Cancian, Maurizio [2 ,3 ]
Scalisi, Andrea [2 ]
Pengo, Vittorio [1 ]
机构
[1] Padua Univ Hosp, Dept Cardiac Thorac Vasc Sci & Publ Hlth, Cardiol Clin, Padua, Italy
[2] Italian Coll Gen Practitioners SIMG, Florence, Italy
[3] Venetian Sch Gen Practice SVeMG, Padua, Italy
关键词
Atrial fibrillation; Large-scale screening; Silent atrial fibrillation; Automated rhythm detection; COST-EFFECTIVENESS; ROUTINE PRACTICE; AGED; 65; RISK; EPIDEMIOLOGY; PREVALENCE; MONITOR; STROKE;
D O I
10.1016/j.ijcard.2020.08.097
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Screening strategies to diagnose previously undetected atrial fibrillation (AF), especially silent AF (SAF), in at-risk populations may help reduce the number of strokes. We prospectively assessed the incidence rate of AF, including SAF, using an automated AF-detection capable sphygmomanometer in the General Practitioner (GP) setting. Methods: This was a population-based prospective study of unselected general population of >= 65 years without prior AF. Participating GPs were requested, in the period February 2018-April 2019, to record all AF diagnoses including those derived from the AF-detection capable sphygmomanometer and confirmed by 12-lead ECG or ECG Holter in asymptomatic patients. Results: Overall, 14,987 patients assisted by 76 GPs accumulated 16,838 patient-years of follow up. The incidence rate of AF was 2.25% patient-years (95%CI 2.03-2.48). AF was more frequently detected in male, older, overweight, and patients with prior stroke, congestive heart failure, and chronic kidney disease. One in four patients had device-detected SAF (0.56% patient-years, 95%CI 0.46-0.69). Age, overweight, and the number of annual visits, were independent predictors of both SAF and AF. In addition, congestive heart failure, mitral valve disease were independent predictors of AF. Due to the interaction between blood pressure and age the risk of AF increased exponentially after 75 years of age in patients with higher systolic blood pressure values. Conclusion: We found a higher than previously reported incidence rate of AF possibly by capturing SAF. Our simple protocol might be feasible in large-scale screening for AF and SAF in routine GP care. (C) 2020 Elsevier B.V. All rights reserved.
引用
收藏
页码:265 / 270
页数:6
相关论文
共 50 条
  • [21] The effect of a case-finding app on the detection rate of atrial fibrillation compared with opportunistic screening in primary care patients: protocol for a cluster randomized trial
    Beerten, Simon Gabriel
    Proesmans, Tine
    Vaes, Bert
    TRIALS, 2021, 22 (01)
  • [22] Refined atrial fibrillation screening and cost-effectiveness in the German population
    Schnabel, Renate B.
    Wallenhorst, Christopher
    Engler, Daniel
    Blankenberg, Stefan
    Pfeiffer, Norbert
    Spruenker, Ngoc Anh
    Buettner, Matthias
    Michal, Matthias
    Lackner, Karl J.
    Muenzel, Thomas
    Wild, Philipp S.
    Martinez, Carlos
    Freedman, Ben
    HEART, 2022, 108 (06) : 451 - 457
  • [23] Smartphone-based atrial fibrillation screening in the general population: feasibility and impact on medical treatment
    Gruwez, Henri
    Verbrugge, Frederik H.
    Proesmans, Tine
    Evens, Stijn
    Vanacker, Peter
    Rutgers, Matthieu Pierre
    Vanhooren, Geert
    Bertrand, Philippe
    Pison, Laurent
    Haemers, Peter
    Vandervoort, Pieter
    Nuyens, Dieter
    EUROPEAN HEART JOURNAL - DIGITAL HEALTH, 2023, 4 (06): : 464 - 472
  • [24] Blood Pressure Variability and Incidence of New-Onset Atrial Fibrillation A Nationwide Population-Based Study
    Lee, So-Ryoung
    Choi, You-Jung
    Choi, Eue-Keun
    Han, Kyung-Do
    Lee, Euijae
    Cha, Myung-Jin
    Oh, Seil
    Lip, Gregory Y. H.
    HYPERTENSION, 2020, 75 (02) : 309 - 315
  • [25] Screening of older patients for atrial fibrillation in general practice: Current evidence and its implications for future practice
    Fay, Matthew R.
    Fitzmaurice, David A.
    Freedman, Ben
    EUROPEAN JOURNAL OF GENERAL PRACTICE, 2017, 23 (01) : 246 - 253
  • [26] Validation of an ambulatory blood pressure monitoring device employing a novel method to detect atrial fibrillation
    Watanabe, Tomonori
    Tomitani, Naoko
    Yasui, Nobuhiko
    Kario, Kazuomi
    HYPERTENSION RESEARCH, 2022, 45 (08) : 1345 - 1352
  • [27] Detection of atrial fibrillation episodes using a wristband device
    Corino, Valentina D. A.
    Laureanti, Rita
    Ferranti, Lorenzo
    Scarpini, Giorgio
    Lombardi, Federico
    Mainardi, Luca T.
    PHYSIOLOGICAL MEASUREMENT, 2017, 38 (05) : 787 - 799
  • [28] Self-rated health and the risk of incident atrial fibrillation in general population
    Lee, Yonggu
    Kim, Jae Han
    Park, Jin-Kyu
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [29] Systematic screening for the detection of atrial fibrillation
    Moran, Patrick S.
    Teljeur, Conor
    Ryan, Mairin
    Smith, Susan M.
    COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2016, (06):
  • [30] Automated blood pressure measurement in atrial fibrillation: validation process modification and evaluation of a novel professional device which detects atrial fibrillation and adapts its blood pressure measurement algorithm
    Stergiou, George S.
    Kyriakoulis, Konstantinos G.
    Bountzona, Ioanna
    Menti, Ariadni
    Destounis, Antonios
    Kalogeropoulos, Petros
    Kollias, Anastasios
    JOURNAL OF HYPERTENSION, 2021, 39 (04) : 614 - 620