The accuracy of a hand-held navigation system in total knee arthroplasty

被引:5
作者
Loh, Bryan [1 ]
Chen, Jerry Yongqiang [1 ]
Yew, Andy Khye Soon [1 ]
Pang, Hee Nee [1 ]
Tay, Darren Keng Jin [1 ]
Chia, Shi-Lu [1 ]
Lo, Ngai Nung [1 ]
Yeo, Seng Jin [1 ]
机构
[1] Singapore Gen Hosptial, Dept Orthopaed Surg, 20 Coll Rd, Singapore 169856, Singapore
关键词
Hand-held navigation; Total knee arthroplasty; Lower limb alignment; Implant placement; RANDOMIZED CONTROLLED-TRIAL; COMPUTER NAVIGATION; CORONAL ALIGNMENT; TIBIAL RESECTION; NO DIFFERENCE; REPLACEMENT; FRACTURE; OUTCOMES; SURGERY;
D O I
10.1007/s00402-016-2612-8
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
This study aims to evaluate the effectiveness of a new hand-held navigation system. The authors of this study hypothesize that this navigation system will improve overall lower limb alignment and implant placement without causing a delay in surgery. Two hundred consecutive patients diagnosed with tricompartmental osteoarthritis and underwent total knee arthroplasty by a senior surgeon were included in this study. One hundred patients underwent TKA using the hand-held navigation system, while the other 100 patients underwent TKA using the conventional technique. The primary outcomes of this study were the overall alignment of the lower limb and the position of the components. This was determined radiologically using the: (1) Hip-Knee-Ankle angle (HKA) for lower limb alignment; (2) Coronal Femoral-Component angle (CFA); and (3) Coronal Tibia-Component angle (CTA) for component position. Normal alignment was taken as 180A degrees A +/- 3A degrees for the HKA and 90A degrees A +/- 3A degrees for both the CFA and CTA. For the CFA, the proportion of outliers was 7 and 17% in the hand-held navigation and conventional group, respectively (p = 0.030). For the HKA and CTA, there was no difference in the proportion of outliers between the two groups. The duration of surgery was 73 +/- 9 min and 87 +/- 15 min in the hand-held navigation and conventional group, respectively (p < 0.001). This hand-held navigation system is an effective intraoperative tool for reducing the proportion of outliers for femoral implant placement as well as the duration of surgery. The authors conclude that it can be considered for use to check femoral implant placement intra-operatively. III.
引用
收藏
页码:381 / 386
页数:6
相关论文
共 50 条
  • [41] Comparing an imageless hand-held robotic-assisted system versus conventional technique for component positioning and early clinical outcomes in total knee arthroplasty
    Hasegawa, Masahiro
    Hattori, Yoshio
    Naito, Yohei
    Tone, Shine
    Sudo, Akihiro
    INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2024, 20 (01)
  • [42] Alignment accuracy and functional outcomes between hand-held navigation and conventional instruments in TKA: a randomized controlled trial
    Narkbunnam, Rapeepat
    Pornrattanamaneewong, Chaturong
    Ruangsomboon, Pakpoom
    Chareancholvanich, Keerati
    BMC MUSCULOSKELETAL DISORDERS, 2022, 23 (01)
  • [43] NAVIGATION IN TOTAL KNEE ARTHROPLASTY: IS THERE ANY ADVANTAGE?
    Carvalho Matos, Luiz Felipe
    Quintas Alves, Andre Lopes
    Sobreiro, Alberto Lima
    Giordano, Marcos Noberto
    Pires de Albuquerque, Rodrigo Satamini
    Pires Carvalho, Antnio Carlos
    ACTA ORTOPEDICA BRASILEIRA, 2011, 19 (04): : 184 - 188
  • [44] Current state of the art in total knee arthroplasty computer navigation
    Picard, Frederic
    Deep, Kamal
    Jenny, Jean Yves
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2016, 24 (11) : 3565 - 3574
  • [45] Pinless navigation in total knee arthroplasty: Navigation reduced by the maximum?
    Maderbacher, Guenther
    Schaumburger, Jens
    Keshmiri, Armin
    Barthel, Magdalena
    Springorum, Hans-Robert
    Craiovan, Benjamin
    Grifka, Joachim
    Baier, Clemens
    INTERNATIONAL ORTHOPAEDICS, 2015, 39 (03) : 455 - 460
  • [46] A meta-analysis of unicompartmental knee arthroplasty revised to total knee arthroplasty versus primary total knee arthroplasty
    Sun, Xuedong
    Su, Zheng
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2018, 13
  • [47] Accuracy of a novel extramedullary femoral alignment guide system in primary total knee arthroplasty
    Matsumoto, Kazu
    Mori, Nobuyuki
    Ogawa, Hiroyasu
    Akiyama, Haruhiko
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2015, 135 (12) : 1743 - 1748
  • [48] Cadaveric results of an accelerometer based, extramedullary navigation system for the tibial resection in total knee arthroplasty
    Nam, Denis
    Dy, Christopher J.
    Cross, Michael B.
    Kang, Michael N.
    Mayman, David J.
    KNEE, 2012, 19 (05) : 617 - 621
  • [49] Evaluation of Total Knee Arthroplasty Performed With and Without Computer Navigation: A Bilateral Total Knee Arthroplasty Study
    Johnson, Derek R.
    Dennis, Douglas A.
    Kindsfater, Kirk A.
    Kim, Raymond H.
    JOURNAL OF ARTHROPLASTY, 2013, 28 (03) : 455 - 458
  • [50] Clinical outcomes of computer-assisted total knee arthroplasty using pinless navigation
    Jiang, Lei
    Chen, Jerry Yongqiang
    Chong, Hwei-Chi
    Chia, Shi-Lu
    Lo, Ngai-Nung
    Yeo, Seng Jin
    JOURNAL OF ORTHOPAEDIC SURGERY, 2017, 25 (01):