Diagnostic Accuracy of Low and Ultra-Low Dose CT for Identification of Urinary Tract Stones: A Systematic Review

被引:70
作者
Rodger, Flora [1 ]
Roditi, Giles [1 ]
Aboumarzouk, Omar M. [1 ]
机构
[1] Queen Elizabeth Univ Hosp, NHS Greater Glasgow & Clyde, 1345 Govan Rd, Glasgow G51 4TF, Lanark, Scotland
关键词
Stones; Computed tomography; Urolithiasis; Non-contrasted computed tomography scan of the kidney; ureter; and bladder Radiation safety; Renal colic; STATISTICAL ITERATIVE RECONSTRUCTION; UROLITHIASIS IMAGE QUALITY; NON-CONTRAST CT; COMPUTED-TOMOGRAPHY; MULTIDETECTOR CT; RADIATION; STANDARD; PERFORMANCE; CALCULI; IMPACT;
D O I
10.1159/000488062
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Background: Non-contrast computed tomography of the kidneys, ureters, and bladder (CT KUB) is the investigation of choice for renal colic; however, radiation exposure can be a concern. Aims: The study aimed to investigate the diagnostic accuracy of low dose (LD) and ultra-low dose (ULD) CT of the urinary tract for detection of urinary tract stones in patients with renal colic. Methods: A Cochrane style systematic review of the literature from 1995 to 2017 was carried out. Literature search and data extraction were conducted by 2 reviewers. Specificity and sensitivity values were calculated for LD (< 3.5 mean radiation dose [mSv]) and ULD (< 1.9 mSv) CT separately. Results: A total of 12 studies were included following screening. A total of 1,529 patients were included in the review (475 in the LD group and 1,054 in the ULD group). Using standard dose CT KUB as the reference standard, the sensitivity of LD CT KUB ranged from 90 to 98% and specificity from 88 to 100%. The sensitivity of ULD CT KUB ranged from 72 to 99% and the specificity ranged from 86 to 100%. The diagnostic accuracy for LD CT was 94.3% and for ULD CT was 95.5%. Conclusions: LD and ULD CT KUB provide effective methods of identifying urinary tract stones. High diagnostic accuracy, sensitivity, and specificity are maintained despite significant radiation dose reduction in comparison to standard dose CT. (C) 2018 S. Karger AG, Basel
引用
收藏
页码:375 / 385
页数:11
相关论文
共 50 条
  • [21] Low-dose CT of paediatric paranasal sinus using an ultra-low tube voltage (70 kVp) combined with the flash technique
    Chi, J.
    Ji, Y-D
    Shen, L.
    Yin, S-N
    Ding, N.
    Chen, X-F
    Xu, D-F
    CLINICAL RADIOLOGY, 2021, 76 (01) : 77.e17 - 77.e21
  • [22] Use of ultra-low contrast dose CT aortography for the management of aortic aneurysmal disease
    Borkowski, Philip
    Ng, Eugene
    Vicaretti, Mauro
    Young, Noel
    JOURNAL OF CARDIOTHORACIC SURGERY, 2024, 19 (01)
  • [23] Feasibility of spectral shaping for detection and quantification of coronary calcifications in ultra-low dose CT
    Vonder, Marleen
    Pelgrim, Gert Jan
    Huijsse, Sevrin E. M.
    Meyer, Mathias
    Greuter, Marcel J. W.
    Henzler, Thomas
    Flohr, Thomas G.
    Oudkerk, Matthijs
    Vliegenthart, Rozemarijn
    EUROPEAN RADIOLOGY, 2017, 27 (05) : 2047 - 2054
  • [24] Ultra-low-dose, low-dose, and standard-dose CT of the kidney, ureters, and bladder: is there a difference? Results from a systematic review of the literature
    Rob, S.
    Bryant, T.
    Wilson, I.
    Somani, B. K.
    CLINICAL RADIOLOGY, 2017, 72 (01) : 11 - 15
  • [25] Feasibility of spectral shaping for detection and quantification of coronary calcifications in ultra-low dose CT
    Marleen Vonder
    Gert Jan Pelgrim
    Sèvrin E. M. Huijsse
    Mathias Meyer
    Marcel J. W. Greuter
    Thomas Henzler
    Thomas G. Flohr
    Matthijs Oudkerk
    Rozemarijn Vliegenthart
    European Radiology, 2017, 27 : 2047 - 2054
  • [26] Helical computed tomography of urinary tract stones: Accuracy and diagnostic value of stone size and density measurements
    Dobbins J.M.
    Novelline R.A.
    Rhea J.T.
    Rao P.M.
    Prien E.L. Jr.
    Dretler S.R.
    Emergency Radiology, 1997, 4 (5) : 303 - 308
  • [27] Low-dose CT angiography using ASiR-V for potential living renal donors: a prospective analysis of image quality and diagnostic accuracy
    Han, Woong Kyu
    Na, Joon Chae
    Park, Sung Yoon
    EUROPEAN RADIOLOGY, 2020, 30 (02) : 798 - 805
  • [28] Ultra-low-dose CT to search for stones in kidneys and collecting system
    Rogalla, P
    Klüner, C
    Taupitz, M
    AKTUELLE UROLOGIE, 2004, 35 (04) : 307 - 309
  • [29] Comparison of conventional chest x ray with a novel projection technique for ultra-low dose CT
    Carey, Sean
    Kandel, Sonja
    Farrell, Christin
    Kavanagh, John
    Chung, TaeBong
    Hamilton, William
    Rogalla, Patrik
    MEDICAL PHYSICS, 2021, 48 (06) : 2809 - 2815
  • [30] High-pitch low-dose abdominopelvic CT with tin-filtration technique for detecting urinary stones
    Gu-Mu-Yang Zhang
    Bing Shi
    Hao Sun
    Hua-Dan Xue
    Yun Wang
    Ji-Xiang Liang
    Kai Xu
    Ming Wang
    Man Wang
    Min Xu
    Zheng-Yu Jin
    Abdominal Radiology, 2017, 42 : 2127 - 2134