Adverse Reactions to Metal on Metal Are Not Exclusive to Large Heads in Total Hip Arthroplasty

被引:20
作者
Lombardi, Adolph V., Jr. [1 ,2 ,3 ]
Berend, Keith R. [1 ,2 ,3 ]
Adams, Joanne B. [1 ]
Satterwhite, Keri L. [1 ]
机构
[1] Joint Implant Surg Inc, New Albany, OH 43054 USA
[2] Ohio State Univ, Wexner Med Ctr, Columbus, OH 43210 USA
[3] Mt Carmel Hlth Syst, New Albany, OH USA
关键词
TERM-FOLLOW-UP; ON-METAL; TISSUE-REACTIONS; REPLACEMENT; DEBRIS; SURVIVORSHIP; ARTICULATION; POLYETHYLENE; DISLOCATION; PREVALENCE;
D O I
10.1007/s11999-015-4539-8
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
There is some suggestion that smaller diameter heads in metal-on-metal total hip arthroplasty (MoM THA) may be less prone to the adverse reactions to metal debris (ARMD) seen with large-diameter heads. We reviewed our population of patients with small head (a parts per thousand currency sign 32 mm) MoM THA to determine (1) the frequency of ARMD; (2) potential risk factors for ARMD in this population; and (3) the etiology of revision and Kaplan-Meier survivorship with revision for all causes. Small-diameter head MoM devices were used in 9% (347 of 3753) of primary THAs during the study period (January 1996 to March 2005). We generally used these implants in younger, more active, higher-demand patients. Three hundred hips (258 patients) had MoM THA using a titanium modular acetabular component with a cobalt-chromium tapered insert and were available for review with minimum 2-year followup (mean, 10 years; range, 2-19 years). Complete followup was available in 86% of hips (300 of 347). Clinical records and radiographs were reviewed to determine the frequency and etiology of revision. Kaplan-Meier survivorship analysis was performed. ARMD frequency was 5% (14 of 300 hips) and represented 70% (14 of 20) of revisions performed. Using multivariate analysis, no variable tested, including height, weight, body mass index, age, cup diameter, cup angle, use of screws, stem diameter, stem type, head diameter, preoperative clinical score, diagnosis, activity level, or sex, was significant as a risk factor for revision. Twenty hips have been revised: two for infection, four for aseptic loosening, and 14 for ARMD. Kaplan-Meier analysis revealed survival free of component revision for all causes was 95% at 10 years (95% confidence interval [CI], 91%-97%), 92% at 15 years (95% CI, 87%-95%), and 72% at 19 years (95% CI, 43%-90%), and survival free of component revision for aseptic causes was 96% at 10 years (95% CI, 92%-98%), 92% at 15 years (95% CI, 88%-95%), and 73% at 19 years (95% CI, 43%-90%). The late onset and devastating nature of metal-related failures is concerning with this small-diameter MoM device. Although the liner is modular, it cannot be exchanged and full acetabular revision is required. Patients with all MoM THA devices should be encouraged to return for clinical and radiographic followup, and clinicians should maintain a low threshold to perform a systematic evaluation. Symptomatic patients should undergo thorough investigation and vigilant observation for ARMD. Level IV, therapeutic study.
引用
收藏
页码:432 / 440
页数:9
相关论文
共 52 条
  • [1] Early failures in large head metal-on-metal total hip arthroplasty
    Althuizen, Martje N. R.
    Hooff, Miranda L. V.
    Erp, Saskia H. M. V. D. Berg-v.
    Limbeek, Jacques V.
    Nijhof, Marc W.
    [J]. HIP INTERNATIONAL, 2012, 22 (06) : 641 - 647
  • [2] TREATMENT OF PRIMARY OSTEOARTHRITIS OF THE HIP - A COMPARISON OF TOTAL JOINT AND SURFACE REPLACEMENT ARTHROPLASTY
    AMSTUTZ, HC
    THOMAS, BJ
    JINNAH, R
    KIM, W
    GROGAN, T
    YALE, C
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1984, 66A (02) : 228 - 241
  • [3] [Anonymous], MET MET TOT CONV H S
  • [4] Long-term follow-up and metal ion trend of patients with metal-on-metal total hip arthroplasty
    Bernstein, Mitchell
    Desy, Nicholas M.
    Petit, Alain
    Zukor, David J.
    Huk, Olga L.
    Antoniou, John
    [J]. INTERNATIONAL ORTHOPAEDICS, 2012, 36 (09) : 1807 - 1812
  • [5] Metal Ion Levels and Functional Results Following Resurfacing Hip Arthroplasty Versus Conventional Small-Diameter Metal-on-Metal Total Hip Arthroplasty, a 3 to 5 year Follow-Up of a Randomized Controlled Trial
    Bisseling, Pepijn
    Smolders, Jose M. H.
    Hol, Annemiek
    van Susante, Job L. C.
    [J]. JOURNAL OF ARTHROPLASTY, 2015, 30 (01) : 61 - 67
  • [6] High incidence of pseudotumour formation after large-diameter metal-on-metal total hip replacement A PROSPECTIVE COHORT STUDY
    Bosker, B. H.
    Ettema, H. B.
    Boomsma, M. F.
    Kollen, B. J.
    Maas, M.
    Verheyen, C. C. P. M.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2012, 94B (06): : 755 - 761
  • [7] Serum cobalt levels after metal-on-metal total hip arthroplasty
    Brodner, W
    Bitzan, P
    Meisinger, V
    Kaider, A
    Gottsauner-Wolf, F
    Kotz, R
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2003, 85A (11) : 2168 - 2173
  • [8] Osteolysis in patients with a metal-on-metal hip arthroplasty
    Carr, Ashley M.
    Desteiger, Richard
    [J]. ANZ JOURNAL OF SURGERY, 2008, 78 (03) : 144 - 147
  • [9] Large versus small femoral heads in metal-on-metal total hip arthroplasty
    Cuckler, JM
    Moore, KD
    Lombardi, AV
    McPherson, E
    Emerson, R
    [J]. JOURNAL OF ARTHROPLASTY, 2004, 19 (08) : 41 - 44
  • [10] Primary Hip Arthroplasty With 28-mm Metasul Articulation
    Dastane, Manish
    Wan, Zhinian
    Deshmane, Prashant
    Long, William T.
    Dorr, Lawrence D.
    [J]. JOURNAL OF ARTHROPLASTY, 2011, 26 (04) : 662 - 664