Changes in Aortic Volumes Following Endovascular Sealing of Abdominal Aortic Aneurysms With the Nellix Endoprosthesis

被引:14
作者
Shaikh, Usman [1 ]
Chan, Tze Y. [2 ]
Oshin, Olufemi [1 ]
McWilliams, Richard G. [1 ]
Fisher, Robert K. [1 ]
England, Andrew [3 ]
Torella, Francesco [1 ]
机构
[1] Royal Liverpool Univ Hosp, Liverpool Vasc & Endovasc Serv, Liverpool L7 8XP, Merseyside, England
[2] Royal Liverpool Univ Hosp, Dept Intervent Radiol, Liverpool L7 8XP, Merseyside, England
[3] Univ Salford, Dept Radiog, Salford M5 4WT, Lancs, England
基金
美国国家卫生研究院;
关键词
abdominal aortic aneurysm; aortic lumen; computed tomography; endovascular aneurysm sealing; thrombus; volume change; SYSTEM;
D O I
10.1177/1526602815607186
中图分类号
R61 [外科手术学];
学科分类号
摘要
Purpose: To investigate the effects on aortic volumes of endovascular aneurysm sealing (EVAS) with the Nellix device. Methods: Twenty-five consecutive patients (mean age 78 +/- 7 years; 17 men) with abdominal aortic aneurysms containing thrombus were treated with EVAS. Their pre- and post-EVAS computed tomography (CT) scans were reviewed to document volume changes in the entire aneurysmal aorta, the lumen, and the intraluminal thrombus. The changes are reported as the mean and 95% confidence interval (CI). Results: Total aortic volume was greater on postoperative scans by a mean 17 mL (95% CI 10.0 to 23.5, p<0.001). The volume occupied by the endobags was greater than the preoperative lumen volume by a mean 28 mL (95% CI 24.7 to 31.7, p=0.002). Postoperatively, the aortic volume occupied by thrombus had decreased by a mean 11 mL (95% CI 4.7 to 18.2, p<0.001). There were good correlations between changes in aneurysm and thrombus volumes (r=0.864, p<0.001), between the planning CT/EVAS time interval and the change in aneurysm volume (r=0.640, p=0.001), and between the planning CT/EVAS time interval and the change in thrombus volume (r=0.567, p=0.003). Conclusion: There are significant changes in aortic volumes post EVAS. These changes may be a direct consequence of the technique and have implications for the planning and performance of EVAS.
引用
收藏
页码:881 / 885
页数:5
相关论文
共 8 条
[1]   Multicenter Nellix EndoVascular Aneurysm Sealing system experience in aneurysm sac sealing [J].
Boeckler, Dittmar ;
Holden, Andrew ;
Thompson, Matt ;
Hayes, Paul ;
Krievins, Dainis ;
de Vries, Jean-Paul P. M. ;
Reijnen, Michel M. P. J. .
JOURNAL OF VASCULAR SURGERY, 2015, 62 (02) :290-298
[2]   Initial clinical experience with a sac-anchoring endoprosthesis for aortic aneurysm repair [J].
Donayre, Carlos E. ;
Zarins, Christopher K. ;
Krievins, Dainis K. ;
Holden, Andrew ;
Hill, Andrew ;
Calderas, Carlos ;
Velez, Jaime ;
White, Rodney A. .
JOURNAL OF VASCULAR SURGERY, 2011, 53 (03) :574-582
[3]  
Endologix, 2013, NELL INSTR US
[4]   Use of cine magnetic resonance angiography in quantifying aneurysm pulsatility associated with endoleak [J].
Faries, PL ;
Agarwal, G ;
Lookstein, R ;
Bernheim, JW ;
Cayne, NS ;
Cadot, H ;
Goldman, J ;
Kent, KC ;
Hollier, LH ;
Marin, NL .
JOURNAL OF VASCULAR SURGERY, 2003, 38 (04) :652-656
[5]   EVAR Using the Nellix Sac-anchoring Endoprosthesis: Treatment of Favourable and Adverse Anatomy [J].
Krievins, D. K. ;
Holden, A. ;
Savlovskis, J. ;
Calderas, C. ;
Donayre, C. E. ;
Moll, F. L. ;
Katzen, B. ;
Zarins, C. K. .
EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2011, 42 (01) :38-46
[6]   Observations on Surveillance Imaging After Endovascular Sealing of Abdominal Aortic Aneurysms With the Nellix System [J].
McWilliams, Richard G. ;
Fisher, Robert K. ;
England, Andrew ;
Torella, Francesco .
JOURNAL OF ENDOVASCULAR THERAPY, 2015, 22 (03) :303-306
[7]   In-Vivo Imaging of Changes in Abdominal Aortic Aneurysm Thrombus Volume During the Cardiac Cycle [J].
Truijers, Maarten ;
Fillinger, Mark F. ;
Renema, KlaasJan W. ;
Marra, Steven P. ;
Oostveen, Luuk J. ;
Kurvers, Harrie A. J. M. ;
SchultzeKool, Leo J. ;
Blankensteijn, Jan D. .
JOURNAL OF ENDOVASCULAR THERAPY, 2009, 16 (03) :314-319
[8]   Intra- and Interobserver Variability of Aortic Aneurysm Volume Measurement With Fast CTA Postprocessing Software [J].
van Prehn, Joffrey ;
van der Wal, Martijn B. A. ;
Vincken, Koen ;
Bartels, Lambertus W. ;
Moll, Frans L. ;
van Herwaarden, Joost A. .
JOURNAL OF ENDOVASCULAR THERAPY, 2008, 15 (05) :504-510