Active power line conditioner planning using an enhanced optimal harmonic power flow method

被引:10
作者
Hong, YY [1 ]
Hsu, YL [1 ]
Chen, YT [1 ]
机构
[1] Chung Yuan Univ, Dept Elect Engn, Chungli 320, Taiwan
关键词
APLC; harmonics; optimization;
D O I
10.1016/S0378-7796(99)00020-6
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The active power Line conditioner (APLC) is a type of active power filter that compensates the voltage waveform distortion caused by harmonics in power systems. This paper presents a new approach based on the authors' previously presented two-level algorithm, optimal harmonic power flow (OHPF), to investigate the determination of locations and sizes of APLCs: the master level determines the compensator/tap settings and the new APLC locations/sizes; the slave level includes subproblems which involve cases of fundamental and harmonic frequencies separately. The objective is to minimize the new APLC injection currents, the voltage distortion, and the KW losses while satisfying the power flow equations, the harmonic power flow equations, the security constraints, and the harmonic standard. Test results for an 18-bus distribution system show the applicability of the proposed method. (C) 1999 Elsevier Science S.A. All rights reserved.
引用
收藏
页码:181 / 188
页数:8
相关论文
共 21 条
[11]  
Geoffrion A. M., 1972, Journal of Optimization Theory and Applications, V10, P237, DOI 10.1007/BF00934810
[12]  
Gill M., 1981, Practical Optimization
[13]   THE APPLICATION OF NETWORK OBJECTIVE FUNCTIONS FOR ACTIVELY MINIMIZING THE IMPACT OF VOLTAGE HARMONICS IN POWER-SYSTEMS [J].
GRADY, WM ;
SAMOTYJ, MJ ;
NOYOLA, AH ;
ELAMIN, IM ;
MASOUM, MAS ;
FUCHS, EF .
IEEE TRANSACTIONS ON POWER DELIVERY, 1992, 7 (03) :1379-1386
[14]   MINIMIZING NETWORK HARMONIC VOLTAGE DISTORTION WITH AN ACTIVE POWER-LINE CONDITIONER [J].
GRADY, WM ;
SAMOTYJ, MJ ;
NOYOLA, AH .
IEEE TRANSACTIONS ON POWER DELIVERY, 1991, 6 (04) :1690-1697
[15]   SURVEY OF ACTIVE POWER-LINE CONDITIONING METHODOLOGIES [J].
GRADY, WM ;
SAMOTYJ, MJ ;
NOYOLA, AH .
IEEE TRANSACTIONS ON POWER DELIVERY, 1990, 5 (03) :1536-1542
[16]  
HEYDT GT, 1983, HARMONIC POWER FLOW, V1
[17]   Optimal harmonic power flow [J].
Hong, YY .
IEEE TRANSACTIONS ON POWER DELIVERY, 1997, 12 (03) :1267-1274
[18]   Determination of locations and sizes for active power line conditioners to reduce harmonics in power systems [J].
Hong, YY ;
Chang, YK .
IEEE TRANSACTIONS ON POWER DELIVERY, 1996, 11 (03) :1610-1617
[19]   A Study of Active Power Filters Using Quad-Series Voltage-Source PWM Converters for Harmonic Compensation [J].
Peng, Fang-Zhang ;
Akagi, Hirofumi ;
Nabae, Akira .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 1990, 5 (01) :9-15
[20]   OPTIMAL POWER FLOW BY NEWTON APPROACH [J].
SUN, DI ;
ASHLEY, B ;
BREWER, B ;
HUGHES, A ;
TINNEY, WF .
IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1984, 103 (10) :2864-2880