Continuous Glucose Monitoring During Basal-Bolus Therapy Using Insulin Glargine 300 U mL-1 and Glargine 100 U mL-1 in Japanese People with Type 1 Diabetes Mellitus: A Crossover Pilot Study

被引:21
作者
Jinnouchi, Hideaki [1 ]
Koyama, Masayoshi [2 ]
Amano, Atsushi [2 ]
Takahashi, Yoshinori [2 ]
Yoshida, Akira [1 ]
Hieshima, Kunio [1 ]
Sugiyama, Seigo [1 ]
Kurinami, Noboru [1 ]
Jinnouchi, Tomio [1 ]
Becker, Reinhard [3 ]
机构
[1] Jinnouchi Hosp, Kumamoto, Japan
[2] Sanofi, Tokyo, Japan
[3] Sanofi Aventis Deutschland GmbH, Diabet Div, D-65929 Frankfurt, Germany
关键词
Continuous glucose monitoring; Hypoglycemia; Insulin glargine; Type; 1; diabetes; GLYCEMIC CONTROL; HYPOGLYCEMIA; U/ML; PROVIDES; UNITS/ML;
D O I
10.1007/s13300-015-0115-1
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: New insulin glargine 300 U mL(-1) (Gla-300) is a basal insulin that shows more stable and prolonged pharmacokinetic and pharmacodynamic profiles than insulin glargine 100 U mL(-1) (Gla-100). This study used continuous glucose monitoring (CGM) to compare 24-h glucose profiles in a Japanese population using Gla-300 versus Gla-100. Methods: This was an exploratory 8.4-week, single-center, 2-sequence, 2-period, open-label crossover study. Japanese adults with type 1 diabetes mellitus (T1DM) treated with basal-bolus insulin, with glycated hemoglobin HbA1c) 6.5-10.0% and median fasting self-monitored plasma glucose concentration <= 13 mmol L-1, were randomized to Gla-300 followed by Gla-100 (subgroup 1) or vice versa (subgroup 2), with no washout period. CGM was performed on the last 3 days of the screening period and each treatment period. Primary endpoint was comparison of 24-h glucose variability (area under the curve [AUC](mean_24 h)) on the second day of each CGM measurement with Gla-300 versus Gla-100. Baseline and end of treatment period values for HbA1c, fasting plasma glucose (FPG) and daily basal/mealtime insulin doses were recorded. Hypoglycemia and adverse events (AEs) were recorded. Results: Twenty participants were randomized (10 to subgroup 1 and 10 to subgroup 2). Participants showed comparable glucose variability over 24 h (AUC(mean_24 h) during treatment with Gla-300 or Gla-100 (treatment ratio 0.96; 90% confidence interval 0.79, 1.16). HbA1c and FPG were generally stable across both treatment periods. There was a trend towards fewer participants experiencing >= 1 hypoglycemia event at any time (24 h) and at night (00: 00-05: 59 h) with Gla-300 versus Gla-100. Treatment-emergent AEs, reported by 9/20 (45%) and 4/20 (20%) participants during Gla-300 and Gla-100 treatment, respectively, wereunrelated to study medication. Conclusions: In this cohort of Japanese people with T1DM, no between-treatment difference was observed in glucose variability with Gla-300 versus Gla-100, as measured by CGM. There was a trend for less hypoglycemia with Gla-300, particularly at night, versus Gla-100. Both treatments were well tolerated.
引用
收藏
页码:143 / 152
页数:10
相关论文
共 50 条
  • [31] Switching the basal insulin to insulin glargine 300 U/ml in people with type 2 diabetes under basal insulin supported oral therapy: Observational trial on effectiveness and safety
    Seufert, Jochen
    Wiesli, Peter
    Fritsche, Andreas
    Anderten, Helmut
    Pegelow, Katrin
    Pscherer, Stefan
    Pfohl, Martin
    DIABETES OBESITY & METABOLISM, 2022, 24 (01) : 72 - 81
  • [32] Sustained glycaemic control and less nocturnal hypoglycaemia with insulin glargine 300 U/mL compared with glargine 100 U/mL in Japanese adults with type 1 diabetes (EDITION JP 1 randomised 12-month trial including 6-month extension)
    Matsuhisa, Munehide
    Koyama, Masayoshi
    Cheng, Xi
    Sumi, Mariko
    Riddle, Matthew C.
    Bolli, Geremia B.
