Experimental investigation on binary ammonia-water and ternary ammonia-water-lithium bromide mixture-based absorption refrigeration systems for fishing ships

被引:33
|
作者
Yuan, Han [1 ]
Zhang, Ji [1 ]
Huang, Xiankun [1 ]
Mei, Ning [1 ]
机构
[1] Ocean Univ China, Coll Engn, Marine Engn, 238 Songling Rd, Qingdao 266100, Peoples R China
基金
中国国家自然科学基金;
关键词
Ship; Exhaust heat recovery; Absorption refrigeration; Ammonia-water-lithium bromide; Ammonia-water; Experimental investigation; VAPOR-LIQUID-EQUILIBRIA; WASTE HEAT; EXHAUST-GAS; DIESEL-ENGINE; OPTIMIZATION; PERFORMANCE; RECOVERY; CYCLE; NH3+H2O+LIBR; VESSELS;
D O I
10.1016/j.enconman.2018.04.013
中图分类号
O414.1 [热力学];
学科分类号
摘要
Heat recovery of marine engine exhaust gas is an effective way of improving the onboard fuel economy and environmental compliance of fishing ships. Among such heat recovery techniques, the absorption refrigeration cycle shows potential as it can convert the exhaust thermal energy into refrigeration output and meet the onboard refrigeration requirement. However, the severe operating conditions on the shipboard poses a great challenge for its application. This paper presents an experimental investigation of an absorption refrigeration system for the heat recovery of marine engine exhaust gas. To overcome the adverse effect of the severe onboard condition on the rectification process of the absorption refrigeration system, a ternary ammonia-water-lithium bromide mixture is selected as the working fluid. A prototype of the absorption system is designed and an experimental investigation is conducted. Then, the performances of both the ternary ammonia-water-lithium bromide-based system and binary ammonia-water-based system are compared. The results show that the rectifier heat exchange area can be reduced by approximately 16% under the experimental working condition. Furthermore, the ternary system operates at a relatively lower pressure, with a refrigeration temperature of less than -15.0 degrees C, which is higher compared to the temperature of less than - 23.6 degrees C associated with the binary system. Nevertheless, the ternary system achieves a remarkably higher cooling capacity. Moreover, by using the ternary ammonia-water-lithium bromide mixture, the heat loss of the prototype is reduced while the coefficient of performance and electric coefficient of performance are increased, indicating that the ternary system has a higher energy conversion efficiency.
引用
收藏
页码:13 / 22
页数:10
相关论文
共 27 条
  • [1] Experimental investigation on an ammonia-water-lithium bromide absorption refrigeration system without solution pump
    Wu, Tiehui
    Wu, Yuyuan
    Yu, Zhiqiang
    Zhao, Haichen
    Wu, Honglin
    ENERGY CONVERSION AND MANAGEMENT, 2011, 52 (05) : 2314 - 2319
  • [2] Analysis of ammonia/water and ammonia/salt mixture absorption cycles for refrigeration purposes in fishing ships
    Taboas, Francisco
    Bourouis, Mahmoud
    Valles, Manel
    APPLIED THERMAL ENGINEERING, 2014, 66 (1-2) : 603 - 611
  • [3] Ammonia-water absorption refrigeration systems with flooded evaporators
    Fernandez-Seara, Jose
    Sieres, Jaime
    APPLIED THERMAL ENGINEERING, 2006, 26 (17-18) : 2236 - 2246
  • [4] Experimental investigation of mass transfer performance with some random packings for ammonia rectification in ammonia-water absorption refrigeration systems
    Sieres, Jaime
    Fernandez-Seara, Jose
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2007, 46 (07) : 699 - 706
  • [5] Computer simulation and optimization of ammonia-water absorption refrigeration systems
    Sun, DW
    ENERGY SOURCES, 1997, 19 (07): : 677 - 690
  • [6] Industrial trigeneration using ammonia-water absorption refrigeration systems (AAR)
    Colonna, P
    Gabrielli, S
    APPLIED THERMAL ENGINEERING, 2003, 23 (04) : 381 - 396
  • [7] Distillation column configurations in ammonia-water absorption refrigeration systems
    Fernández-Seara, J
    Sieres, J
    Vázquez, M
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2003, 26 (01): : 28 - 34
  • [8] Mass transfer characteristics of a structured packing for ammonia rectification in ammonia-water absorption refrigeration systems
    Sieres, Jaime
    Fernandez-Seara, Jose
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2007, 30 (01): : 58 - 67
  • [9] Experimental study of an ammonia-water bubble absorber using a plate heat exchanger for absorption refrigeration machines
    Cerezo, Jesus
    Bourouis, Mahmoud
    Valles, Manel
    Coronas, Alberto
    Best, Roberto
    APPLIED THERMAL ENGINEERING, 2009, 29 (5-6) : 1005 - 1011
  • [10] Simultaneous heat and mass transfer of a packed distillation column for ammonia-water absorption refrigeration systems
    Fernández-Seara, J
    Sieres, J
    Vázquez, M
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2002, 41 (10) : 927 - 935