A Meal Detection Algorithm for the Artificial Pancreas: A Randomized Controlled Clinical Trial in Adolescents With Type 1 Diabetes

被引:19
作者
Palisaitis, Emilie [1 ]
El Fathi, Anas [2 ]
von Oettingen, Julia E. [3 ,4 ]
Haidar, Ahmad [1 ,4 ]
Legault, Laurent [3 ,4 ]
机构
[1] McGill Univ, Dept Biomed Engn, Montreal, PQ, Canada
[2] McGill Univ, Dept Elect & Comp Engn, Montreal, PQ, Canada
[3] Montreal Childrens Hosp, Dept Endocrinol, Dept Pediat, Montreal, PQ, Canada
[4] McGill Univ, Hlth Ctr, Res Inst, Montreal, PQ, Canada
关键词
BOLUS; CHILDREN;
D O I
10.2337/dc20-1232
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVE We developed a meal detection algorithm for the artificial pancreas (AP+MDA) that detects unannounced meals and delivers automatic insulin boluses. RESEARCH DESIGN AND METHODS We conducted a randomized crossover trial in 11 adolescents aged 12-18 years with HbA(1c) >= 7.5% who missed one or more boluses in the past 6 months. We compared 1) continuous subcutaneous insulin infusion (CSII), 2) artificial pancreas (AP), and 3) AP+MDA. Participants underwent three 9-h interventions involving breakfast with a bolus and lunch without a bolus. RESULTS In AP+MDA, the meal detection time was 40.0 (interquartile range 40.0-57.5) min. Compared with CSII, AP+MDA decreased the 4-h postlunch incremental area under the curve (iAUC) from 24.1 +/- 9.5 to 15.4 +/- 8.0 h . mmol/L (P = 0.03). iAUC did not differ between AP+MDA and AP (19.6 +/- 10.4 h . mmol/L, P = 0.21) or between AP and CSII (P = 0.33). The AP+MDA reduced time >10 mmol/L (58.0 +/- 26.6%) compared with CSII (79.6 +/- 27.5%, P = 0.02) and AP (74.2 +/- 20.6%, P = 0.047). CONCLUSIONS The AP+MDA improved glucose control after an unannounced meal.
引用
收藏
页码:604 / 606
页数:3
相关论文
共 10 条
[1]   Missed insulin meal boluses and elevated hemoglobin A1c levels in children receiving insulin pump therapy [J].
Burdick, J ;
Chase, HP ;
Slover, RH ;
Knievel, K ;
Scrimgeour, L ;
Maniatis, AK ;
Klingensmith, GJ .
PEDIATRICS, 2004, 113 (03) :E221-E224
[2]   The use of insulin pumps with meal bolus alarms in children with type 1 diabetes to improve glycemic control [J].
Chase, HP ;
Horner, B ;
McFann, K ;
Yetzer, H ;
Gaston, J ;
Banion, C ;
Fiallo-Scharer, R ;
Slover, R ;
Klingensmith, G .
DIABETES CARE, 2006, 29 (05) :1012-1015
[3]   Use of an artificial pancreas among adolescents for a missed snack bolus and an underestimated meal bolus [J].
Chernavvsky, Daniel R. ;
DeBoer, Mark D. ;
Keith-Hynes, Patrick ;
Mize, Benton ;
McElwee, Molly ;
Demartini, Susan ;
Dunsmore, Spencer F. ;
Wakeman, Christian ;
Kovatchev, Boris P. ;
Breton, Marc D. .
PEDIATRIC DIABETES, 2016, 17 (01) :28-35
[4]   An Unannounced Meal Detection Module for Artificial Pancreas Control Systems [J].
El Fathi, Anas ;
Palisaitis, Emilie ;
Boulet, Benoit ;
Legault, Laurent ;
Haidar, Ahmad .
2019 AMERICAN CONTROL CONFERENCE (ACC), 2019, :4130-4135
[5]   Safety of closed-loop therapy during reduction or omission of meal boluses in adolescents with type 1 diabetes: a randomized clinical trial [J].
Elleri, D. ;
Maltoni, G. ;
Allen, J. M. ;
Nodale, M. ;
Kumareswaran, K. ;
Leelarathna, L. ;
Thabit, H. ;
Caldwell, K. ;
Wilinska, M. E. ;
Calhoun, P. ;
Kollman, C. ;
Dunger, D. B. ;
Hovorka, Roman .
DIABETES OBESITY & METABOLISM, 2014, 16 (11) :1174-1178
[6]   Closed-Loop Basal Insulin Delivery Over 36 Hours in Adolescents With Type 1 Diabetes [J].
Elleri, Daniela ;
Allen, Janet M. ;
Kumareswaran, Kavita ;
Leelarathna, Lalantha ;
Nodale, Marianna ;
Caldwell, Karen ;
Cheng, Peiyao ;
Kollman, Craig ;
Haidar, Ahmad ;
Murphy, Helen R. ;
Wilinska, Malgorzata E. ;
Acerini, Carlo L. ;
Dunger, David B. ;
Hovorka, Roman .
DIABETES CARE, 2013, 36 (04) :838-844
[7]   Poor adherence to integral daily tasks limits the efficacy of CSII in youth [J].
O'Connell, M. A. ;
Donath, S. ;
Cameron, F. J. .
PEDIATRIC DIABETES, 2011, 12 (06) :556-559
[8]   Missed bolus doses: devastating for metabolic control in CSII-treated adolescents with type 1 diabetes [J].
Olinder, Anna Lindholm ;
Kernell, Anna ;
Smide, Bibbi .
PEDIATRIC DIABETES, 2009, 10 (02) :142-148
[9]   Insulin Administration and Rate of Glucose Appearance in People With Type 1 Diabetes [J].
Pennant, Mary E. ;
Bluck, Leslie J. C. ;
Marcovecchio, M. Loredana ;
Salgin, Burak ;
Hovorka, Roman ;
Dunger, David B. .
DIABETES CARE, 2008, 31 (11) :2183-2187
[10]   Examining the Relationship Between Pre- and Postprandial Glucose Levels and Insulin Bolus Timing Using Bluetooth-Enabled Insulin Pen Cap Technology and Continuous Glucose Monitoring [J].
Toschi, Elena ;
Slyne, Christine ;
Greenberg, Jordan M. ;
Greaves, Tori ;
Atakov-Castillo, Astrid ;
Carl, Sam ;
Dufour, Alyssa B. ;
Munshi, Medha .
DIABETES TECHNOLOGY & THERAPEUTICS, 2020, 22 (01) :19-24