An exhaustive research and analysis on seismic performance of prefabricated concrete shear wall structure

被引:8
作者
Chen, Shuzhen [1 ]
Poongodi, M. [2 ]
机构
[1] Chongqing Vocat Inst Engn, Chongqing 402260, Peoples R China
[2] Hamad Bin Khalifa Univ, Div Informat & Commun Technol, Doha, Qatar
关键词
prefabricated concrete; shear wall structure; seismic performance; ductility; COLUMN; BEHAVIOR; SINGLE; CONSTRUCTION; PANELS; BEAM;
D O I
10.21595/jve.2020.21628
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In order to accelerate the process of building industrialization, improve the overall stability and construction quality of the building. In this paper, a bolted connection method is designed to study the seismic performance of the composite concrete shear wall specimens with horizontal split joints from the aspects of bearing capacity, ductility, energy dissipation, deformation capacity and failure mode. The test results show that the bolted concrete shear wall is feasible and the connectors can effectively connect the upper and lower precast shear walls to form a whole with certain lateral stiffness. The energy dissipation capacity of the specimens is similar to that of other prefabricated concrete shear wall structures with "self-reduction". The displacement Angle is greater than 1/120 of the limit value of the displacement Angle between elastic-plastic layers under the action of large earthquakes, and the specimen has good deformation capacity. The energy dissipation capacity of the structure from dynamics perspective reveals that smaller capacity of the specimen by providing energy dissipation factor E = 0.24 and equivalent viscous damping coefficient of 0.038.
引用
收藏
页码:1871 / 1883
页数:13
相关论文
共 41 条
[1]   Behavior of cold-formed steel wall panels under monotonic horizontal loading [J].
Baran, Eray ;
Alica, Cagatay .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2012, 79 :1-8
[2]  
Belleri A, 2012, PCI J, P97
[3]   A Numerical Investigation on the Performance of the Brick Stair Wall as a Supporting Structure by Considering Adjacent Building [J].
Beyzaei, Mahsa ;
Hosseininia, Ehsan Seyedi .
KSCE JOURNAL OF CIVIL ENGINEERING, 2019, 23 (04) :1513-1521
[4]   Performance Modeling and Analysis of WOM Optical Networks under Wavelength Continuity Constraint using MILP [J].
Bhalaik, Swati ;
Sharma, Ashutosh ;
Kumar, Rajiv ;
Sharma, Neeru .
RECENT ADVANCES IN ELECTRICAL & ELECTRONIC ENGINEERING, 2020, 13 (02) :203-211
[5]   Development and testing of precast concrete beam-to-column connections [J].
Choi, H. -K. ;
Choi, Y. -C. ;
Choi, C. -S. .
ENGINEERING STRUCTURES, 2013, 56 :1820-1835
[6]   Research on the Influence of Guide Blade Trailing Edge Structure on Turbine Performance [J].
Gao Wenjing ;
Li Lei ;
Yue Zhufeng ;
Li Honglin ;
Xie Gongnan ;
Tong Fujuan .
JOURNAL OF THERMAL SCIENCE, 2019, 28 (03) :472-483
[7]   Experimental study and parameter analysis on the seismic performance of self-centering hybrid reinforced concrete shear walls [J].
Gu, Anqi ;
Zhou, Ying ;
Xiao, Yi ;
Li, Qingwu ;
Qu, Ge .
SOIL DYNAMICS AND EARTHQUAKE ENGINEERING, 2019, 116 :409-420
[8]  
Gulkan P., 1998, CEYHAN MISIS EARTHQU
[9]   Effect of axial compression ratio on concrete-filled steel tube composite shear wall [J].
Hou, Hetao ;
Fu, Weiqi ;
Qiu, Canxing ;
Cheng, Jirun ;
Qu, Zhe ;
Zhu, Wencan ;
Ma, Tianxiang .
ADVANCES IN STRUCTURAL ENGINEERING, 2019, 22 (03) :656-669
[10]   Experimental investigation of precast concrete based dry mechanical column-column joints for precast concrete frames [J].
Hu, Ju-Yun ;
Hong, Won-Kee ;
Park, Seon-Chee .
STRUCTURAL DESIGN OF TALL AND SPECIAL BUILDINGS, 2017, 26 (05)