A resonant damping control and analysis for LCL-type grid-connected inverter

被引:20
|
作者
Khan, Danish [1 ]
Hu, Pengfei [1 ]
Habib, Salman [2 ,3 ]
Waseem, Muhammad [1 ]
Lin, Zhenzhi [1 ]
Ahmed, Emad M. [4 ,5 ]
机构
[1] Zhejiang Univ, Coll Elect Engn, Hangzhou 310027, Peoples R China
[2] Hohai Univ, Coll Energy & Elect Engn, Nanjing 211100, Peoples R China
[3] Univ Engn & Technol, Dept Elect Engn, Lahore 54890, Pakistan
[4] Jouf Univ, Coll Engn, Dept Elect Engn, Sakaka 72388, Saudi Arabia
[5] Aswan Univ, Fac Engn, Dept Elect Engn, Aswan 81542, Egypt
关键词
Inverters; Active damping; High-pass filter; Resonance frequency; LCL filter; Grid-connected inverter (GCI); dSPACE; DESIGN; FEEDFORWARD; IMPROVE; COMPENSATION; REALIZATION; CONVERTERS; DELAY; MODE;
D O I
10.1016/j.egyr.2021.11.273
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The inverter becomes an essential part in the distributed energy units, where an inductor-capacitor- inductor (LCL) filter is an up-to-date adoption for grid interfacing. However, the challenging issue of resonance related to the LCL-filter worsens the dynamic control characteristics and produces stability threat for the voltage source inverter system. The proper design of inverter control plays a substantial part in ensuring a steady state operation and a high quality of grid injected current according to grid connection codes. This paper offers a different design method of inverter control which alters the inner damping loop structure to enhance the damping and stability features of the inverter system. In the proposed solution, a modified compensator is employed through the LCL filter network and filter capacitor current feedback loop, the resultant augmented plant's output is then sent back at the reference point of a grid-connected inverter system to damp the unwanted resonance spike. This particular arrangement to form a damping loop is termed as parallel feedforward compensation. The damping loop is implemented by calculating the filter capacitor current, and a first order high-pass filter is employed as a damper in the suggested arrangement. Moreover, for comparative studies and analysis, the conventional filter capacitor current feedback active damping method is selected. In addition, the stability margins and control performance of the open current loop are examined under different filter parameters values. The substantial results of the suggested structure are quicker dynamic response, comparatively improved resonance damping, better tracking performance and higher delay compensation capability. A laboratory prototype is established to confirm the effectiveness of the suggested scheme on the bases of control performance and stability margins.(c) 2021 The Authors. Published by Elsevier Ltd. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
引用
收藏
页码:911 / 928
页数:18
相关论文
共 50 条
  • [1] Stability analysis for grid-connected LCL-Type inverter with digital control
    Kato T.
    Inoue K.
    Akiyama Y.
    Ohashi K.
    IEEJ Transactions on Industry Applications, 2016, 136 (09) : 615 - 621
  • [2] Stability Analysis for Grid-Connected LCL-Type Inverter with Digital Control
    Kato, Toshiji
    Inoue, Kaoru
    Akiyama, Yusuke
    Ohashi, Koki
    ELECTRICAL ENGINEERING IN JAPAN, 2017, 200 (02) : 34 - 42
  • [3] Stability Analysis of LCL-type Grid-connected Inverter in Weak Grid Systems
    Chen, Xin
    Gong, Chun Yin
    Wang, Hui Zhen
    Cheng, Lin
    INTERNATIONAL CONFERENCE ON RENEWABLE ENERGY RESEARCH AND APPLICATIONS (ICRERA), 2012,
  • [4] Current Harmonic Analysis of Multisampled LCL-Type Grid-connected Inverter
    He, Shan
    Pan, Yiwei
    Zhou, Dao
    Wang, Xiongfei
    Blaabjerg, Frede
    2020 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2020, : 4329 - 4335
  • [5] A New Control Scheme for LCL-type Grid-connected Inverter With a Notch Filter
    Zhao, Qiangsong
    Liang, Fen
    Li, Weifeng
    2015 27TH CHINESE CONTROL AND DECISION CONFERENCE (CCDC), 2015, : 4073 - 4077
  • [6] Multisampling Control of LCL-type Grid-connected Inverter with an Improved Repetitive Filter
    He, Shan
    Zhou, Dao
    Wang, Xiongfei
    Blaabjerg, Frede
    2020 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2020, : 4336 - 4341
  • [7] Robust Capacitor-Current-Feedback Active Damping for the LCL-Type Grid-Connected Inverter
    Pan, Donghua
    Ruan, Xinbo
    Wang, Xuehua
    Bao, Chenlei
    Li, Weiwei
    2013 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2013, : 728 - 735
  • [8] Lead compensation method for extending valid damping region of LCL-type grid-connected inverter
    Hua T.
    Lin H.
    Xiao J.
    Wang X.
    1600, Electric Power Automation Equipment Press (40): : 197 - 202
  • [9] Improved Controller of LCL-Type Grid-connected Inverter System based on Active-Damping
    Tian, Peng
    Li, Zetao
    Hao, Zhenghang
    PROCEEDINGS OF 2018 10TH INTERNATIONAL CONFERENCE ON MODELLING, IDENTIFICATION AND CONTROL (ICMIC), 2018,
  • [10] An Ignored Culprit of Harmonic Oscillation in LCL-Type Grid-Connected Inverter: Resonant Pole Cancelation
    He, Yuying
    Wang, Xuehua
    Pan, Donghua
    Ruan, Xinbo
    Su, Guoxing
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2021, 36 (12) : 14282 - 14294