A resonant damping control and analysis for LCL-type grid-connected inverter

被引:22
作者
Khan, Danish [1 ]
Hu, Pengfei [1 ]
Habib, Salman [2 ,3 ]
Waseem, Muhammad [1 ]
Lin, Zhenzhi [1 ]
Ahmed, Emad M. [4 ,5 ]
机构
[1] Zhejiang Univ, Coll Elect Engn, Hangzhou 310027, Peoples R China
[2] Hohai Univ, Coll Energy & Elect Engn, Nanjing 211100, Peoples R China
[3] Univ Engn & Technol, Dept Elect Engn, Lahore 54890, Pakistan
[4] Jouf Univ, Coll Engn, Dept Elect Engn, Sakaka 72388, Saudi Arabia
[5] Aswan Univ, Fac Engn, Dept Elect Engn, Aswan 81542, Egypt
关键词
Inverters; Active damping; High-pass filter; Resonance frequency; LCL filter; Grid-connected inverter (GCI); dSPACE; DESIGN; FEEDFORWARD; IMPROVE; COMPENSATION; REALIZATION; CONVERTERS; DELAY; MODE;
D O I
10.1016/j.egyr.2021.11.273
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The inverter becomes an essential part in the distributed energy units, where an inductor-capacitor- inductor (LCL) filter is an up-to-date adoption for grid interfacing. However, the challenging issue of resonance related to the LCL-filter worsens the dynamic control characteristics and produces stability threat for the voltage source inverter system. The proper design of inverter control plays a substantial part in ensuring a steady state operation and a high quality of grid injected current according to grid connection codes. This paper offers a different design method of inverter control which alters the inner damping loop structure to enhance the damping and stability features of the inverter system. In the proposed solution, a modified compensator is employed through the LCL filter network and filter capacitor current feedback loop, the resultant augmented plant's output is then sent back at the reference point of a grid-connected inverter system to damp the unwanted resonance spike. This particular arrangement to form a damping loop is termed as parallel feedforward compensation. The damping loop is implemented by calculating the filter capacitor current, and a first order high-pass filter is employed as a damper in the suggested arrangement. Moreover, for comparative studies and analysis, the conventional filter capacitor current feedback active damping method is selected. In addition, the stability margins and control performance of the open current loop are examined under different filter parameters values. The substantial results of the suggested structure are quicker dynamic response, comparatively improved resonance damping, better tracking performance and higher delay compensation capability. A laboratory prototype is established to confirm the effectiveness of the suggested scheme on the bases of control performance and stability margins.(c) 2021 The Authors. Published by Elsevier Ltd. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
引用
收藏
页码:911 / 928
页数:18
相关论文
共 45 条
[11]   Parallel Feedforward Compensation Based Active Damping of LCL-Type Grid Connected Inverter [J].
Faiz, Muhammad Talib ;
Khan, Muhammad Mansoor ;
Xu Jianming ;
Habib, Salman ;
Tang, Houjun .
2018 IEEE INTERNATIONAL CONFERENCE ON INDUSTRIAL TECHNOLOGY (ICIT), 2018, :788-793
[12]   New Design Approach for Grid-Current-Based Active Damping of LCL Filter Resonance in Grid-Connected Converters [J].
Gaafar, Mahmoud A. ;
Dousoky, Gamal M. ;
Ahmed, Emad M. ;
Shoyama, Masahito ;
Orabi, Mohamed .
JOURNAL OF POWER ELECTRONICS, 2018, 18 (04) :1165-1177
[13]   A Virtual RLC Active Damping Method for LCL-Type Grid-Connected Inverters [J].
Geng, Yiwen ;
Qi, Yawen ;
Zheng, Pengfei ;
Guo, Fei ;
Gao, Xiang .
JOURNAL OF POWER ELECTRONICS, 2018, 18 (05) :1555-1566
[14]   Contemporary Trends in Power Electronics Converters for Charging Solutions of Electric Vehicles [J].
Habib, Salman ;
Khan, Muhammad Mansoor ;
Abbas, Farukh ;
Ali, Abdar ;
Faiz, Muhammad Talib ;
Ehsan, Farheen ;
Tang, Houjun .
CSEE JOURNAL OF POWER AND ENERGY SYSTEMS, 2020, 6 (04) :911-929
[15]   VSC Input-Admittance Modeling and Analysis Above the Nyquist Frequency for Passivity-Based Stability Assessment [J].
Harnefors, Lennart ;
Finger, Raphael ;
Wang, Xiongfei ;
Bai, Haofeng ;
Blaabjerg, Frede .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2017, 64 (08) :6362-6370
[16]   Capacitor-Current Proportional-Integral Positive Feedback Active Damping for LCL-Type Grid-Connected Inverter to Achieve High Robustness Against Grid Impedance Variation [J].
He, Yuying ;
Wang, Xuehua ;
Ruan, Xinbo ;
Pan, Donghua ;
Xu, Xingping ;
Liu, Fuxin .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2019, 34 (12) :12423-12436
[17]   REALIZATION OF SIMPLE ADAPTIVE-CONTROL BY USING PARALLEL FEEDFORWARD COMPENSATOR [J].
IWAI, Z ;
MIZUMOTO, I .
INTERNATIONAL JOURNAL OF CONTROL, 1994, 59 (06) :1543-1565
[18]   Capacitor-Voltage Feedforward With Full Delay Compensation to Improve Weak Grids Adaptability of LCL-Filtered Grid-Connected Converters for Distributed Generation Systems [J].
Li, Xiaoqiang ;
Fang, Jingyang ;
Tang, Yi ;
Wu, Xiaojie ;
Geng, Yiwen .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2018, 33 (01) :749-764
[19]   Wide Damping Region for LCL-Type Grid-Connected Inverter With an Improved Capacitor-Current-Feedback Method [J].
Li, Xiaoqiang ;
Wu, Xiaojie ;
Geng, Yiwen ;
Yuan, Xibo ;
Xia, Chenyang ;
Zhang, Xue .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2015, 30 (09) :5247-5259
[20]   Damping region extension for digitally controlled LCL-type grid-connected inverter with capacitor-current feedback [J].
Liu, Jinhong ;
Zhou, Lin ;
Molinas, Marta .
IET POWER ELECTRONICS, 2018, 11 (12) :1974-1982