Iodine Sensing by AgI and AgI1-xClx

被引:3
作者
Clinsha, P. C. [1 ]
Gnanasekar, K. I. [1 ]
Jayaraman, V. [1 ]
Gnanasekaran, T. [2 ]
机构
[1] Indira Gandhi Ctr Atom Res, Chem Grp, Mat Chem Div, Kalpakkam 603102, Tamil Nadu, India
[2] Indira Gandhi Ctr Atom Res, Kalpakkam 603102, Tamil Nadu, India
关键词
AgI; AgI1-xClx; Iodine sensor; Potentiometric sensor; SENSOR; ION; CARRIER; SYSTEM; CS;
D O I
10.1002/elan.201400248
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Compositions of nominal formula, AgI1-xClx (x= 0-0.25) were prepared by soft chemical method. The synthesized compositions were characterized by various physicochemical techniques. The studies revealed the formation of solid solution of AgCl in AgI up to 5 mol%. The composition AgI0.95Cl0.05 exhibited marginally higher conductivity than AgI. Electrochemical sensors were assembled using AgI and AgI0.95Cl0.05. Iodine sensing properties of these two potentiometric sensors were elucidated. Preliminary results show that I-2 can be sensed down to similar to 10 vppm.
引用
收藏
页码:2398 / 2402
页数:5
相关论文
共 16 条
[1]  
BAZAN JC, 1982, SOLID STATE IONICS, V6, P171, DOI 10.1016/0167-2738(82)90084-4
[2]  
BURLEY G, 1963, AM MINERAL, V48, P1266
[3]  
Chandra S., 1981, SUPERIONIC SOLIDS PR
[4]   Polymeric films based on long-chain acetylenes as sensors for iodine vapour [J].
Dultsev, F. N. .
SENSORS AND ACTUATORS B-CHEMICAL, 2008, 129 (01) :171-175
[5]   Chemiluminescence determination of iodide and/or iodine using a luminol-hexadecyltrimethylammonium chloride reversed micelle system following on-line oxidation and extraction [J].
Fujiwara, T ;
Mohammadzai, IU ;
Inoue, H ;
Kumamaru, T .
ANALYST, 2000, 125 (04) :759-763
[6]   Iodide-selective electrodes based on bis[N(2-methyl-phenyl) 4-nitro-thiobenzamidato]mercury(II) and bis[N-phenyl 3,5-dinitro-thiobenzamidato]mercury(II) carriers [J].
Ghaedi, M ;
Shojaie, AF ;
Montazerozohori, M ;
Karami, B ;
Gharaghani, S .
ELECTROANALYSIS, 2005, 17 (19) :1746-1754
[7]   Superionics: crystal structures and conduction processes [J].
Hull, S .
REPORTS ON PROGRESS IN PHYSICS, 2004, 67 (07) :1233-1314
[8]   A Selective Iodide Ion Sensor Electrode Based on Functionalized ZnO Nanotubes [J].
Ibupoto, Zafar Hussain ;
Khun, Kimleang ;
Willander, Magnus .
SENSORS, 2013, 13 (02) :1984-1997
[9]  
Ihara S., 1985, PHYS STATUS SOLIDI B, V7, P131
[10]   Conjugated carbazole dimer as fluorescence carrier for preparation of iodine-sensitive chemical sensor [J].
Jiao, CX ;
Qi, S ;
Huan, SY ;
Shen, GL ;
Yu, RQ .
ANALYTICA CHIMICA ACTA, 2005, 528 (02) :229-234