Applied Taguchi method for fatigue testing of customized hip implant

被引:2
|
作者
Dharme, Mangesh R. [1 ]
Kuthe, Abhaykumar M. [1 ]
Deshmukh, Tushar R. [2 ]
机构
[1] Visvesvaraya Natl Inst Technol, Dept Mech Engn, Nagpur, Maharashtra, India
[2] Prof Ram Meghe Inst Technol & Res, Dept Mech Engn, Amravati, India
关键词
Experimental model; Fatigue; Finite element analysis; Gait cycle; Orthogonal array; Taguchi methods; FINITE-ELEMENT-ANALYSIS; 3-DIMENSIONAL SHAPE OPTIMIZATION; FEMORAL STEMS; INDIAN POPULATION; WALKING ACTIVITY; CONTACT FORCES; COBALT CHROME; ARTHROPLASTY; PROSTHESIS; JOINT;
D O I
10.5301/ijao.5000545
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Purpose: Human activities generate stresses, which vary with time and may result in fatigue failure of the customized hip implant. This study aims to investigate fatigue testing of customized hip implants using the minimum number of experiments by the Taguchi method, for 147 patients. This study was also useful to determine the influential geometrical parameters on the fatigue safety factor of customized hip implants. Methods: Horizontal offset (HO), vertical offset (VO) and neck shaft angle (NSA) of the hip joint of 147 patients were measured on computed tomography (CT) scanned images. Stress and strain of hip implants were calculated by finite element analysis and validated by in vitro experimental tests. Fatigue safety factors were calculated by Goodman, Soderberg and Gerber's fatigue theories and maximum stresses. Results: Analysis of variance results show that the highest impact on fatigue safety factors was equal to 54.38% for HO, 16.33% for VO, and was equal to 29.16% for NSA with reference to Goodman, Soderberg and Gerber's fatigue theories. The hip implant shape of experiment no. 8 has the highest safety factor value compared to all other hip implants. Conclusions: The results show that HO has the maximum influence on fatigue safety factors. The determination of influential geometric parameters may be useful to redesign customized hip implants in order to achieve the highest fatigue safety factor. The Taguchi method is suitable for fatigue testing of custom hip implant with a minimum number of experiments.
引用
收藏
页码:611 / 618
页数:8
相关论文
共 50 条
  • [1] Design and Analysis of Customized Hip Implant Using Finite Element Method
    Priya, M. Anu
    Snekhalatha, U.
    Mahalakshmi, R.
    Dhivya, T.
    Gupta, Nilkantha
    ARTIFICIAL INTELLIGENCE AND EVOLUTIONARY COMPUTATIONS IN ENGINEERING SYSTEMS, 2020, 1056 : 515 - 525
  • [2] Finite element analysis and fatigue test prediction applied to the standard fatigue testing of hip stems
    Ploeg, HL
    Wevers, HW
    Wyss, UP
    Bürgi, M
    COMPUTER METHODS IN BIOMECHANICS & BIOMEDICAL ENGINEERING - 2, 1998, : 139 - 146
  • [3] Static, dynamic and fatigue behaviors of dental implant using finite element method
    Kayabasi, Oguz
    Yuezbasioglu, Emir
    Erzincanli, Fehmi
    ADVANCES IN ENGINEERING SOFTWARE, 2006, 37 (10) : 649 - 658
  • [4] Numerical analysis of fatigue crack growth of hip implant
    Sedmak, Aleksandar
    Colic, Katarina
    Grbovic, Aleksandar
    Balac, Igor
    Burzic, Meri
    ENGINEERING FRACTURE MECHANICS, 2019, 216
  • [5] Effects of Hip Implant Modular Neck Material and Assembly Method on Fatigue Life and Distraction Force
    Aljenaei, Fahad
    Catelas, Isabelle
    Louati, Hakim
    Beaule, Paul E.
    Nganbe, Michel
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2017, 35 (09) : 2023 - 2030
  • [6] Fatigue behaviour of dental implant using finite element method
    Kumar Srivastav C.
    Kapoor R.
    Khan D.
    Materials Today: Proceedings, 2022, 56 : 1143 - 1150
  • [7] Fatigue strength testing of hip stems with statistical analysis
    Ploeg, HL
    Wevers, HW
    Wyss, UP
    Bürgi, M
    BIO-MEDICAL MATERIALS AND ENGINEERING, 1999, 9 (04) : 243 - 263
  • [8] Fatigue Testing of a New Locking Plate for Hip Fractures
    Hunt, Stephen
    Martin, Rod
    Woolridge, Bryan
    JOURNAL OF MEDICAL AND BIOLOGICAL ENGINEERING, 2012, 32 (02) : 117 - 122
  • [9] Resistance of three implant-abutment interfaces to fatigue testing
    Ribeiro, Cleide Gisele
    Cabral Maia, Maria Luiza
    Scherrer, Susanne S.
    Cardoso, Antonio Carlos
    Anselm Wiskott, H. W.
    JOURNAL OF APPLIED ORAL SCIENCE, 2011, 19 (04) : 413 - 420
  • [10] Efficient computational method for assessing the effects of implant positioning in cementless total hip replacements
    Bah, Mamadou T.
    Nair, Prasanth B.
    Taylor, Mark
    Browne, Martin
    JOURNAL OF BIOMECHANICS, 2011, 44 (07) : 1417 - 1422