, TA
    GAMMINO, S
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1994, 65 (05): : 1723 - 1727
  • [40] Modeling of electron-cyclotron-resonance ion source and scaling laws
    Girard, A.
    Perret, C.
    Melin, G.
    Lecot, C.
    Review of Scientific Instruments, 1998, 69 (2 pt 2):