Comparative efficacy and safety of vaginal misoprostol versus dinoprostone vaginal insert in labor induction at term: a randomized trial

被引:34
作者
Ozkan, Sebiha [1 ,2 ]
Caliskan, Eray [2 ]
Doger, Emek [2 ]
Yucesoy, Izzet [2 ]
Ozeren, Semih [2 ]
Vural, Birol [2 ]
机构
[1] Guney Mahallesi, Tupras Sitesi, TR-41780 Korfez Kocaeli, Turkey
[2] Kocaeli Univ, Dept Obstet & Gynecol, Sch Med, Kocaeli, Turkey
关键词
Misoprostol; Dinoprostone; Labor induction; FETAL HEART-RATE; PROSTAGLANDIN E-2; INTRACERVICAL DINOPROSTONE; ORAL MISOPROSTOL; GEL;
D O I
10.1007/s00404-008-0843-9
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
To compare efficacy and safety of vaginal misoprostol (PGE(1) analog) with dinoprostone (PGE(2) analog) vaginal insert for labor induction in term pregnancies. A total of 112 women with singleton pregnancies of a parts per thousand yen37 weeks of gestation, and low Bishop scores underwent labor induction. The subjects were randomized to receive either 50 mu g misoprostol intravaginally every 4 h to a maximum of five doses or a 10 mg dinoprostone vaginal insert for a maximum of 12 h. Time interval from induction to vaginal delivery, vaginal delivery rates within 12 and 24 h, requirement of oxytocin augmentation, incidence of tachysystole and uterine hyperstimulation, mode of delivery, rate of cesarean section due to fetal distress and neonatal outcome were outcome measures. Student's t test, Chi square test, Fischer's exact test were used for statistical analysis. Time interval from induction to vaginal delivery was found to be significantly shorter in misoprostol group when compared to dinoprostone subjects (680 +/- A 329 min vs. 1070 +/- A 435 min, P < 0.001). Vaginal delivery rates within 12 h were found to be significantly higher with misoprostol induction [n = 37 (66%) vs. n = 25 (44.6%); P = 0.02], whereas vaginal delivery rates in 24 h did not differ significantly between groups [n = 41 (73.2%) vs. n = 36 (64.2%); P = 0.3]. More subjects required oxytocin augmentation in dinoprostone group [n = 35 (62.5%) vs. n = 20 (35.7%), P = 0.005] and cardiotocography tracings revealed early decelerations occurring more frequently with misoprostol induction (10.7 vs. 0%, P = 0.03). Tachysystole and uterine hyperstimulation, mode of delivery, rate of cesarean sections due to fetal distress and adverse neonatal outcome were not demonstrated to be significantly different between groups (P = 1, P = 0.5, P = 0.4, P = 0.22, P = 0.5). Using vaginal misoprostol is an effective way of labor induction in term pregnant women with unfavorable cervices, since it is associated with a shorter duration of labor induction and higher rates of vaginal delivery within 12 h. Misoprostol and dinoprostone are equally safe, since misoprostol did not result in a rise in maternal and neonatal morbidity, namely, tachysystole, uterine hyperstimulation, cesarean section rates and admission to neonatal intensive care units as reported previously in literature.
引用
收藏
页码:19 / 24
页数:6
相关论文
共 24 条
[1]   Six hourly vaginal misoprostol versus intracervical dinoprostone for cervical ripening and labor induction [J].
Agarwal, N ;
Gupta, A ;
Kriplani, A ;
Bhatla, N ;
Parul .
JOURNAL OF OBSTETRICS AND GYNAECOLOGY RESEARCH, 2003, 29 (03) :147-151
[2]  
*AM COLL OBST GYN, 1995, ACOG TECHN B, V217
[3]   A randomized comparison between misoprostol and dinoprostone for cervical ripening and labor induction in patients with unfavorable cervices [J].
Buser, D ;
Mora, G ;
Arias, F .
OBSTETRICS AND GYNECOLOGY, 1997, 89 (04) :581-585
[4]   Intracervical misoprostol and prostaglandin E2 for labor induction [J].
Chang, YK ;
Chen, WH ;
Yu, MH ;
Liu, HS .
INTERNATIONAL JOURNAL OF GYNECOLOGY & OBSTETRICS, 2003, 80 (01) :23-28
[5]   Fetal Doppler hemodynamic changes in spontaneous versus prostaglandin E1-induced active labor [J].
Chen, WH ;
Lai, HC ;
Tang, YH ;
Liu, HS .
ACTA OBSTETRICIA ET GYNECOLOGICA SCANDINAVICA, 1999, 78 (07) :599-604
[6]   Oral misoprostol or vaginal dinoprostone for labor induction:: A randomized controlled trial [J].
Dällenbach, P ;
Boulvain, M ;
Viardot, C ;
Irion, O .
AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2003, 188 (01) :162-167
[7]   A multicenter controlled trial of fetal pulse oximetry in the intrapartum management of nonreassuring fetal heart rate patterns [J].
Garite, TJ ;
Dildy, GA ;
McNamara, H ;
Nageotte, MP ;
Boehm, FH ;
Dellinger, EH ;
Knuppel, RA ;
Porreco, RP ;
Miller, HS ;
Sunderji, S ;
Varner, MW ;
Swedlow, DB .
AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2000, 183 (05) :1049-1058
[8]  
Garry D, 2003, J Matern Fetal Neonatal Med, V13, P254, DOI 10.1080/713605867
[9]   A randomised controlled trial comparing low dose vaginal misoprostol and dinoprostone vaginal gel for inducing labour at term [J].
Gregson, S ;
Waterstone, M ;
Norman, I ;
Murrells, T .
BJOG-AN INTERNATIONAL JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 2005, 112 (04) :438-444
[10]   Dinoprostone vaginal insert for cervical ripening and labor induction: A meta-analysis [J].
Hughes, EG ;
Kelly, AJ ;
Kavanagh, J .
OBSTETRICS AND GYNECOLOGY, 2001, 97 (05) :847-855