Liquid-Liquid Extraction in a Rotating-Spray Column: Removal of Cr(VI) by Aliquat 336

被引:17
作者
Bonam, D. [1 ]
Bhattacharyya, G. [1 ]
Bhowal, A. [1 ]
Datta, S. [1 ]
机构
[1] Jadavpur Univ, Dept Chem Engn, Kolkata 700032, India
关键词
MASS-TRANSFER; CENTRIFUGAL EXTRACTOR; CONTINUOUS PHASE; EQUILIBRIUM;
D O I
10.1021/ie900012k
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
The effect of centrifugal force on mass-transfer rates in liquid-liquid extraction was investigated experimentally in a rotating-spray column. Extraction with interfacial chemical reaction was studied in this contactor by countercurrent contact Of a dilute aqueous solution of hexavalent chromium (pH 2) with an extractant-Aliquat 336 (quaternary ammonium salt)-dissolved in kerosene (dispersed phase). The overall volumetric mass-transfer coefficient, based oil a continuous phase (assuming plug flow of the phases), was measured to be all order higher than that in a conventional spray column. A mathematical model was developed for this contactor, considering axial dispersion in the continuous phase and internal circulation within drops. Simulation results suggested that the variation of k(c)a, relative to the flow rate of the aqueous phase, was not significant at a constant rotor speed and a constant flow rate of the organic phase.
引用
收藏
页码:7687 / 7693
页数:7
相关论文
共 29 条
  • [1] EXTRACTION OF CR(VI) WITH ALIQUAT-336 IN HOLLOW-FIBER CONTACTORS - MASS-TRANSFER ANALYSIS AND MODELING
    ALONSO, AI
    URTIAGA, AM
    IRABIEN, A
    ORTIZ, MI
    [J]. CHEMICAL ENGINEERING SCIENCE, 1994, 49 (06) : 901 - 909
  • [2] Separation of Cr(VI) with Aliquat 336: Chemical equilibrium modeling
    Alonso, AI
    Galan, B
    Irabien, A
    Ortiz, I
    [J]. SEPARATION SCIENCE AND TECHNOLOGY, 1997, 32 (09) : 1543 - 1555
  • [3] Lipoxygenase-1 mass-transfer coefficient in aqueous two-phase system using spray extraction column
    Arsalani, V
    Rostami, K
    Kheirolomoom, A
    [J]. INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2005, 44 (19) : 7469 - 7473
  • [4] Baird M.I., 1975, CHEM ENG J, V9, P171, DOI [DOI 10.1016/0300-9467(75)80010-4, 10.1016/0300-9467(75)80010-4]
  • [5] BARSON N, 1953, CHEM ENG PROG, V49, P243
  • [6] ELGIN JC, 1934, T AMICHE, V31, P639
  • [7] FLEMING JF, 1953, CHEM ENG PROG, V49, P497
  • [8] MASS TRANSFER COEFFICIENTS IN AN EXTRACTION SPRAY TOWER
    GEANKOPLIS, CJ
    HIXSON, AN
    [J]. INDUSTRIAL AND ENGINEERING CHEMISTRY, 1950, 42 (06): : 1141 - 1151
  • [9] AXIAL-DISPERSION COEFFICIENTS OF THE CONTINUOUS PHASE IN LIQUID-LIQUID SPRAY TOWERS
    GEANKOPLIS, CJ
    SAPP, JB
    ARNOLD, FC
    MARROQUIN, G
    [J]. INDUSTRIAL & ENGINEERING CHEMISTRY FUNDAMENTALS, 1982, 21 (03): : 306 - 311
  • [10] LIQUID-LIQUID SPRAY COLUMN DROP SIZE HOLDUP AND CONTINUOUS PHASE MASS TRANSFER
    HUGHMARK, GA
    [J]. INDUSTRIAL & ENGINEERING CHEMISTRY FUNDAMENTALS, 1967, 6 (03): : 408 - &