Reliability of a standardized protocol to calculate cross-sectional chest area and severity indices to evaluate pectus excavatum

被引:48
作者
Lawson, M. Louise
Barnes-Eley, Myra
Burke, Bonnie L.
Mitchell, Karen
Katz, Michael E.
Dory, Christopher L.
Miller, Stephen F.
Nuss, Donald
Croitoru, Daniel P.
Goretsky, Michael J.
Kelly, Robert E., Jr.
机构
[1] Childrens Hosp Kings Daughters, Ctr Pediat Res, Norfolk, VA USA
[2] Cincinnati Childrens Hosp, Dept Surg, Ctr Biostat & Epidemiol, Cincinnati, OH USA
[3] Med Ctr, Cincinnati, OH USA
[4] Univ Cincinnati, Cincinnati, OH USA
[5] Eastern Virginia Med Sch, Dept Pediat Epidemiol & Biometry Core, Norfolk, VA 23501 USA
[6] Imaging Consultants S Florida, Dept Radiol, W Boca Raton Med Ctr, Boca Raton, FL USA
[7] Childrens Hosp Kings Daughters, Dept Radiol, Dept Radiol, Norfolk, VA USA
[8] Hosp Sick Children, Toronto, ON M5G 1X8, Canada
[9] Childrens Hosp Kings Daughters, Eastern Virginia Med Sch, Dept Surg, Norfolk, VA USA
关键词
pectus excavatum; CT scan; Haller index; asymmetry; surgical outcomes;
D O I
10.1016/j.jpedsurg.2006.03.003
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Purpose: In evaluating the impact of surgical repair of pectus excavatum, the Haller index developed for preoperative decision-making purposes may be inadequate to quantity postoperative changes in shape of the chest. Individual patients may also have chest characteristics that impact the Success of repair, many of Which Would be unlikely to be measured by the Haller index alone. We have developed a protocol that measures the cross-sectional chest area and the asymmetry index along with the Haller index to more completely quantity the nature of the deformity. The purpose of this study was to determine the reliability of this protocol in the interpretation of chest completed tomography images from multiple sites. The protocol was developed as part of a multicenter study of clinical outcomes after surgical repair of pectus excavatum. Methods: Two radiologists independently selected 5 images from each of 32 computed tomography scans from multicenter study participants according to the protocol. A digitizer was used to measure the diameters and cross-sectional areas of the images selected; these results were used to calculate the Haller and a symmetry indices. The protocol was tested for intradigitizer and interradiologist reliability. Using the Haller and asymmetry indices, we also assessed agreement between radiologists classifying patients as abnormal. Results: Agreement was uniformly high for all comparisons (all Lin's concordance coefficients > 0.99 and all Cohen's kappa's > 0.85, all agreement on classification of patients > 95%) indicating almost perfect agreement. Disagreement on classification of patients using the Haller and asymmetry index was at the cut points for abnormality. Conclusion: The protocol was found to be a highly reliable method for deriving the cross-sectional area of the chest and the Haller and asymmetry indices and for classifying patients for surgical eligibility. Borderline cases should be examined carefully to determine the appropriateness of surgical intervention. Cross-sectional area can be measured reliably using this protocol and thus may be useful in quantifying the success of surgical intervention. (c) 2006 Elsevier Inc. All rights reserved.
引用
收藏
页码:1219 / 1225
页数:7
相关论文
共 8 条
[1]  
BURCHILL S, SIMPLE BOOTSTRAP MET
[2]  
Chung C S, 1975, Birth Defects Orig Artic Ser, V11, P1
[3]   CORRECTION OF PECTUS EXCAVATUM WITHOUT PROSTHESES OR SPLINTS - OBJECTIVE MEASUREMENT OF SEVERITY AND MANAGEMENT OF ASYMMETRICAL DEFORMITIES [J].
HALLER, JA ;
SHERMETA, DW ;
TEPAS, JJ ;
BITTNER, HR ;
GOLLADAY, ES .
ANNALS OF THORACIC SURGERY, 1978, 26 (01) :73-79
[4]   USE OF CT SCANS IN SELECTION OF PATIENTS FOR PECTUS EXCAVATUM SURGERY - A PRELIMINARY-REPORT [J].
HALLER, JA ;
KRAMER, SS ;
LIETMAN, SA .
JOURNAL OF PEDIATRIC SURGERY, 1987, 22 (10) :904-906
[5]   Measurement of observer agreement [J].
Kundel, HL ;
Polansky, M .
RADIOLOGY, 2003, 228 (02) :303-308
[6]  
LAWSON ML, IN PRESS J PEDIAT SU
[7]  
LAWSON ML, 2003, J PEDIAT SURG
[8]  
CLIN POLICY B, V272