Porphyrins in analytical chemistry. A review

被引:464
作者
Biesaga, M [1 ]
Pyrzynska, K [1 ]
Trojanowicz, M [1 ]
机构
[1] Univ Warsaw, Dept Chem, PL-02093 Warsaw, Poland
关键词
porphyrins; metalloporphyrins; preconcentration; HPLC stationary phases;
D O I
10.1016/S0039-9140(99)00291-X
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The porphyrins, naturally occurring macrocyclic compounds, have, in the last 10 years, gained increasing interest in analytical chemistry. This review based on 123 original literature references, mostly published in the 1990s, presents catalytic applications of metalloporphyrins in electroanalysis as electroactive agents in ion selective membranes, as unique reagents in spectrophotometry and as new stationary phases offering unusual resolution in HPLC. The collected data are also presented in four tables. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:209 / 224
页数:16
相关论文
共 123 条
[1]   ANION SELECTIVITY OF METALLOPORPHYRINS IN MEMBRANES [J].
AMMANN, D ;
HUSER, M ;
KRAUTLER, B ;
RUSTERHOLZ, B ;
SCHULTHESS, P ;
LINDEMANN, B ;
HALDER, E ;
SIMON, W .
HELVETICA CHIMICA ACTA, 1986, 69 (04) :849-854
[2]   Electrochemical detection of NADH and dopamine in flow analysis based on tetraruthenated porphyrin modified electrodes [J].
Angnes, L ;
Azevedo, CMN ;
Araki, K ;
Toma, HE .
ANALYTICA CHIMICA ACTA, 1996, 329 (1-2) :91-95
[3]   Chemically modified field effect transistors with nitrite or fluoride selectivity [J].
Antonisse, MMG ;
Snellink-Ruel, BHM ;
Engbersen, JFJ ;
Reinhoudt, DN .
JOURNAL OF THE CHEMICAL SOCIETY-PERKIN TRANSACTIONS 2, 1998, (04) :773-777
[4]   ELECTROCHEMISTRY OF A TETRARUTHENATED COBALT PORPHYRIN AND ITS USE IN MODIFIED ELECTRODES AS SENSORS OF REDUCING ANALYTES [J].
ARAKI, K ;
ANGNES, L ;
AZEVEDO, CMN ;
TOMA, HE .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1995, 397 (1-2) :205-210
[5]  
Atanasov P, 1996, ELECTROANAL, V8, P158, DOI 10.1002/elan.1140080212
[6]  
Azevedo CMN, 1998, ELECTROANAL, V10, P467, DOI 10.1002/(SICI)1521-4109(199806)10:7<467::AID-ELAN467>3.0.CO
[7]  
2-W
[8]   CARBON-FIBER ULTRAMICROELECTRODES MODIFIED WITH CONDUCTIVE POLYMERIC TETRAKIS(3-METHOXY-4-HYDROXYPHENYL)PORPHYRIN FOR DETERMINATION OF NICKEL IN SINGLE BIOLOGICAL CELLS [J].
BAILEY, F ;
MALINSKI, T ;
KIECHLE, F .
ANALYTICAL CHEMISTRY, 1991, 63 (04) :395-398
[9]   ANION-SELECTIVE MEMBRANE ELECTRODES BASED ON METALLOPORPHYRINS - THE INFLUENCE OF LIPOPHILIC ANIONIC AND CATIONIC SITES ON POTENTIOMETRIC SELECTIVITY [J].
BAKKER, E ;
MALINOWSKA, E ;
SCHILLER, RD ;
MEYERHOFF, ME .
TALANTA, 1994, 41 (06) :881-890
[10]   Design and characterization of chemically modified electrodes with iron(III) porphyrinic-based polymers: Study of their reactivity toward nitrites and nitric oxide in aqueous solution [J].
Bedioui, F ;
Trevin, S ;
Albin, V ;
Villegas, MGG ;
Devynck, J .
ANALYTICA CHIMICA ACTA, 1997, 341 (2-3) :177-185