The isolated perfused porcine kidney model for investigations concerning surgical therapy procedures

被引:0
作者
Peters, Kristina
Haecker, Axel
Michel, Maurice Stephan
Matis, Ulrich
机构
[1] Heidelberg Univ, Fak Klin Med Mannheim, Univ Klinikum Mannheim, Urol Klin, D-6900 Heidelberg, Germany
[2] Univ Munich, Fak Vet Med, Chirurg Tierklin, Munich, Germany
来源
ALTEX-ALTERNATIVEN ZU TIEREXPERIMENTEN | 2006年 / 23卷 / 03期
关键词
3R; organmodel; surgical innovations; kidney;
D O I
暂无
中图分类号
R [医药、卫生];
学科分类号
10 ;
摘要
Experiments to develop innovative surgical therapy procedures are conventionally conducted on animals, as crucial aspects like tissue removal and bleeding disposition cannot be investigated in vitro. Extracorporeal organ models however reflect these aspects and could thus reduce the use of animals for this purpose fundamentally in the future. The aim of this work was to validate the isolated perfused porcine kidney model with regard to its use for surgical purposes on the basis of histological and radiological procedures. The results show that neither storage nor artificial perfusion led to any structural or functional damage which would affect the quality of the organ. The kidney model is highly suitable for simulating the main aspects of renal physiology and allows a constant calibration of perfusion pressure and tissue temperature. Thus, with only a moderate amount of work involved, the kidney model provides a cheap and readily available alternative to conventional animal experiments; it allows standardised experimental settings and provides valid results.
引用
收藏
页码:203 / 207
页数:5
相关论文
共 19 条
[11]   Controlled study of inline radiofrequency coagulation-assisted partial nephrectomy in sheep [J].
Haghighi, Koroush S. ;
Steinke, Karin ;
Hazratwala, Kiran ;
Kam, Peter C. A. ;
Daniel, Steven ;
Morris, David L. .
JOURNAL OF SURGICAL RESEARCH, 2006, 133 (02) :215-218
[12]   Evaluation of superficial papillary ablation by endoscopic lasers in an ex vivo kidney model [J].
Knoll, T ;
Michel, MS ;
Cueva-Martínez, A ;
Spahn, M ;
Bross, S ;
Alken, P ;
Köhrmann, KU .
JOURNAL OF ENDOUROLOGY, 2002, 16 (03) :195-200
[13]   THE ISOLATED-PERFUSED KIDNEY OF THE PIG - NEW MODEL TO EVALUATE SHOCK WAVE-INDUCED LESIONS [J].
KOHRMANN, KU ;
BACK, W ;
BENSEMANN, J ;
FLORIAN, J ;
WEBER, A ;
KAHMANN, F ;
RASSWEILER, J ;
ALKEN, P .
JOURNAL OF ENDOUROLOGY, 1994, 8 (02) :105-110
[14]   Rotoresect: New technique for resection of the prostate: Experimental phase [J].
Michel, MS ;
Kohrmann, KU ;
Weber, A ;
Krautschick, AW ;
Alken, P .
JOURNAL OF ENDOUROLOGY, 1996, 10 (05) :473-478
[15]   Pig kidney: Anatomical relationships between the intrarenal arteries and the kidney collecting system. Applied study for urological research and surgical training [J].
Pereira-Sampaio, MA ;
Favorito, LA ;
Sampaio, FJB .
JOURNAL OF UROLOGY, 2004, 172 (05) :2077-2081
[16]   Ex vivo training model for percutaneous renal surgery [J].
Strohmaier, WL ;
Giese, A .
UROLOGICAL RESEARCH, 2005, 33 (03) :191-193
[17]   The Vista system:: A new bipolar resection device for endourological procedures:: Comparison with conventional resectoscope [J].
Wendt-Nordahl, G ;
Häcker, A ;
Reich, O ;
Djavan, B ;
Alken, P ;
Michel, MS .
EUROPEAN UROLOGY, 2004, 46 (05) :586-590
[18]   In vivo laser-induced interstitial thermotherapy of pig liver with a temperature-controlled diode laser and MRI correlation [J].
Wohlgemuth, WA ;
Wamser, G ;
Reiss, T ;
Wagner, T ;
Bohndorf, K .
LASERS IN SURGERY AND MEDICINE, 2001, 29 (04) :374-378
[19]   Microbubbles assist goat liver ablation by high intensity focused ultrasound [J].
Yu, Tinghe ;
Fan, Xionglin ;
Xiong, Shuhua ;
Hu, Kai ;
Wang, Zhibiao .
EUROPEAN RADIOLOGY, 2006, 16 (07) :1557-1563