Diagnostic Accuracy of Low and Ultra-Low Dose CT for Identification of Urinary Tract Stones: A Systematic Review

被引:70
作者
Rodger, Flora [1 ]
Roditi, Giles [1 ]
Aboumarzouk, Omar M. [1 ]
机构
[1] Queen Elizabeth Univ Hosp, NHS Greater Glasgow & Clyde, 1345 Govan Rd, Glasgow G51 4TF, Lanark, Scotland
关键词
Stones; Computed tomography; Urolithiasis; Non-contrasted computed tomography scan of the kidney; ureter; and bladder Radiation safety; Renal colic; STATISTICAL ITERATIVE RECONSTRUCTION; UROLITHIASIS IMAGE QUALITY; NON-CONTRAST CT; COMPUTED-TOMOGRAPHY; MULTIDETECTOR CT; RADIATION; STANDARD; PERFORMANCE; CALCULI; IMPACT;
D O I
10.1159/000488062
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Background: Non-contrast computed tomography of the kidneys, ureters, and bladder (CT KUB) is the investigation of choice for renal colic; however, radiation exposure can be a concern. Aims: The study aimed to investigate the diagnostic accuracy of low dose (LD) and ultra-low dose (ULD) CT of the urinary tract for detection of urinary tract stones in patients with renal colic. Methods: A Cochrane style systematic review of the literature from 1995 to 2017 was carried out. Literature search and data extraction were conducted by 2 reviewers. Specificity and sensitivity values were calculated for LD (< 3.5 mean radiation dose [mSv]) and ULD (< 1.9 mSv) CT separately. Results: A total of 12 studies were included following screening. A total of 1,529 patients were included in the review (475 in the LD group and 1,054 in the ULD group). Using standard dose CT KUB as the reference standard, the sensitivity of LD CT KUB ranged from 90 to 98% and specificity from 88 to 100%. The sensitivity of ULD CT KUB ranged from 72 to 99% and the specificity ranged from 86 to 100%. The diagnostic accuracy for LD CT was 94.3% and for ULD CT was 95.5%. Conclusions: LD and ULD CT KUB provide effective methods of identifying urinary tract stones. High diagnostic accuracy, sensitivity, and specificity are maintained despite significant radiation dose reduction in comparison to standard dose CT. (C) 2018 S. Karger AG, Basel
引用
收藏
页码:375 / 385
页数:11
相关论文
共 50 条
  • [1] Diagnostic accuracy of low-dose and ultra-low-dose CT in detection of chest pathology: a systematic review
    Taekker, Maria
    Kristjansdottir, Bjorg
    Graumann, Ole
    Laursen, Christian B.
    Pietersen, Pia, I
    CLINICAL IMAGING, 2021, 74 : 139 - 148
  • [2] Ultra-low dose CT scanning for PET/CT
    Mostafapour, Samaneh
    Greuter, Marcel
    van Snick, Johannes H.
    Brouwers, Adrienne H.
    Dierckx, Rudi A. J. O.
    van Sluis, Joyce
    Lammertsma, Adriaan A.
    Tsoumpas, Charalampos
    MEDICAL PHYSICS, 2024, 51 (01) : 139 - 155
  • [3] Diagnostic accuracy of ultra-low-dose CT colonography for the detection of colorectal polyps: a feasibility study
    Yasuda, Takaaki
    Honda, Tetsuro
    Utano, Kenichi
    Kato, Takashi
    Togashi, Kazutomo
    Yamaguchi, Shota
    Yasaka, Takahiro
    JAPANESE JOURNAL OF RADIOLOGY, 2022, 40 (08) : 831 - 839
  • [4] Ultra-low dose chest CT: The end of chest radiograph?
    Ludes, Claire
    Schaal, Marysa
    Labani, Aissam
    Jeung, Mi-Young
    Roy, Catherine
    Ohana, Mickael
    PRESSE MEDICALE, 2016, 45 (03): : 291 - 301
  • [5] Detectability of Lung Nodules in Ultra-low Dose CT
    Janssen, Sonja
    Overhoff, Daniel
    Froelich, Matthias F.
    Schoenberg, Stefan O.
    Rathmann, Nils
    ANTICANCER RESEARCH, 2021, 41 (10) : 5053 - 5058
  • [6] In vitro accuracy of ultra-low dose cone-beam CT for detection of proximal caries
    Taeby, Aria
    Seyyedi, Seyyed Amir
    Mostafavi, Maryam
    DENTOMAXILLOFACIAL RADIOLOGY, 2024, 53 (07) : 459 - 467
  • [7] Limits of Ultra-Low Dose CT Attenuation Correction for PET/CT
    Xia, Ting
    Alessio, Adam M.
    Kinahan, Paul E.
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 3074 - 3079
  • [8] Detection of pulmonary nodules: a clinical study protocol to compare ultra-low dose chest CT and standard low-dose CT using ASIR-V
    Ludwig, Marie
    Chipon, Emilie
    Cohen, Julien
    Reymond, Emilie
    Medici, Maud
    Cole, Anthony
    Moreau Gaudry, Alexandre
    Ferretti, Gilbert
    BMJ OPEN, 2019, 9 (08):
  • [9] Seventy kilovolt ultra-low dose CT of the paranasal sinus: first clinical results
    Bodelle, B.
    Wichmann, J. L.
    Klotz, N.
    Lehnert, T.
    Vogl, T. J.
    Luboldt, W.
    Schulz, B.
    CLINICAL RADIOLOGY, 2015, 70 (07) : 711 - 715
  • [10] Ultra-low Dose Lung CT Perfusion Regularized by a Previous Scan
    Yu, Hengyong
    Zhao, Shiying
    Hoffman, Eric A.
    Wang, Ge
    ACADEMIC RADIOLOGY, 2009, 16 (03) : 363 - 373