    Hirose, Takahisa
    DIABETES RESEARCH AND CLINICAL PRACTICE, 2016, 122 : 133 - 140
  • [33] Glycaemic control and hypoglycaemia in people with type 2 diabetes switching from twice-daily basal insulin to once-daily insulin glargine 300 U/mL or insulin glargine 100 U/mL (EDITION 1 and EDITION 2 subgroup analysis)
    Roussel, Ronan
    d'Emden, Michael C.
    Fisher, Miles
    Javier Ampudia-Blasco, F.
    Stella, Peter
    Bizet, Florence
    Cali, Anna M. G.
    Wysham, Carol H.
    DIABETES OBESITY & METABOLISM, 2018, 20 (02) : 448 - 452
  • [34] Effectiveness of insulin glargine U-300 versus insulin glargine U-100 on nocturnal hypoglycemia and glycemic control in type 1 and type 2 diabetes: a systematic review and meta-analysis
    Diez-Fernandez, Ana
    Cavero-Redondo, Ivan
    Moreno-Fernandez, Jesus
    Pozuelo-Carrascosa, Diana P.
    Garrido-Miguel, Miriam
    Martinez-Vizcaino, Vicente
    ACTA DIABETOLOGICA, 2019, 56 (03) : 355 - 364
  • [35] Effect of switching from twice-daily basal insulin to once-daily insulin glargine 300 U/mL (Gla-300) in Brazilian people with type 1 diabetes
    Dualib, Patricia Medici
    Dib, Sergio Atala
    Augusto, Gustavo Akerman
    Truzzi, Ana Cristina
    de Paula, Mauricio Aguiar
    Rea, Rosangela Roginski
    DIABETOLOGY & METABOLIC SYNDROME, 2024, 16 (01)
  • [36] Comparison of Insulin Glargine 300 U/mL and Insulin Degludec 100 U/mL Around Spontaneous Exercise Sessions in Adults with Type 1 Diabetes: A Randomized Cross-Over Trial (ULTRAFLEXI-1 Study)
    Moser, Othmar
    Mueller, Alexander
    Aberer, Felix
    Aziz, Faisal
    Kojzar, Harald
    Sourij, Caren
    Obermayer, Anna
    Abbas, Farah
    Birnbaumer, Philipp
    Lenz, Jacqueline
    Mursic, Ines
    Sternad, Christoph
    Hoenger, Lukas
    Ziko, Haris
    Pferschy, Peter N.
    Tripolt, Norbert
    Sourij, Harald
    DIABETES TECHNOLOGY & THERAPEUTICS, 2023, 25 (03) : 161 - 168
  • [37] Effectiveness and Safety of Insulin Glargine 300 U/ml in Comparison with Insulin Degludec 100 U/ml Evaluated with Continuous Glucose Monitoring in Adults with Type 1 Diabetes and Suboptimal Glycemic Control in Routine Clinical Practice: The OneCARE Study
    Conget, Ignacio
    Angel Mangas, Miguel
    Morales, Cristobal
    Caro, Juan
    Gimenez, Margarita
    Borrell, Mireia
    Delgado, Elias
    DIABETES THERAPY, 2021, 12 (11) : 2993 - 3009
  • [38] Efficacy and safety of switching to insulin glargine 300 U/mL in people with type 2 diabetes uncontrolled on basal insulin in China: A post hoc subpopulation analysis of the INITIATION study
    Chen, Liming
    Wan, Hailong
    Han, Jie
    Yang, Caixian
    Shao, Hailin
    Li, Jialin
    Yan, Wensheng
    Xiao, Jianzhong
    Sun, Yadong
    Li, Min
    Han, Yanfang
    Kang, Lei
    Zhang, Minlu
    DIABETES OBESITY & METABOLISM, 2025, 27 (03) : 1423 - 1431
  • [39] Patient-Reported Outcomes with Insulin Glargine 300 U/mL in People with Type 2 Diabetes: The MAGE Multicenter Observational Study
    Colin, Ides M.
    Alexandre, Kathy
    Bruhwyler, Jacques
    Scheen, Andre
    Verhaegen, Ann
    DIABETES THERAPY, 2020, 11 (08) : 1835 - 1847
  • [40] Experience after switching from insulin glargine U100 to glargine U300 in patients with type 1 diabetes mellitus. A study after one year of treatment in real life
    Pujante Alarcon, Pedro
    Rodriguez Escobedo, Raul
    Garcia Urruzola, Fernando
    Ares, Jessica
    Manjon, Laura
    Sanchez Ragnarson, Cecilia
    Cacho, Laura
    Delgado, Elias
    Menendez Torre, Edelmiro L.
    ENDOCRINOLOGIA DIABETES Y NUTRICION, 2019, 66 (04): : 210 - 216