Design of the EXCYT radioactive ion beam separator

被引:11
作者
Ciavola, G [1 ]
Rifuggiato, D [1 ]
Weick, H [1 ]
Winkler, M [1 ]
Wollnik, H [1 ]
机构
[1] UNIV GIESSEN,INST PHYS 2,D-35392 GIESSEN,GERMANY
关键词
D O I
10.1016/S0168-583X(97)01064-1
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The design of a mass separator is described for the radioactive ion beam facility at the INFN-LNS in Catania. The two stages of this separator achieve an energy achromatic mass separation, that should allow one to separate the different elements within one isobar as long as their Q(beta)-values are larger than 5 MeV in the case of nuclei of mass 100. The system also incorporates a preseparator that should retain most of the activity produced in the target and ion source.
引用
收藏
页码:17 / 21
页数:5
相关论文
共 17 条
[1]   The ISOL exotic beam facility at LNS: The EXCYT project [J].
Ciavola, G ;
Calabretta, L ;
Cuttone, G ;
DiBartolo, G ;
Finocchiaro, P ;
Gammino, S ;
Gu, M ;
Migneco, E ;
Qin, J ;
Raia, G ;
Rifuggiato, D ;
Rovelli, A ;
Vinciguerra, D ;
Wollnik, H .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1997, 126 (1-4) :258-261
[2]  
FUJIOKA M, 1989, RAD ION BEAMS, P589
[3]   THE OPTICS OF ISOLDE-3 - THE NEW ONLINE MASS SEPARATOR AT CERN [J].
GEISSE, C ;
WOLLNIK, H ;
ALLARDYCE, B ;
KUGLER, E ;
SCHLOESSER, K .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1987, 26 (1-3) :120-124
[4]  
KUBONO S, 1994, 1N2P3RIKEN
[5]  
QUAMHIEH ZN, 1992, NUCL INSTRUM METH B, V70, P131
[6]  
SUNAOSHI H, 1992, NUCL INSTRUM METH B, V70, P421, DOI 10.1016/0168-583X(92)95959-U
[7]   ION-SOURCE WITH COMBINED CATHODE AND TRANSFER LINE HEATING [J].
SUNDELL, S ;
RAVN, H .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1992, 70 (1-4) :160-164
[8]   ONLINE ISOTOPE SEPARATORS FOR RADIOACTIVE ION-BEAM FACILITIES [J].
WOLLNIK, H .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1995, 363 (1-2) :393-396
[9]   SPECIAL ION DETECTORS WHICH REDUCE THE CONTAMINATION IN ELECTROMAGNETIC ISOTOPE SEPARATORS OR SPECTROMETERS [J].
WOLLNIK, H .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1979, 30 (02) :137-154
[10]   NONLINEAR OPTICAL EFFECTS INDUCED IN ION-BEAMS DURING TRANSPORT [J].
WOLLNIK, H .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1991, 56-7 :1096-1098