The accuracy of a hand-held navigation system in total knee arthroplasty

被引:5
|
作者
Loh, Bryan [1 ]
Chen, Jerry Yongqiang [1 ]
Yew, Andy Khye Soon [1 ]
Pang, Hee Nee [1 ]
Tay, Darren Keng Jin [1 ]
Chia, Shi-Lu [1 ]
Lo, Ngai Nung [1 ]
Yeo, Seng Jin [1 ]
机构
[1] Singapore Gen Hosptial, Dept Orthopaed Surg, 20 Coll Rd, Singapore 169856, Singapore
关键词
Hand-held navigation; Total knee arthroplasty; Lower limb alignment; Implant placement; RANDOMIZED CONTROLLED-TRIAL; COMPUTER NAVIGATION; CORONAL ALIGNMENT; TIBIAL RESECTION; NO DIFFERENCE; REPLACEMENT; FRACTURE; OUTCOMES; SURGERY;
D O I
10.1007/s00402-016-2612-8
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
This study aims to evaluate the effectiveness of a new hand-held navigation system. The authors of this study hypothesize that this navigation system will improve overall lower limb alignment and implant placement without causing a delay in surgery. Two hundred consecutive patients diagnosed with tricompartmental osteoarthritis and underwent total knee arthroplasty by a senior surgeon were included in this study. One hundred patients underwent TKA using the hand-held navigation system, while the other 100 patients underwent TKA using the conventional technique. The primary outcomes of this study were the overall alignment of the lower limb and the position of the components. This was determined radiologically using the: (1) Hip-Knee-Ankle angle (HKA) for lower limb alignment; (2) Coronal Femoral-Component angle (CFA); and (3) Coronal Tibia-Component angle (CTA) for component position. Normal alignment was taken as 180A degrees A +/- 3A degrees for the HKA and 90A degrees A +/- 3A degrees for both the CFA and CTA. For the CFA, the proportion of outliers was 7 and 17% in the hand-held navigation and conventional group, respectively (p = 0.030). For the HKA and CTA, there was no difference in the proportion of outliers between the two groups. The duration of surgery was 73 +/- 9 min and 87 +/- 15 min in the hand-held navigation and conventional group, respectively (p < 0.001). This hand-held navigation system is an effective intraoperative tool for reducing the proportion of outliers for femoral implant placement as well as the duration of surgery. The authors conclude that it can be considered for use to check femoral implant placement intra-operatively. III.
引用
收藏
页码:381 / 386
页数:6
相关论文
共 50 条
  • [1] The accuracy of a hand-held navigation system in total knee arthroplasty
    Bryan Loh
    Jerry Yongqiang Chen
    Andy Khye Soon Yew
    Hee Nee Pang
    Darren Keng Jin Tay
    Shi-Lu Chia
    Ngai Nung Lo
    Seng Jin Yeo
    Archives of Orthopaedic and Trauma Surgery, 2017, 137 : 381 - 386
  • [2] Accuracy of a hand-held surgical navigation system for tibial resection in total knee arthroplasty
    Bugbee, William D.
    Kermanshahi, Arash Y.
    Munro, Michelle M.
    McCauley, Julie C.
    Copp, Steven N.
    KNEE, 2014, 21 (06): : 1225 - 1228
  • [3] Hand-held navigation may improve accuracy in minimally invasive total knee arthroplasty: a prospective randomized controlled trial
    Thiengwittayaporn, Satit
    Fusakul, Yupadee
    Kangkano, Nunnapat
    Jarupongprapa, Chanintorn
    Charoenphandhu, Narattaphol
    INTERNATIONAL ORTHOPAEDICS, 2016, 40 (01) : 51 - 57
  • [4] Hand-held navigation may improve accuracy in minimally invasive total knee arthroplasty: a prospective randomized controlled trial
    Satit Thiengwittayaporn
    Yupadee Fusakul
    Nunnapat Kangkano
    Chanintorn Jarupongprapa
    Narattaphol Charoenphandhu
    International Orthopaedics, 2016, 40 : 51 - 57
  • [5] Less outliers in pinless navigation compared with conventional surgery in total knee arthroplasty
    Chen, Jerry Yongqiang
    Chin, Pak Lin
    Tay, Darren Keng Jin
    Chia, Shi-Lu
    Lo, Ngai Nung
    Yeo, Seng Jin
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2014, 22 (08) : 1827 - 1832
  • [6] Current Role of Computer Navigation in Total Knee Arthroplasty
    Jones, Christopher W.
    Jerabek, Seth A.
    JOURNAL OF ARTHROPLASTY, 2018, 33 (07): : 1989 - 1993
  • [7] Learning curve for robotic assisted total knee arthroplasty: our experience with imageless hand-held Navio system
    Vaidya, Narendra
    Gadekar, Anup
    Agrawal, Varun O.
    Jaysingani, Tanmay N.
    JOURNAL OF ROBOTIC SURGERY, 2023, 17 (02) : 393 - 403
  • [8] Total knee replacement with an accelerometer-based, hand-held navigation system improves knee alignment: reliable in all patients
    Perico, Diego Alarcon
    Perez, Sergio F. Guarin
    Lee, Sheng-Hsun
    Warne, Christopher N.
    Hadley, Matthew
    Taunton, Michael J.
    Sierra, Rafael J.
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2024, 144 (09) : 4125 - 4132
  • [9] Computer-assisted stereotaxic navigation improves the accuracy of mechanical alignment and component positioning in total knee arthroplasty
    Liow, Ming Han Lincoln
    Goh, Graham Seow-Hng
    Pang, Hee-Nee
    Tay, Darren Keng Jin
    Lo, Ngai Nung
    Yeo, Seng Jin
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2016, 136 (08) : 1173 - 1180
  • [10] Comparative Study of Pinless Navigation System versus Conventional Instrumentation in Total Knee Arthroplasty
    Pawar, Prashant
    Naik, Lokesh
    Sahu, Dipit
    Bagaria, Vaibhav
    CLINICS IN ORTHOPEDIC SURGERY, 2021, 13 (03) : 358 - 365