Experimental investigation on a hybrid desalination and cooling unit using humidification-dehumidification technique

被引:9
作者
Chiranjeevi, C. [1 ]
Srinivas, T. [2 ]
Shankar, R. [1 ]
机构
[1] VIT, SMEC, Dept Thermal & Energy Engn, Vellore, Tamil Nadu, India
[2] Dr BR Ambedkar Natl Inst Technol Jalandhar, Dept Mech Engn, Jalandhar, Punjab, India
关键词
Humidification; Dehumidification; Desalination; Cooling; Hybrid systems; Fresh water; ENERGY RECOVERY; SOLAR AIR; SYSTEM; HDH; WATER; PERFORMANCE;
D O I
10.5004/dwt.2019.23680
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Rapid growth in urbanization, industrialization and decrease in rainfall rates all over the world demands more fresh water for human use, industries and agriculture purpose. The novel desalination technologies for converting saline water into fresh water have more value and demand. Present work aim at evaluating the performance of an integrated air cooling and two stage desalination system using humidification dehumidification (HDH) technology experimentally by varying flow rate and temperature of saline water. The components of the proposed system are designed, developed and carried out experiments for different operating conditions to get optimum operating conditions. The plant consists of a solar water heater (SWH), two air preheaters, two humidifiers, two dehumidifiers with a normal and a vapour compression refrigeration water chiller. The influence of saline water temperature and flow rate on air temperature, desalination yield, recovery ratio, energy utilization factor (EUF), air cooling effect and coefficient of performance (COP) of the cooling system are studied. The experimental observations recommend higher saline water temperature with high flow rates to air preheaters and humidifiers, circulating and chilled water to dehumidifiers with lower possible temperatures. The integrated plant yields 240 W of cooling energy and a maximum fresh water of 2180 ml/h with 15 m(3)/h air flow at saline water temperature of 54.5 degrees C with a flow rate of 200 LPH. Experimental results show a maximum EUF of 0.5 for the hybrid plant and 0.45 for conventional plant single stage plant. A maximum COP of 2.2 with a recovery ratio of 0.78 is observed from the experimental results.
引用
收藏
页码:148 / 160
页数:13
相关论文
共 39 条
[1]   EXPERIMENTAL-STUDY OF HUMIDIFICATION-DEHUMIDIFICATION DESALINATION SYSTEM [J].
ABDELSALAM, MS ;
HILAL, MM ;
ELDIB, AF ;
ABDELMONEM, M .
ENERGY SOURCES, 1993, 15 (03) :475-490
[2]   Experimental investigation of humidification-dehumidification desalination system with corrugated packing in the humidifier [J].
Ahmed, Hossam A. ;
Ismail, I. M. ;
Saleh, Wael F. ;
Ahmed, M. .
DESALINATION, 2017, 410 :19-29
[3]   Theoretical and experimental investigation of humidification-dehumidification desalination unit [J].
Amer, E. H. ;
Kotb, H. ;
Mostafa, G. H. ;
El-Ghalban, A. R. .
DESALINATION, 2009, 249 (03) :949-959
[4]  
Anand B., 2017, Applied Solar Energy, V53, P243, DOI [10.3103/S0003701X17030045, 10.3103/s0003701x17030045]
[5]   Experimental investigations on the performance of an air heated humidification-dehumidification desalination system [J].
Antar, Mohamed A. ;
Sharqawy, Mostafa H. .
DESALINATION AND WATER TREATMENT, 2013, 51 (4-6) :837-843
[6]   Augmented desalination with cooling integration [J].
Chiranjeevi, C. ;
Srinivas, T. .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2017, 80 :106-119
[7]   Influence of vapor absorption cooling on humidification-dehumidification (HDH) desalination [J].
Chiranjeevi, C. ;
Srinivas, T. .
ALEXANDRIA ENGINEERING JOURNAL, 2016, 55 (03) :1961-1967
[8]   Experimental and simulation studies on two stage humidification-dehumidification desalination and cooling plant [J].
Chiranjeevi, C. ;
Srinivas, T. .
DESALINATION, 2015, 376 :9-16
[9]   Combined two stage desalination and cooling plant [J].
Chiranjeevi, C. ;
Srinivas, T. .
DESALINATION, 2014, 345 :56-63
[10]   Experimental investigation of a solar desalination unit with humidification and dehumidification [J].
Dai, YJ ;
Zhang, HF .
DESALINATION, 2000, 130 (02) :169-175