Influence of inter-electrode distance on EMG

被引:4
作者
Melaku, A [1 ]
Kumar, DK [1 ]
Bradley, A [1 ]
机构
[1] RMIT UNiv, Sch Elect & Comp Syst Engn, Melbourne, Vic 3000, Australia
来源
PROCEEDINGS OF THE 23RD ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4: BUILDING NEW BRIDGES AT THE FRONTIERS OF ENGINEERING AND MEDICINE | 2001年 / 23卷
关键词
inter-electrode distance; RMS; Time-Frequency;
D O I
10.1109/IEMBS.2001.1020377
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
This paper reports experimental research undertaken to study the effect of variation of inter-electrode distance on the Electromyogram (EMG). The experiments were conducted on ten healthy subjects and they performed isometric contraction of their biceps of the right arm at 20, 50 and 80% of their maximal voluntary contraction (MVC). EMG was recorded using surface electrodes with the distance between the two active electrodes being 18 and 36mm. It has been observed that at low levels of muscle contraction there was no significant variation due to the change in the distance between the electrodes while at 50 and 80% of MVC there was a significant change in the amplitude of the EMG. Using Time- Frequency analysis of EMG, the study demonstrates a variation of the spectral content of the EMG with change in the IED. The study also has shown that there is a variation of the EMG with muscle contraction but that the comparison should be done if the distance between the electrodes has been kept constant.
引用
收藏
页码:1082 / 1085
页数:4
相关论文
共 16 条
[1]  
CLANCY EA, 1995, T BIOMED ENG, V42
[2]  
DELUCA CJ, CRC CRITICAL REV BIO, pV11
[3]  
FARY KA, 1995, IEEE T ROBOTICS
[4]   DETECTION OF MOTOR UNIT ACTION-POTENTIALS WITH SURFACE ELECTRODES - INFLUENCE OF ELECTRODE SIZE AND SPACING [J].
FUGLEVAND, AJ ;
WINTER, DA ;
PATLA, AE ;
STASHUK, D .
BIOLOGICAL CYBERNETICS, 1992, 67 (02) :143-153
[5]  
FUGLEVAND AJ, 1989, MED BIOL SOC 11 ANN
[6]  
GERDLE B, 1990, Electromyography and Clinical Neurophysiology, V30, P483
[7]  
GUPTA V, 1996, HLTH CARE INFORMATIO
[8]  
HERMANS V, EURO J APPL PHYSIO O
[9]   Variability of some SEMG parameter estimates with electrode location [J].
Hogrel, JY ;
Duchene, J ;
Marini, JF .
JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 1998, 8 (05) :305-315
[10]   Normal human right and left ventricular mass, systolic function, and gender differences by cine magnetic resonance imaging [J].
Lorenz, CH ;
Walker, ES ;
Morgan, VL ;
Klein, SS ;
Graham, TP .
JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 1999, 1 (01) :7-21