Percutaneous image-guided core biopsy of solid renal masses: analysis of safety, efficacy, pathologic interpretation, and clinical significance

被引:11
作者
Alle, Nisha [1 ,5 ]
Tan, Nelly [1 ]
Huss, Julie [3 ]
Huang, Jiatoi [4 ]
Pantuck, Allan [2 ]
Raman, Steven S. [1 ,2 ]
机构
[1] Univ Calif Los Angeles, David Geffen Sch Med, Dept Radiol, Los Angeles, CA 90095 USA
[2] Univ Calif Los Angeles, David Geffen Sch Med, Dept Urol, Los Angeles, CA 90095 USA
[3] Univ Calif Los Angeles, David Geffen Sch Med, Dept Pathol, Los Angeles, CA 90095 USA
[4] Duke Univ, Sch Med, Dept Pathol, Durham, NC 27706 USA
[5] Ronald Reagan UCLA Med Ctr, Dept Radiol, 757 Westwood Plaza,Suite 1638, Los Angeles, CA 90095 USA
关键词
Renal mass biopsy; Renal cell carcinoma; Intervention; FINE-NEEDLE-ASPIRATION; CELL CARCINOMA; COMPUTERIZED-TOMOGRAPHY; ACCURACY; TUMORS; DIAGNOSIS; LESIONS; MANAGEMENT; IMPACT; SUBTYPES;
D O I
10.1007/s00261-017-1337-7
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To determine the efficacy, safety and clinical utility of CT and US-guided percutaneous renal mass biopsy. A retrospective IRB-approved, HIPAA-compliant study of a cohort of 183 consecutive patients who underwent percutaneous, CT or US-guided renal mass biopsy (RMB) from March 2002 through December 2012 was performed. RMB was performed in 183 consecutive patients for suspected solid renal mass of whom 14/183 (7.7%) were excluded because biopsies were performed at an outside institution, medical records were incomplete, or lesions were poorly visualized. Ten patients had multiple biopsies for new growing masses. Using US, CT or CT/US fusion-guidance, a 17G or 19G cannula needle was placed at the margin of the mass and an 18G or 20G core biopsy gun was used to obtain several tissue cores. Renal parenchymal biopsies for medical renal diseases were excluded. Imaging variables (including size, location, and extent of disease), number of core biopsies, patient demographics (age, gender), clinical indication, final pathologic diagnosis, immunohistochemical (IHC) studies, and subsequent final pathological diagnosis on nephrectomy were evaluated. Of the 169 patients with 184 RMB, 121/169 (71.6%) were male with a mean age of 67.5 years. Of 184 RMB, 126 were malignant [126/184 (68.5%)], 37 [37/184 (20.1%)], were benign, and 21 (21/184 (11.4%) were nondiagnostic. IHC was performed in 131 biopsies (71.1%) and was diagnostic in 88.5% of those cases. Twenty-eight patients underwent subsequent partial nephrectomy; in 27/27 (100%) cases, RMB was concordant with nephrectomy for malignancy and in 21/27 (77.8%) RMB was concordant for subtype of RCC. Overall, the RMB sensitivity for detection of malignancy, specificity, and positive predictive value were 100%. The negative predictive value of benign RMB diagnosis was also 100%. There was a total of 14 (7.6%) complications, 13 minor (7.1%) and 1 major (0.5%). Of the minor complications, ten (5.5%) were postprocedural minor hematomas that resolved conservatively; one (0.5%) postprocedural vasovagal reaction; one (0.5%) episode of hematuria; and one (0.5%) episode of nausea and abdominal discomfort. No cases of renal pseudoaneurysm or tumor seeding attributed to biopsy were identified. Percutaneous image-guided RMB is safe and highly diagnostic when combined with IHC and supports a greater role of RMB and imaging in evaluating renal masses when rendering appropriate treatments.
引用
收藏
页码:1813 / 1819
页数:7
相关论文
共 31 条
[1]   Diagnosis of renal tumors on needle biopsy specimens by histological and molecular analysis [J].
Barocas, D. A. ;
Rohan, S. M. ;
Kao, J. ;
Gurevich, R. D. ;
Del Pizzo, J. J. ;
Vaughan, E. D., Jr. ;
Akhtar, M. ;
Chen, Y. -T. ;
Scherr, D. S. .
JOURNAL OF UROLOGY, 2006, 176 (05) :1957-1962
[2]   Renal cell carcinoma sub-typing by histopathology and fluorescence in situ hybridization on a needle-biopsy specimen [J].
Barocas, Daniel A. ;
Mathew, Susan ;
DelPizzo, Joseph J. ;
Darracott Vaughan, E., Jr. ;
Sosa, R. Ernest ;
Fine, Ronnie G. ;
Akhtar, Mohamed ;
Scherr, Douglas S. .
BJU INTERNATIONAL, 2007, 99 (02) :290-295
[3]   Evaluation of fine-needle aspiration cytology for renal masses [J].
Brierly, RB ;
Thomas, PJ ;
Harrison, NW ;
Fletcher, MS ;
Nawrocki, JD ;
Ashton-Key, M .
BJU INTERNATIONAL, 2000, 85 (01) :14-18
[4]   Prospective evaluation of fine needle aspiration of small, solid renal masses: Accuracy and morbidity [J].
Campbell, SC ;
Novick, AC ;
Herts, B ;
Fischler, DF ;
Meyer, J ;
Levin, HS ;
Chen, RN .
UROLOGY, 1997, 50 (01) :25-29
[5]   CONVENTIONAL 15G NEEDLE TECHNIQUE FOR RENAL BIOPSY COMPARED WITH ULTRASOUND-GUIDED SPRING-LOADED 18G NEEDLE-BIOPSY [J].
COZENS, NJA ;
MURCHISON, JT ;
ALLAN, PL ;
WINNEY, RJ .
BRITISH JOURNAL OF RADIOLOGY, 1992, 65 (775) :594-597
[6]   Prospective analysis of computerized tomography and needle biopsy with permanent sectioning to determine the nature of solid renal masses in adults [J].
Dechet, CB ;
Zincke, H ;
Sebo, TJ ;
King, BF ;
LeRoy, AJ ;
Farrow, GM ;
Blute, ML .
JOURNAL OF UROLOGY, 2003, 169 (01) :71-74
[7]   Pathologic characteristics of solitary small renal masses [J].
DeRoche, Tom ;
Walker, Esteban ;
Magi-Galluzzi, Cristina ;
Zhou, Min .
AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2008, 130 (04) :560-564
[8]   Solid renal tumors: An analysis of pathological features related to tumor size [J].
Frank, I ;
Blute, ML ;
Cheville, JC ;
Lohse, CM ;
Weaver, AL ;
Zincke, H .
JOURNAL OF UROLOGY, 2003, 170 (06) :2217-2220
[9]  
Gattuso P, 1999, DIAGN CYTOPATHOL, V21, P35, DOI 10.1002/(SICI)1097-0339(199907)21:1<35::AID-DC10>3.0.CO
[10]  
2-#