Influence of component alignment on outcome for unicompartmental knee replacement

被引:69
作者
Gulati, A. [1 ]
Chau, R. [1 ]
Simpson, D. J. [1 ]
Dodd, C. A. F. [2 ]
Gill, H. S. [1 ]
Murray, D. W. [1 ,2 ]
机构
[1] Univ Oxford, Nuffield Dept Orthopaed Surg, Oxford OX3 7LD, England
[2] Nuffield Orthopaed Ctr NHS Trust, Oxford OX3 7LD, England
关键词
Unicompartmental component alignment; UKR; Outcome; ARTHROPLASTY; RECOVERY; SURVIVAL; SURGERY;
D O I
10.1016/j.knee.2008.11.001
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
This study's aim was to assess the effect of component mal-alignment on outcome of Oxford Unicompartmental Knee Replacement (UKR). Two hundred and eleven knees implanted with a medial UKR, using a minimally invasive approach, were followed up at a minimum of 4 years. Sagittal and frontal plane femoral and tibial component alignments were determined from antero-posterior and lateral radiographs. The cohort was divided into alignment groups which represented consecutive 2.5 degrees intervals over the range of measured values for femoral varus/valgus, femoral flexion/extension, tibial varus/valgus and tibial tilt. The Oxford Knee Score (OKS) and incidence of radiolucency (RL) were compared between alignment groups for each alignment parameter. In 98% of cases the femoral components were positioned between 10 degrees varus and 10 degrees valgus; all femoral components were within +/- 10 degrees flexion. In 92% of cases the tibial components were positioned between +/- 5 degrees varus/valgus and superior/inferior tilt (neutral tilt being 7 degrees). Within these ranges there were no significant differences in OKS or RL between the alignment groups; nor were there any differences between those at the extremes of component alignment compared to those in the inner ranges of alignment. We conclude that, because of the spherical femoral component, the Oxford UKR is tolerant to femoral mal-alignment of 10 degrees and tibial mal-alignment of 5 degrees. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:196 / 199
页数:4
相关论文
共 19 条
[1]   The effect of component malalignment on the clinical and radiological outcome of the Kinemax total knee replacement [J].
Bankes, MJK ;
Back, DL ;
Cannon, SR ;
Briggs, TWR .
KNEE, 2003, 10 (01) :55-60
[2]  
CARR A, 1993, CLIN ORTHOP RELAT R, P205
[3]  
Daubresse Francois, 2005, Acta Orthop Belg, V71, P710
[4]   Questionnaire on the perceptions of patients about total knee replacement [J].
Dawson, J ;
Fitzpatrick, R ;
Murray, D ;
Carr, A .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1998, 80B (01) :63-69
[5]   Implant position in knee surgery - A comparison of minimally invasive, open unicompartmental and total knee arthroplasty [J].
Fisher, DA ;
Watts, M ;
Davis, KE .
JOURNAL OF ARTHROPLASTY, 2003, 18 (07) :2-8
[6]  
Goodfellow J., 2006, UNICOMPARTMENTAL ART
[7]  
Kasodekar V. B., 2006, SMJ Singapore Medical Journal, V47, P796
[8]  
LARSSON SE, 1988, CLIN ORTHOP RELAT R, P174
[9]  
McAuley JP, 2001, CLIN ORTHOP RELAT R, P279
[10]   Unicompartmental knee arthroplasty - Functional recovery and radiographic results with a minimally invasive technique [J].
Mullaji, Arun B. ;
Sharma, Amit ;
Marawar, Satyajit .
JOURNAL OF ARTHROPLASTY, 2007, 22 (04) :7-11