Research and Application of On-line Monitoring Device for Dry-type Air-core Reactor

被引:0
|
作者
Zhu, Yongcan [1 ]
Xue, Zhipeng [1 ]
Zhou, Yan [1 ]
Hu, Jie [1 ]
Liu, Junjun [1 ]
Li, Zhiwen [1 ]
机构
[1] Xian Polytech Univ, Elect Informat Sch, Xian, Shaanxi, Peoples R China
关键词
Dry-type air-core reactor; Interturn short circuit; power factor angle;
D O I
暂无
中图分类号
TP3 [计算技术、计算机技术];
学科分类号
0812 ;
摘要
Dry-type air-core reactor is a high-voltage equipment used in power system for current limiting, reactive power compensation and filtering, which often fails due to insulation aging in long-term operation, and among them the interturn short circuit fault rate is the highest. In this paper, an on-line monitoring device for dry-type air core reactor based on power angle is proposed. This device can realise data acquisition of multi-channel signals at the same time and achieve high-precision conversion. Finally, the power factor angle is obtained through data processing. The test results show that the device can effectively monitor the short-circuit insulation short-circuit fault of the reactor.
引用
收藏
页数:2
相关论文
共 50 条
  • [1] On-line Monitoring Technology of Inter-turn Short Circuit Fault of Dry-type Air-core Reactor
    Huang X.
    Zhou Y.
    Zhu Y.
    Cao W.
    Zhang L.
    Wu H.
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2019, 43 (02): : 150 - 155and181
  • [3] Study on the Nonlinear Vibration Characteristic of Dry-Type Air-Core Reactor
    Jiang, Zhitong
    Zhu, Lingyu
    Yang, Hang
    Ji, Shengchang
    Xia, Xinqian
    Li, Jinyu
    Cui, Hantao
    2018 IEEE INTERNATIONAL POWER MODULATOR AND HIGH VOLTAGE CONFERENCE (IPMHVC), 2018, : 99 - 104
  • [4] An embedded FBG strain sensor used in the dry-type air-core reactor health monitoring
    Zhou, Yan-Hui
    Zhao, Zhen-Gang
    Li, Ying-Na
    Zhang, Chang-Sheng
    Xie, Tao
    Cui, Zhi-Gang
    Wang, Ke
    Tan, Xiang-Yu
    Li, Chuan
    Guangdianzi Jiguang/Journal of Optoelectronics Laser, 2015, 26 (03): : 422 - 426
  • [5] Calculation of magnetic field and inductance of dry-type air-core reactor
    Liu, Zhi-Gang
    Wang, Jian-Hua
    Geng, Ying-San
    Shi, Cang-Hui
    Gaoya Dianqi/High Voltage Apparatus, 2003, 39 (03):
  • [6] Influence of temperature rise on quality of dry-type air-core reactor
    Ye, Zhangang
    Bianyaqi/Transformer, 35 (03): : 31 - 33
  • [7] Research of the power frequency magnetic fields distribution around Dry-type Air-core Reactor
    Yan, Zhang
    Quandi, Wang
    Bin, Li
    Yi, Zhao
    Liu Qingsheng
    Refai, Hazem H.
    2008 WORLD AUTOMATION CONGRESS PROCEEDINGS, VOLS 1-3, 2008, : 1303 - 1306
  • [8] Research on turn-to-turn insulation test method of dry-type air-core reactor
    Wei, XL
    Cheng, SK
    Wu, J
    Wang, YH
    PROCEEDINGS OF THE 6TH INTERNATIONAL CONFERENCE ON PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, VOLS 1 & 2, 2000, : 1058 - 1061
  • [9] Research on the Modeling Method and Turn-to-turn Short Circuit Monitoring Method for the Dry-type Air-core Reactor
    Qin Risheng
    Wang Wenlin
    Wang Bin
    2018 2ND IEEE CONFERENCE ON ENERGY INTERNET AND ENERGY SYSTEM INTEGRATION (EI2), 2018,
  • [10] Transient Overvoltage Calculation of Dry-type Air-core Reactor with Complex Topology
    Zhu, Dengfeng
    Jin, Liang
    TWENTIETH BIENNIAL IEEE CONFERENCE ON ELECTROMAGNETIC FIELD COMPUTATION (IEEE CEFC 2022), 2022,