Influence of fire on temperature gradient and physical-mechanical properties of macro-synthetic fiber reinforced concrete for tunnel linings

被引:36
作者
Serafini, Ramoel [1 ,3 ]
Dantas, Sergio R. A. [1 ]
Salvador, Renan P. [1 ,2 ]
Agra, Ronney R. [1 ,3 ]
Rambo, Dimas A. S. [2 ]
Berto, Antonio F. [3 ]
de Figueiredo, Antonio D. [1 ]
机构
[1] Univ Sao Paulo, Polytech Sch, Dept Civil Construct Engn, Ave Prof Almeida Prado,Travessa 2,83, BR-05424970 Sao Paulo, Brazil
[2] Univ Sao Judas Tadeu, Dept Civil Engn, Rua Taquari 546, BR-03166000 Sao Paulo, Brazil
[3] Inst Technol Res, Ave Prof Almeida Prado 532, BR-05508901 Sao Paulo, Brazil
基金
巴西圣保罗研究基金会;
关键词
Fire; Temperature gradient; Mechanical properties; Macro-synthetic fiber reinforced concrete; Tunneling; FLY-ASH; THERMAL-STABILITY; PORTLAND-CEMENT; FRC; PERFORMANCE; HYDRATION; STRENGTH; POROSITY; CALCIUM; DESIGN;
D O I
10.1016/j.conbuildmat.2019.04.133
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This study aims to evaluate the effect of fire on the physical, mechanical, and microstructural properties of macro-synthetic fiber reinforced concrete. Results demonstrated that internal heating rate is constant through time and is a function of the distance from the fire. Temperature gradient values are nonlinear, reduce at greater distances from the heated surface and with the duration of the fire. Microstructural analysis shows the severe dehydration of hydrated products, which negatively influences the mechanical properties of the composite. Above 205 degrees C the formation of nesosilicates is verified. Residual flexural strength values reduce by over 85% after the fire exposure due to deterioration of the reinforcing mechanism. Compressive strength and elastic modulus drastically reduce with temperature increase. The present study contributes to the absent literature on the post-fire mechanical behavior of MSFRC, suggests an alternative approach to the post-fire evaluation of tunnel structures, and aids in the definition of post-fire safety parameters. (C) 2019 Elsevier Ltd. All rights reserved.
引用
收藏
页码:254 / 268
页数:15
相关论文
共 56 条
[1]   Dehydration and rehydration processes of cement paste exposed to high temperature environments [J].
Alonso, C ;
Fernandez, L .
JOURNAL OF MATERIALS SCIENCE, 2004, 39 (09) :3015-3024
[2]  
[Anonymous], 2003, LEAS CHEM CEMENT CON
[3]  
[Anonymous], 2002, EN 1991-1-2
[4]  
[Anonymous], 2015, ASTM ASTM E1876-15, V1, P15, DOI [10.1520/E1876-15, DOI 10.1520/E1876-15]
[5]  
[Anonymous], 2014, CRC Handbook of Chemistry and Physics, V95th, P3, DOI DOI 10.1201/B17118
[6]  
[Anonymous], 2007, 14651 EN
[7]  
Baiant Z. P., 1996, CONCRETE HIGH TEMPER
[8]   Structural behaviour of precast tunnel segments in fiber reinforced concrete [J].
Caratelli, Angelo ;
Meda, Alberto ;
Rinaldi, Zila ;
Romualdi, Paolo .
TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2011, 26 (02) :284-291
[9]   Influence of thermal damage on physical properties of a granite rock: Porosity, permeability and ultrasonic wave evolutions [J].
Chaki, S. ;
Takarli, M. ;
Agbodjan, W. P. .
CONSTRUCTION AND BUILDING MATERIALS, 2008, 22 (07) :1456-1461
[10]   Barcelona test for the evaluation of the mechanical properties of single and hybrid FRC, exposed to elevated temperature [J].
Choumanidis, D. ;
Badogiannis, E. ;
Nomikos, P. ;
Sofianos, A. .
CONSTRUCTION AND BUILDING MATERIALS, 2017, 138 :296-305