The effect of bone porosity on the shear strength of the bone-cement interface

被引:9
|
作者
Amirfeyz, Rouin [1 ]
Bannister, Gordon [1 ]
机构
[1] Southmead Hosp, Bristol Implant Res Ctr, Avon Orthopaed Ctr, Bristol BS10 5NB, Avon, England
关键词
LOW-FRICTION ARTHROPLASTY; HIP; REPLACEMENT; SOCKET;
D O I
10.1007/s00264-008-0558-3
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
This study investigated the relationship of bone porosity and bone-cement interface shear strength. One hundred forty-six samples were taken from the distal metaphysis of 20 bovine femora. After cementation, the shear strength of the bone-cement interface was tested. According to the porosity, the samples were divided into four groups. Group I (porosity < 80%) had a median interface shear strength of 4.03 MPa, group II (80% a parts per thousand currency signporosity < 85%) 7.06 MPa, group III (85% a parts per thousand currency signporosity < 90%) 9.44 MPa, and group IV (porosity a parts per thousand yen90%) 14.85 MPa. The differences between the four groups were statistically significant. Greater porosity yielded a stronger bone-cement interface shear strength under the identical cementation technique. The optimum porosity of cancellous bone is more than 90% which can be found by reaming or drilling to deeper bone in cemented acetabular fixation.
引用
收藏
页码:843 / 846
页数:4
相关论文
共 50 条
  • [1] The effect of bone porosity on the shear strength of the bone–cement interface
    Rouin Amirfeyz
    Gordon Bannister
    International Orthopaedics, 2009, 33 : 843 - 846
  • [2] Effect of bone porosity on the mechanical integrity of the bone-cement interface
    Graham, J
    Ries, M
    Pruitt, L
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2003, 85A (10): : 1901 - 1908
  • [3] Effect of cement modulus on the shear properties of the bone-cement interface
    Orthopaedic BioMaterials Laboratory, S-2035 Davis Center, 480 West Ninth Avenue, Columbus, OH 43210-1128, United States
    Biomaterials, 17 (1561-1567):
  • [4] Effect of cement modulus on the shear properties of the bone-cement interface
    Funk, MJ
    Litsky, AS
    BIOMATERIALS, 1998, 19 (17) : 1561 - 1567
  • [5] THE EFFECT OF POLYMETHYLMETHACRYLATE BONE-CEMENT VIBRATION ON THE BONE-CEMENT INTERFACE
    THOMAS, AMC
    MCMINN, DJW
    HADDAWAY, M
    MCCALL, IW
    CELLS AND MATERIALS, 1992, 2 (02): : 163 - 168
  • [6] EFFECT OF GENTAMICIN ON SHEAR AND INTERFACE STRENGTHS OF BONE-CEMENT
    MORAN, JM
    GREENWALD, AS
    MATEJCZYK, MB
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1979, (141) : 96 - 101
  • [7] INFLUENCE OF REVISION ARTHROPLASTY ON BONE-CEMENT INTERFACE SHEAR-STRENGTH
    BECHTOLD, JE
    DOHMAE, Y
    SHERMAN, RE
    GUSTILO, RB
    JOURNAL OF BIOMECHANICS, 1987, 20 (08) : 824 - 824
  • [8] The eburnated bone-cement interface
    Kamat, Yogeesh D.
    Crocombe, Andrew
    Bradley, William Neil
    CURRENT ORTHOPAEDIC PRACTICE, 2014, 25 (05): : 484 - 487
  • [9] POROSITY IN MANUALLY MIXED BONE-CEMENT
    LINDEN, U
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1988, (231) : 110 - 112
  • [10] EFFECT OF AN INVIVO ENVIRONMENT ON THE STRENGTH OF BONE-CEMENT
    ROSTOKER, W
    LEREIM, P
    GALANTE, JO
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1979, 13 (03): : 365 - 370