Consistency of Continuous Ambulatory Interstitial Glucose Monitoring Sensors

被引:4
|
作者
Wu, Pei T. [1 ,2 ]
Segovia, David E. [3 ,4 ]
Lee, Cathy C. [3 ,4 ]
Nguyen, Kim-Lien [1 ,2 ]
机构
[1] UCLA, David Geffen Sch Med, Div Cardiol, Los Angeles, CA 90024 USA
[2] VA Greater Los Angeles Healthcare Syst, Los Angeles, CA 90024 USA
[3] UCLA, David Geffen Sch Med, Dept Geriatr, Los Angeles, CA 90095 USA
[4] VA Greater Los Angeles Healthcare Syst, GRECC, Los Angeles, CA 90095 USA
来源
BIOSENSORS-BASEL | 2018年 / 8卷 / 02期
关键词
continuous glucose monitoring; interstitial glucose sensors; intra-subject agreement; postprandial glucose; BLOOD-GLUCOSE; ACCURACY; PERFORMANCE; SYSTEM; FLOW;
D O I
10.3390/bios8020049
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Aims: The abdominal region is the most common location for continuous glucose monitor (CGM) sensor insertion. However, a paucity of post-marketing data is available to demonstrate intra-individual consistency of CGM readings at different abdominal insertion sites. Methods: Healthy adults (fasting glucose (FG) < 5.5 mmol/L; BMI < 30 kg/m(2)) were recruited and a CGM sensor was placed on each side of the abdomen. Postprandial and continuous 48-h interstitial glucose levels were analyzed. Results: There was no significant difference in the 3-h postprandial glucose (PPG) level derived from the left versus right CGM, which remained non-significant after adjusting for waist circumference or FG. Among the glucose levels recorded over 48-h, values on the left site were greater in 3.6% of the data points (p < 0.05). After adjusting for waist circumference, only 0.5% of the glucose values remained significantly greater on the left (p < 0.05). When adjusted for FG, similar results were observed. For both PPG and 48-h readings, the mean absolute relative difference was not significant between the two abdominal sites. Conclusions: CGM-derived glucose measures were highly consistent between the left and right abdomen during both the postprandial and post-absorptive periods.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Comprehensive Review on Wearable Sweat-Glucose Sensors for Continuous Glucose Monitoring
    Zafar, Hima
    Channa, Asma
    Jeoti, Varun
    Stojanovic, Goran M.
    SENSORS, 2022, 22 (02)
  • [22] Wearable Continuous Glucose Monitoring Sensors: A Revolution in Diabetes Treatment
    Cappon, Giacomo
    Acciaroli, Giada
    Vettoretti, Martina
    Facchinetti, Andrea
    Sparacino, Giovanni
    ELECTRONICS, 2017, 6 (03):
  • [23] Multivariate calibration of NIR spectroscopic sensors for continuous glucose monitoring
    Goodarzi, Mohammad
    Sharma, Sandeep
    Ramon, Herman
    Saeys, Wouter
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2015, 67 : 147 - 158
  • [24] DYNAMIC INTERFERENCE TEST METHOD FOR CONTINUOUS GLUCOSE MONITORING SENSORS
    Pfuetzner, A.
    Jensch, H.
    Srikanthamoorthy, G.
    Thome, N.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2023, 25 : A162 - A163
  • [25] Accuracy and Potential Interferences of Continuous Glucose Monitoring Sensors in the Hospital
    Bellido, Virginia
    Freckman, Guido
    Perez, Antonio
    Galindo, Rodolfo J.
    ENDOCRINE PRACTICE, 2023, 29 (11) : 919 - 927
  • [26] COMPARISON OF DIFFERENT CALIBRATION STRATEGIES FOR CONTINUOUS GLUCOSE MONITORING SENSORS
    Vettoretti, M.
    Facchinetti, A.
    Sparacino, G.
    Del Favero, S.
    Cobelli, C.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2014, 16 : A16 - A16
  • [27] Assessment of the variance of the ambulatory glucose profile over 3 to 20 days of continuous glucose monitoring
    Dunn, T. C.
    Crouther, N.
    DIABETOLOGIA, 2010, 53
  • [28] Characterizing glucose exposure for individuals with normal glucose tolerance using continuous glucose monitoring and ambulatory glucose profile analysis
    Mazze, Roger S.
    Strock, Ellie
    Wesley, David
    Borgman, Sarah
    Morgan, Blaine
    Bergenstal, Richard
    Cuddihy, Robert
    DIABETES TECHNOLOGY & THERAPEUTICS, 2008, 10 (03) : 149 - 159
  • [29] Impact of professional continuous glucose monitoring by clinical pharmacists in an ambulatory care setting
    Van Dril, Elizabeth
    Schumacher, Christie
    JOURNAL OF THE AMERICAN COLLEGE OF CLINICAL PHARMACY, 2019, 2 (06): : 638 - 644
  • [30] LOW NOISE MEASUREMENT OF PHOTOCURRENT FOR CONTINUOUS GLUCOSE MONITORING Low Noise Measurement System Enables Continuous Monitoring of Glucose in Subcutaneous Interstitial Fluid
    Cooley, Daniel W.
    Andersen, David R.
    BIODEVICES 2010: PROCEEDINGS OF THE THIRD INTERNATIONAL CONFERENCE ON BIOMEDICAL ELECTRONICS AND DEVICES, 2010, : 195 - 200