The Integrity of the Acromioclavicular Capsule Ensures Physiological Centering of the Acromioclavicular Joint Under Rotational Loading

被引:48
作者
Dyrna, Felix G. E. [1 ,2 ]
Imhoff, Florian B. [1 ,2 ]
Voss, Andreas [1 ,2 ]
Braun, Sepp [1 ,2 ]
Obopilwe, Elifho [1 ]
Apostolakos, John M. [1 ]
Morikawa, Daichi [1 ,3 ]
Comer, Brendan [1 ]
Imhoff, Andreas B. [1 ,2 ]
Mazzocca, Augustus D. [1 ]
Beitzel, Knut [1 ,2 ]
机构
[1] Univ Connecticut, Hlth Ctr, Dept Orthopaed Surg, Farmington, CT USA
[2] Tech Univ Munich, Dept Orthopaed Sports Med, Franz Joseph Str 39, D-80331 Munich, Germany
[3] Juntendo Univ, Dept Orthopaed Surg, Tokyo, Japan
关键词
acromioclavicular joint; capsule; instability; biomechanics; CORACOCLAVICULAR LIGAMENT RECONSTRUCTION; DISLOCATIONS; MOTION; INSTABILITY; STABILITY; CLAVICLE; SYSTEM;
D O I
10.1177/0363546518758287
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: The acromioclavicular (AC) capsule is an important stabilizer against horizontal translation and also contributes to the strut function of the clavicle, which guides rotation of the scapula. To best reproduce the biomechanical properties and the complex 3-dimensional (3D) guidance of the AC joint, detailed knowledge of the contribution of each of the distinctive capsular structures is needed. Purpose/Hypothesis: To perform a detailed biomechanical evaluation of the specific capsular structures of the AC joint and their contribution to translational and rotational stability. The hypothesis was that successive cutting of each quadrant of the AC capsule would result in increased instability and increased amplitude of the clavicle's motion in relation to the acromion. Study Design: Controlled laboratory study. Methods: Thirty-two fresh-frozen human cadaveric shoulders were used. Each scapula was fixed to a swivel fixture of a servohydraulic materials testing system. The AC capsule was dissected in serial steps with immediate rotational and horizontal testing after each cut. A 3D optical measuring system was used to evaluate 3D movement. Posterior translation, rotation, and displacement of the lateral clavicle in relation to the center of rotation were measured. Torques and axial forces required to rotate and translate the clavicle were recorded. Results: When posterior translational force was applied, all specimens with a completely cut AC capsule demonstrated a significant loss of resistance force against the translational motion when compared with the native state (P < .05). The resistance force against posterior translation was reduced to less than 27% of the native state for all specimens. Sequential cutting of the AC capsule resulted in a significant reduction of resistance torque against anterior rotation for all specimens with less than 22% of resistance force compared with the native state. Cutting 50% of the capsule reduced the resistance torque for all segments and all testing modalities (posterior translation as well as anterior and posterior rotation) significantly compared with the native state (P < .05). Cutting the entire AC capsule resulted in a significant increase in motion within the joint as a sign of decentering of the AC joint when torque was applied. All groups demonstrated a significant increase of motion in all directions when the AC capsule was cut by 50%. Conclusion: Cutting the entire capsule (with intact coracoclavicular [CC] ligaments) reduced the resistance force to less than 25% compared with the native state during translational testing and less than 10% compared with the native state during rotational testing. However, the anterior segments of the capsule provided the greatest stability under rotational loading. Second, the amplitude of the joint's motion significantly increased under rotational stress, indicating increased amplitude of the clavicle's motion in relation to the acromion when the ligamentous structures of the AC capsule are dissected.
引用
收藏
页码:1432 / 1440
页数:9
相关论文
共 21 条
[1]   Rotational and Translational Stability of Different Methods for Direct Acromioclavicular Ligament Repair in Anatomic Acromioclavicular Joint Reconstruction [J].
Beitzel, Knut ;
Obopilwe, Elifho ;
Apostolakos, John ;
Cote, Mark P. ;
Russell, Ryan P. ;
Charette, Ryan ;
Singh, Hardeep ;
Arciero, Robert A. ;
Imhoff, Andreas B. ;
Mazzocca, Augustus D. .
AMERICAN JOURNAL OF SPORTS MEDICINE, 2014, 42 (09) :2141-2148
[2]   Biomechanical Comparison of Arthroscopic Repairs for Acromioclavicular Joint Instability Suture Button Systems Without Biological Augmentation [J].
Beitzel, Knut ;
Obopilwe, Elifho ;
Chowaniec, David M. ;
Niver, Genghis E. ;
Nowak, Michael D. ;
Hanypsiak, Bryan T. ;
Guerra, James J. ;
Arciero, Robert A. ;
Mazzocca, Augustus D. .
AMERICAN JOURNAL OF SPORTS MEDICINE, 2011, 39 (10) :2218-2225
[3]   Arthroscopically Assisted Treatment of Acute Dislocations of the Acromioclavicular Joint [J].
Braun, Sepp ;
Beitzel, Knut ;
Buchmann, Stefan ;
Imhoff, Andreas B. .
ARTHROSCOPY TECHNIQUES, 2015, 4 (06) :E681-E685
[4]   Relative contribution of acromioclavicular joint capsule and coracoclavicular ligaments to acromioclavicular stability [J].
Dawson, Patrick A. ;
Adamson, Gregory J. ;
Pink, Marilyn M. ;
Kornswiet, Matthew ;
Lin, Steven ;
Shankwiler, James A. ;
Lee, Thay Q. .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2009, 18 (02) :237-244
[5]   Ligament mechanics during three degree-of-freedom motion at the acromioclavicular joint [J].
Debski, RE ;
Parsons, IM ;
Fenwick, J ;
Vangura, A .
ANNALS OF BIOMEDICAL ENGINEERING, 2000, 28 (06) :612-618
[6]   BIOMECHANICAL STUDY OF THE LIGAMENTOUS SYSTEM OF THE ACROMIOCLAVICULAR JOINT [J].
FUKUDA, K ;
CRAIG, EV ;
AN, KN ;
COFIELD, RH ;
CHAO, EYS .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1986, 68A (03) :434-440
[7]   Intramedullary Acromioclavicular Ligament Reconstruction Strengthens Isolated Coracoclavicular Ligament Reconstruction in Acromioclavicular Dislocations [J].
Gonzalez-Lomas, Guillem ;
Javidan, Pooya ;
Lin, Tony ;
Adamson, Gregory J. ;
Limpisvasti, Orr ;
Lee, Thay Q. .
AMERICAN JOURNAL OF SPORTS MEDICINE, 2010, 38 (10) :2113-2122
[8]   Scapular Dyskinesis and SICK Scapula Syndrome in Patients With Chronic Type III Acromioclavicular Dislocation [J].
Gumina, Stefano ;
Carbone, Stefano ;
Postacchini, Franco .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2009, 25 (01) :40-45
[9]  
Inman V T, 1996, Clin Orthop Relat Res, P3, DOI 10.1097/00003086-199609000-00002
[10]  
Kibler WB, 2017, ARTHROSCOPY, V33