The accuracy of a hand-held navigation system in total knee arthroplasty

被引:5
作者
Loh, Bryan [1 ]
Chen, Jerry Yongqiang [1 ]
Yew, Andy Khye Soon [1 ]
Pang, Hee Nee [1 ]
Tay, Darren Keng Jin [1 ]
Chia, Shi-Lu [1 ]
Lo, Ngai Nung [1 ]
Yeo, Seng Jin [1 ]
机构
[1] Singapore Gen Hosptial, Dept Orthopaed Surg, 20 Coll Rd, Singapore 169856, Singapore
关键词
Hand-held navigation; Total knee arthroplasty; Lower limb alignment; Implant placement; RANDOMIZED CONTROLLED-TRIAL; COMPUTER NAVIGATION; CORONAL ALIGNMENT; TIBIAL RESECTION; NO DIFFERENCE; REPLACEMENT; FRACTURE; OUTCOMES; SURGERY;
D O I
10.1007/s00402-016-2612-8
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
This study aims to evaluate the effectiveness of a new hand-held navigation system. The authors of this study hypothesize that this navigation system will improve overall lower limb alignment and implant placement without causing a delay in surgery. Two hundred consecutive patients diagnosed with tricompartmental osteoarthritis and underwent total knee arthroplasty by a senior surgeon were included in this study. One hundred patients underwent TKA using the hand-held navigation system, while the other 100 patients underwent TKA using the conventional technique. The primary outcomes of this study were the overall alignment of the lower limb and the position of the components. This was determined radiologically using the: (1) Hip-Knee-Ankle angle (HKA) for lower limb alignment; (2) Coronal Femoral-Component angle (CFA); and (3) Coronal Tibia-Component angle (CTA) for component position. Normal alignment was taken as 180A degrees A +/- 3A degrees for the HKA and 90A degrees A +/- 3A degrees for both the CFA and CTA. For the CFA, the proportion of outliers was 7 and 17% in the hand-held navigation and conventional group, respectively (p = 0.030). For the HKA and CTA, there was no difference in the proportion of outliers between the two groups. The duration of surgery was 73 +/- 9 min and 87 +/- 15 min in the hand-held navigation and conventional group, respectively (p < 0.001). This hand-held navigation system is an effective intraoperative tool for reducing the proportion of outliers for femoral implant placement as well as the duration of surgery. The authors conclude that it can be considered for use to check femoral implant placement intra-operatively. III.
引用
收藏
页码:381 / 386
页数:6
相关论文
共 50 条
  • [31] Evaluation of accuracy of an electromagnetic computer-assisted navigation system in total knee arthroplasty
    Graydon, A. J.
    Malak, S.
    Anderson, I. A.
    Pitto, R. P.
    INTERNATIONAL ORTHOPAEDICS, 2009, 33 (04) : 975 - 979
  • [32] Intraoperative validation of bone cut accuracy of a pinless smart touch-screen navigation system device in total knee arthroplasty
    Ulivi, Michele
    Orlandini, Luca Claudio
    Meroni, Valentina
    Castoldi, Daniele
    Lombardo, Michele Davide Maria
    Peretti, Giuseppe M.
    INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2019, 15 (05)
  • [33] Predictability of implant sizes during cruciate-retaining total knee arthroplasty using an image-free hand-held robotic system
    Eachempati, Krishna Kiran
    Parameswaran, Apurve
    Apsingi, Sunil
    Ponnala, Vinay Kishore
    Agrawal, Shashwat
    Sheth, Neil P.
    JOURNAL OF ROBOTIC SURGERY, 2024, 18 (01)
  • [34] Unsatisfactory Accuracy as Determined by Computer Navigation of VISIONAIRE Patient-Specific Instrumentation for Total Knee Arthroplasty
    Lustig, Sebastien
    Scholes, Corey J.
    Oussedik, Sam I.
    Kinzel, Vera
    Coolican, Myles R. J.
    Parker, David A.
    JOURNAL OF ARTHROPLASTY, 2013, 28 (03) : 469 - 473
  • [35] Accuracy of Computed Tomography-Based Navigation-Assisted Total Knee Arthroplasty: Outlier Analysis
    Miyasaka, Teruyuki
    Kurosaka, Daisaburo
    Saito, Mitsuru
    Omori, Toshiyuki
    Ikeda, Ryo
    Marumo, Keishi
    JOURNAL OF ARTHROPLASTY, 2017, 32 (01) : 47 - 52
  • [36] Accuracy of different navigation systems for femoral and tibial implantation in total knee arthroplasty: a randomised comparative study
    Saiki, Yoshitomo
    Ojima, Tomohiro
    Kabata, Tamon
    Hayashi, Seigaku
    Tsuchiya, Hiroyuki
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2021, 141 (12) : 2267 - 2276
  • [37] Development of an imageless navigation system for total knee arthroplasty
    Su Yingying
    Wang Chengtao
    Qi Yuanshuai
    Yan Shiju
    Gu Lixu
    2005 27TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2005, : 6060 - 6063
  • [38] Comparison of iASSIST Navigation System with Conventional Techniques in Total Knee Arthroplasty: A Systematic Review and Meta-Analysis of Radiographic and Clinical Outcomes
    Li, Jun-tan
    Gao, Xiang
    Li, Xu
    ORTHOPAEDIC SURGERY, 2019, 11 (06) : 985 - 993
  • [39] Radiological outcomes of pinless navigation in total knee arthroplasty: a randomized controlled trial
    Chen, Jerry Yongqiang
    Chin, Pak Lin
    Li, Zongxian
    Yew, Andy Khye Soon
    Tay, Darren Keng Jin
    Chia, Shi-Lu
    Ngai Nung Lo
    Yeo, Seng Jin
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2015, 23 (12) : 3556 - 3562
  • [40] Influence of navigation system updates on total knee arthroplasty
    Inui H.
    Taketomi S.
    Nakamura K.
    Takei S.
    Takeda H.
    Tanaka S.
    Nakagawa T.
    Sports Medicine, Arthroscopy, Rehabilitation, Therapy & Technology, 5 (1):